Page 68

Chapter 4

Basic Functions 3. Set the serial No. direction. Press the ▼ or ▲ key to select “09 No. Direction”. Press the [ENTER] key, and set the serial No. direction using the ▼ and ▲ keys. Then, press the [ENTER] key to save the setting. 09 1 )

No . D i r e c t i on Re v e r s e

4. Set the serial No. start digit. Press the ▼ or ▲ key to select “10 Start Digit”. Press the [ENTER] key, and set the start digit using the ▼ and ▲ keys. Then, press the [ENTER] key to save the setting. 10

S t a r t

D i g i t 6

5. Set the serial No. effective digits. Press the ▼ or ▲ key to select “11 Max Digits”. Press the [ENTER] key, and set the effective digits using the ▼ and ▲ keys. Then, press the [ENTER] key to save the setting.

4

11

Ma x

D i g i t 3

6. Set the serial No. increment. Press the ▼ or ▲ key to select “12 No. Change”. Press the [ENTER] key, and set the increment using the ▼ and ▲ keys. Then, press the [ENTER] key to save the setting. 12

No .

Change +3

7. Set the serial No. protect. Press the ▼ or ▲ key to select “13 No. Protect”. Press the [ENTER] key, and set the serial No. protect using the ▼ and ▲ keys. Then, press the [ENTER] key to save the setting. 13 0 )

No . P r o t e c t Re s e t

8. Exit set mode. Press the [CANCEL] key twice to exit set mode.

PRESET

TIM 1 TIM 2 4 3 2 1 OUT

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

PRGRAM

MONITOR

8 7 6 5 OK 10 9 NG

PRESET

KEYENCE

CANCEL

ENTER

BL-V35E

Note: When the operation mode is not set to “Serial No.”, the setting parameters “09 No. Direction”, “10 Start Digit”, “11 Max Digits”, “12 No. Change” and “13 No. Protect” are not displayed. This completes setting of serial No. target digits.

58

Page 69

Chapter 4

Basic Functions

4.4.4 Operation using the serial No. check function Operation using the serial No. check function is performed as follows. 1. When the BL-V35E is started up, “Serial No.” appears on the LCD display. Read y Ve r i f y

Se r i a l

No

2. When a bar code is read, the serial No. start value is saved. OK is output, the data to be read next is displayed in the upper line of the LCD display, and the counter value of the readout serial No. data is displayed in the lower line. • If data located in the serial No. target digits of the readout data is incorrect (when a character other than a number is located in a serial No. target digit, for example), NG is output and the start value is not saved. Read a correct bar code. When serial No. target digits are correct Data to be read next

When serial No. target digits are not correct Readout data Counter value is not displayed.

Counter value

PRESET PRESET

1 TIM 1 TIM 2

TIM 1 TIM 2

ABCDE FG

4 3 2 1

AB0 0 0 0 2 (

4 3 2 1 OUT

Parallel output

–

Parallel output “OK”

1 )

8 7 6 5

“NG”

OUT 8 7 6 5 OK 10 9 NG

OK 10 9 NG

PRESET PRESET

CANCEL

ENTER

CANCEL

ENTER

KEYENCE

KEYENCE

“-” is displayed.

“1” is displayed.

Note 1: When the power is turned on, the serial No. data is empty. Accordingly, when OK is output for the first readout data, it means that the serial No. target digits of the readout data are correct. If the serial No. target digits of the readout data are incorrect, the entire bar code becomes NG. Note 2: When the output is OK, the data to be read next (next serial No. data) is displayed on the LCD display. The readout data is not displayed. 3. Read serial Nos. one by one to check them. Every time the readout data is a serial No., OK is output. When the readout data is not a serial No., NG is output, “Err” is displayed on the preset No. indication LED, and the readout data itself is displayed on the LCD display. When a correct serial No. is read after that, OK is output and the BL-V35E waits for the next serial No. • When the [CLEAR] key is pressed while “Err” is displayed, the serial No. data to be read next is displayed. •

The available parallel outputs are OK and NG only. For details, see p. 45.

When the readout serial No. is OK Data to be read next Counter value

Readout data

Parallel output

PRESET

1 TIM 1 TIM 2

When the readout serial No. is NG

Err TIM 1 TIM 2

AB 0 0 0 0 3

4 3 2 1

(

OUT

2 )

8 7 6 5

“OK”

Parallel output

PRESET

AB1 2 0 0 0 (

4 3 2 1 OUT

1 )

8 7 6 5

OK

“NG”

OK

10 9

10 9

NG

NG

PRESET

KEYENCE

CANCEL

PRESET

ENTER

CANCEL ENTER

KEYENCE

“1” is displayed.

“Err” is displayed.

59

4

Page 70

Chapter 4

Basic Functions ■ Key operations available during serial No. check ▼ key

: Decreases the serial No. by the increment value. (The output is not turned on.)

▲ key

: Increases the serial No. by the increment value. (The output is not turned on.)

[PRESET] key : Clears the serial No. data to empty status. [CANCEL] key : Restarts serial No. check from the start value first saved when the serial No. was empty. [ENTER] key

: Outputs OK, and increases the serial No. by the increment value.

Note: The counter value indicates the number of bar codes checked. The counter value increases by “1” each time even when the serial No. increment is set to a number other than “+1”.

4

60

Page 71

Chapter 4

4.5

Basic Functions

Key Input Procedure This section describes how to enter preset mode, as well as reference data for using the numeric keypad.

Procedure 1. Press the [DATA] key. The numeric keypad becomes available. The LED above the [DATA] key illuminates.

PRESET

TIM 1 TIM 2

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

4 3 2 1 OUT 8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

KEYENCE

PROGRAM MONITOR

BL-V35E

When the [DATA] key is pressed and held for 1 second, data can be entered from the last digit of the preset data currently displayed. 4906780756458

Note: When the [DATA] key is pressed again, the data being entered is deleted. 2. Enter numbers using the numeric keypad. In this status, numbers can be entered. To delete the last number entered, press the [BACK SPACE] key. [BACK SPACE] key

PRESET

TIM 1 TIM 2

PRESET No.

DATA

SHIFT SYMBOL

OPTOIN

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

4 9 0 6

4 3 2 1 OUT 8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

KEYENCE

PROGRAM MONITOR

BL-V35E

Numbers can be entered

3. To enter letters or symbols, first press the [SHIFT SYMBOL] key. When the [SHIFT SYMBOL] key is pressed, the LED above it illuminates.

PRESET

TIM 1 TIM 2

4906

4 3 2 1 OUT

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

8 7 6 5 OK 10 9 NG

PRESET

KEYENCE

CANCEL

ENTER

PROGRAM MONITOR

BL-V35E

61

4

Page 72

Chapter 4

Basic Functions 4. Enter characters. When the ▲8 or 2 key is pressed, various characters are displayed in turn. • When the [CLEAR] key is pressed, the characters “Aa*!?_(space)0"°-” are displayed in this order. It is convenient to display the character nearest to a desired one using the 2 CLEAR key, and then select the desired character using the or ▲8 key (➮ p. 63). •

When the 6 key is pressed, the cursor shifts to the next digit. When the 4 key is pressed, the cursor shifts to the previous digit to allow modifications. Change of character type

To the previous digit

PRESET

TIM 1 TIM 2

4906B

4 3 2 1 OUT

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

KEYENCE

4

PROGRAM MONITOR

BL-V35E

Change of character type

To the next digit key to finish character input. 5. Press the The LED above the [SHIFT SYMBOL] key turns off, and the BL-V35E waits for input of numbers.

PRESET

TIM 1 TIM 2

4906B

4 3 2 1 OUT

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

KEYENCE

PROGRAM MONITOR

BL-V35E

6. Finish input using the numeric keypad. key is pressed again, the LED above the [DATA] key turns off. When the In RUN mode, when data has been entered using the numeric keypad and the [ENTER] key is pressed, the parallel output is given in response to the entered data. The LED above the [DATA] key turns off.

PRESET

TIM 1 TIM 2

4906B

4 3 2 1 OUT

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

8 7 6 5 OK 10 9 NG

PRESET

KEYENCE

CANCEL

ENTER

PROGRAM MONITOR

BL-V35E

Note: While the LED above the [DATA] key is illuminated, the data entered using the numeric keypad is not yet saved.

62

Page 73

Chapter 4

Basic Functions

■ List of characters that can be entered in the BL-V35E The following characters can be entered while the [SHIFT SYMBOL] key is in effect. By pressing the [CLEAR] key while characters are being entered, the character type can be changed. It is convenient to press the [CLEAR] key to display the character nearest to a desired one. When the quence.

2 key is pressed, characters are displayed in the following se-

Display sequence → ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz – ”°"#$%&'()*+,-./[¥]@^_:;<=>{|} 0123456789?!

When the [CLEAR] key is pressed, the character type is switched in the following sequence. Aa*!?_0"° - 63

4

Page 74

Chapter 4

4.6

Basic Functions

Parallel Inputs This section describes parallel inputs that allow an external unit to perform the operations available using the main keys of the BL-V35E. Parallel inputs are used to allow an external unit to perform the operations available using the main keys ([PRESET], ▼ . ▲ , [CANCEL] and [ENTER]) of the BL-V35E. These keys correspond to parallel inputs as follows. [PRESET] . IN5 ▼ ............ IN4 ▲ ............ IN3 [CANCEL] .. IN2 [ENTER] .... IN1 Note: Only IN5 offers a different operation, and functions as follows. Operation by key input

4

PRESET

PRESET Preset mode

Operation by IN5

■ Entering the preset data using parallel inputs When entering the preset data using parallel inputs, enter as follows.

IN5

Read of bar code Preset No. 1

2

3

■ Selecting the preset data while the preset-active function is used When selecting the preset data while the preset-active function is used, use the following procedure.

IN5 IN4 IN3 Preset No.

2

3

4

5

5

A circled preset No. indicates the selected number.

64

4

3

3