Page 154

Appendices

Appendix L Setup Parameter List Fill in the specified data for each parameter. Copy the list for daily operation. ■ Bar code setup Setup parameter

Code 1

Code type

(

Maximum number of digits

(

)

(

)

(

)

(

)

Minimum number of digits

(

)

(

)

(

)

(

)

Send start/stop character (CODE39, Coda bar)

■ Don’t send ■ Send

■ Don’t send ■ Send

Start/stop character type (Coda bar)

■ Lowercase ■ Uppercase

■ Lowercase ■ Lowercase ■ Lowercase ■ Uppercase ■ Uppercase ■ Uppercase

Test check digit (CODE39, Coda bar, ITF)

■ Don’t test ■ Test

■ Don’t test ■ Test

Check digit type (Coda bar)

(

Send check digit (CODE39, Coda bar, ITF)

■ Don’t send ■ Send

Read EAN (More than one can be selected.)

■ EAN 13-digit ■ EAN 13-digit ■ EAN 13-digit ■ EAN 13-digit ■ EAN 8-digit ■ EAN 8-digit ■ EAN 8-digit ■ EAN 8-digit ■ UPC-E ■ UPC-E ■ UPC-E ■ UPC-E

)

)

(

Code 3 )

(

(

Code 4 )

■ Don’t send ■ Send

■ Don’t test ■ Test )

■ Don’t send ■ Send

(

(

)

■ Don’t send ■ Send

■ Don’t test ■ Test )

■ Don’t send ■ Send

(

)

■ Don’t send ■ Send

Number of output digits of UPC-A

■ 13 digits ■ 12 digits

■ 13 digits ■ 12 digits

■ 13 digits ■ 12 digits

■ 13 digits ■ 12 digits

Add “0” to UPC-E system code

■ Don’t add ■ Add

■ Don’t add ■ Add

■ Don’t add ■ Add

■ Don’t add ■ Add

CODE Check double ■ Don’t check 128 character start pattern ■ Check

■ Don’t check ■ Check

■ Don’t check ■ Check

■ Don’t check ■ Check

■ Don’t set ■ Set

■ Don’t set ■ Set

■ Don’t set ■ Set

■ Don’t set ■ Set

■ Forward ■ Backward

■ Forward ■ Backward

■ Forward ■ Backward

■ Forward ■ Backward

Number of effective digits

(

)

(

)

(

)

(

)

Start digit

(

)

(

)

(

)

(

)

Set specified-digit output function Specified direction

Set label reading in the specified direction Specified direction

■ Don’t set ■ Set

■ Don’t set ■ Set

■ Don’t set ■ Set

■ Don’t set ■ Set

■ Normal ■ Reverse

■ Normal ■ Reverse

■ Normal ■ Reverse

■ Normal ■ Reverse

141

Appendices

Code 2

Page 155

Appendices ■ Main setup Read mode

■ Single

Data send trigger

■ After reading ■ After trigger OFF

■ Multi 1 ■ Multi 2

Double reading prevention time

(

)

■ Multi 3 Decode match count

(

)

Data addition function (more than one can be selected)

■ Decode count

■ Label orientation ■ Code type

Reading error code

(

■ Scan count (available only when decode count is added)

)

■ Trigger Input Setup

Appendices

Trigger input

Selection method

■ Level signal trigger

One-shot signal trigger time

(

Input time

■ 2 ms

■ 10 ms

Input polarity

■ N.O.

■ N.C.

Start test mode at trigger input ON

■ Don’t start ■ Start

Start test mode at power ON

■ Don’t start ■ Start

Command Trigger ON command

■ One-shot signal trigger

)

■ Reading rate ■ Tact measurement measurement

■ Reading rate ■ Tact measurement measurement

(

)

Trigger OFF command (

)

■ Comm Settings-1 Baud rate

(

Data length

■ 7 bits ■ 8 bits

) ■ Stop bits

■ 1 bit ■ 2 bits

■ Parity

(

)

RTS/CTS protocol ■ Don’t use ■ Use Multi-drop link

■ Don’t use ■ Use

142

■ ID No.

■ None ■ Even ■ Odd

Page 156

Appendices ■ Communication parameters 2 PLC link ■ Don’t use Protocol

■ Use

■ Non-procedure ■ PASS/RTRY ■ ACK/NAK

Header

■ None ■ Specify (

■ STX )

■ ESC

Delimiter

■ None ■ Specify (

■ CR+LF )

■ ETX

Checksum

■ Don’t add

■ Add

PLC type

■ SYSMAC-C ■ KV

■ MELSEC-A

PLC trigger area

■ Don’t use

■ Use

DM head address

(

) 00

PLC station/Unit No.

(

)

File register

■ Don’t use

File register block No.

(

■ Use

)

Delimiter character

(

)

Semi-delimiter

(

)

Appendices

■ Communication character

■ Utilities Display STABILITY LEDs

■ Don’t display

■ Display

OK/NG output ON time

(

)

Preset data

(

)

143

Page 157

Appendices

Appendix M Default Setting List ■ Bar code setup Parameter

Code 1

Code 2

Code 3

Code 4

Code type

CODE39

Coda bar

UPC/EAN

None

Maximum number of digits

32

32

–

Minimum number of digits

03

03

–

Send start/stop character

Don’t send

Send

–

Lowercase

–

Don’t test

–

Start/stop character type Test check digit

Don’t test

Read JAN (More than one can be selected.)

All EAN 13-digit, EAN 8-digit and UPC-E are readable.

Number of output digits of UPC-A

13 digits

Add “0” to UPC-E system code

Don’t add

Set specified-digit output function

Don’t set

Don’t set

Don’t set

–

Set label reading in the specified direction

Don’t set

Don’t set

Don’t set

–

Appendices

■ Main setup Read mode

Single

Data send trigger

After reading

Decode match count

2

Data addition function

None

Reading error code

ERROR

■ Trigger input setup

144

Selection method

Level signal trigger

Input time

2 ms

Input polarity

Normal Open

Start test mode at trigger input ON

Don’t start

Start test mode at power ON

Don’t start

Trigger ON command

LON

Trigger OFF command

LOFF

Page 158

Appendices ■ Comm Settings-1 Baud rate

9600 bit/s

Data length

7 bits

Parity

Even

Stop bits

1 bit

RTS/CTS protocol

Don’t use

Multi-drop link

Don’t use

■ Comm Settings-2 PLC link

Don’t use

Protocol

Non-procedure

Header

None

Delimiter

CR

Checksum

Don’t add

■ Communication character Delimiter character

: [3A]

Semi-delimiter

, [2C]

OK/NG output ON time

500 ms

STABILITY LEDs

Don’t display

Preset data

Don’t set

Appendices

■ Utilities

145

Page 159

146

Page 160

WARRANTIES AND DISCLAIMERS: (1) KEYENCE warrants the Products to be free of defects in materials and workmanship for a period of one (1) year from the date of shipment. If any models or samples were shown to Buyer, such models or samples were used merely to illustrate the general type and quality of the Products and not to represent that the Products would necessarily conform to said models or samples. Any Products found to be defective must be shipped to KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE for inspection and examination. Upon examination by KEYENCE, KEYENCE, at its sole option, will refund the purchase price of, or repair or replace at no charge any Products found to be defective. This warranty does not apply to any defects resulting from any action of Buyer, including but not limited to improper installation, improper interfacing, improper repair, unauthorized modification, misapplication and mishandling, such as exposure to excessive current, heat, coldness, moisture, vibration or outdoors air. Components which wear are not warranted. (2) KEYENCE is pleased to offer suggestions on the use of its various Products. They are only suggestions, and it is Buyer’s responsibility to ascertain the fitness of the Products for Buyer’s intended use. KEYENCE will not be responsible for any damages that may result from the use of the Products. (3) The Products and any samples (“Products/Samples”) supplied to Buyer are not to be used internally in humans, for human transportation, as safety devices or fail-safe systems, unless their written specifications state otherwise. Should any Products/Samples be used in such a manner or misused in any way, KEYENCE assumes no responsibility, and additionally Buyer will indemnify KEYENCE and hold KEYENCE harmless from any liability or damage whatsoever arising out of any misuse of the Products/Samples. (4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED. IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST BUYER. In some jurisdictions, some of the foregoing warranty disclaimers or damage limitations may not apply. BUYER’S TRANSFER OBLIGATIONS: If the Products/Samples purchased by Buyer are to be resold or delivered to a third party, Buyer must provide such third party with a copy of this document, all specifications, manuals, catalogs, leaflets and written information provided to Buyer pertaining to the Products/Samples.

147

Page 161

Specifications are subject to change without notice. AFFILIATED COMPANIES

KEYENCE CORPORATION 1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku, Osaka, 533-8555, Japan PHONE: 81-6-6379-2211 FAX: 81-6-6379-2131

KEYENCE CORPORATION OF AMERICA PHONE: 201-930-0100 FAX: 201-930-0099

KEYENCE (MALAYSIA) SDN BHD PHONE: 03-252-2211 FAX: 03-252-2131

KEYENCE DEUTSCHLAND GmbH PHONE: 06102-36 89-0 FAX: 06102-36 89-100

KEYENCE (THAILAND) CO., LTD PHONE: 02-369-2777 FAX: 02-369-2775