Page 7
Parts and Functions BL-700 6Transmitter/receiver 1LASER ON LED 2STABILITY LED
LASER ON
3OK/NG LED
STB OK/NG TIMING
4TIMING LED 5TEST switch
TEST
BL-700
7 Cable
No. Name
Function
1
LASER ON LED
Lit when laser beams are emitted.
2
STABILITY LED
Displays the reading stability and the BL-700 operating status. ➮ See P. 64 to P. 65
3
OK/NG LED
• When OK output is ON: The green LED lights. • When NG output is ON: The red LED lights.
4
TIMING LED
Lit when trigger input is ON.
5
TEST SWITCH
This switch allows the following operations: • Start the test mode. • Pressing the switch once reads the bar code once. • Sets the communication protocol to the initial values when sending the settings. ➮ See P.75
6
Transmitter/receiver
Window to emit laser beams and receive reflected lights.
7
Cable
Cable length is 1.8 m.
• Reset the error status.➮ See P.45 vi
Page 8
BL-U1
1 OK/NG LED 2 TIMING LED 3 Communication status indicator LEDs 4 POWER LED 5 I/O terminal block
6 Power switch 7 Power supply cable (2 m)
8 RS-232C port 9 READER port 0 DIP switches
No. Name
Function
1
OK/NG LED
• When OK output is ON: The green LED lights.
2
TIMING LED
3
Communication status • Allows you to monitor the communication status of the RS-232C port. indicator LEDs • The SD, RD, RS and CS indicators are provided in this order from the top.
4
POWER LED
Lit when power is ON.
5
I/O terminal block
Includes the trigger input terminal, OK/NG output terminals, RS-422A terminal and RS-485 terminal.
6
Power switch
Turns the power ON/OFF.
7
Power supply cable (2 m)
Use a 100 to 240 VAC (50/60 Hz) power supply.
8
RS-232C port
Connect a personal computer to this port. This port is unused in multi-drop link mode.
9
READER port
Connect the BL series to this port.
0
DIP switches
Switches the communication port, and turns the terminator ON/OFF.
• When NG output is ON: The red LED lights. Lit when trigger input is ON.
Note: This product does not comply with EC directives.
vii
Page 9
BL-U2
1 READER port
READER
5 POWER LED
POWER
2 TRIGGER input terminals
SD
6 Communication status indicator LEDs
RD
3 OK/NG output terminals
RS-232C
BL-U2
4 Power supply terminals
No. Name
7 RS-232C port
Function
1
READER port
Connects to a BL series bar code reader.
2
TRIGGER
Connect to a sensor for input terminals trigger input.
3
OK/NG output terminals
Output OK/NG signals.
4
Power supply terminals
Connect to a 24 VDC power supply.
5
POWER LED
Turns on when the power is on.
6
Communication status indicator LEDs
Indicate the communication status of the RS-232C.
7
RS-232C port
Connects to a personal computer, etc.
1 READER port
N-42
READER
POWER
2 TRIGGER input terminals 3 OK/NG output terminals
SD
7 POWER LED
RD
ON OFF
6 Communication status indicator LEDs 5 Terminator switch
4 Power supply terminals
No. Name
Function
1
READER port
Connects to a BL series or RS-232C equipment.
2
TRIGGER input terminals
Connect to a sensor for trigger input.
3
OK/NG output terminals
Output OK/NG signals.
4
Power supply/ interface terminal block
The 24 VDC power supply terminal and communication interface (RS-422A or RS-485) terminal are provided.
5
Terminator switch
Turns ON/OFF the terminator resistor: 100 Ω).
6
Communication status
Indicates the RS-422A or RS-485 communication status.
7
POWER LED
Lights when the power is turned ON viii