Page 134

Appendices

Raster width specification

Model

Reading distance

Raster width

BL-701

200 mm

10±1 mm

BL-741

300 mm

20±2 mm

BL-781

450 mm

30±3 mm

Appendices

In raster scan mode, the BL-700 scans multiple positions of the bar code by swinging the laser beams up and down. Thus, the bar code can be read even if it has a stain or missing part. For the up-down width of raster scan (raster width), see the table below:

121

Page 135

Appendices

Appendix A.2

Reading Range Characteristics (Typical) ■ BL-700/701 Unit: mm

A

Bar code type

Narrow bar width

Reading distance

Max. readable label width

CODE39

0.15

205 to 275

210

B

CODE39

0.19

190 to 300

254

C

CODE39

0.25

175 to 325

275

D

CODE39

0.5

160 to 370

310

E

UPC/EAN1x

0.33

185 to 320

270

0

50

100

150

200

250

300

350

400 Reading distance (mm)

230 (Focal length)

200 150 100 50

185 215 210 254 270 275 310

0 50

Appendices

(Measuring conditions) • The KEYENCE standard bar code is used. • Ratio of thin bar to thick bar = 1:2.5 • Skew: 0° • Pitch: 0° • Tilt: 0°

*

100

A B E C D

150 200

Readable label width (mm)

For the reading distance measuring reference, see P.26.

Note 1: The readable label width means a bar code length including the right and left margins (quiet zones) of a bar code. Note: 2 Even if a bar code is within the above reading range, it may not be read depending on the bar code quality. Set the optimum reading position based on enough reading tests. Note 3: Normally, the reading distance should be set to 230 mm (focal length). In this case, the maximum readable label width is 215 mm (when the narrow bar width is 0.19 mm or more).

122

Page 136

Appendices ■ BL-740/741 Unit: mm

A

Bar code type

Narrow bar width

Reading distance

Max. readable label width

CODE39

0.25

360 to 440

330 350

B

CODE39

0.32

360 to 490

C

CODE39

0.5

330 to 550

430

D

CODE39

1

230 to 650

510

E

UPC/EAN1x

1 time

150 to 750

600

0

100

200

300

400

500

600

700

800 Reading distance (mm) 300

400 (Focal length) 200

100

300 340 330 350 430 510 600

0

100

200

E 360~440 A 360~490

B 330~550 C 230~650

300 Readable label width (mm)

D 150~750

Note 1: The readable label width means a bar code length including the right and left margins (quiet zones) of a bar code. Note: 2 Even if a bar code is within the above reading range, it may not be read depending on the bar code quality. Set the optimum reading position based on enough reading tests. Note 3: Normally, the reading distance should be set to 230 mm (focal length). In this case, the maximum readable label width is 215 mm (when the narrow bar width is 0.19 mm or more).

123

Appendices

(Measuring conditions) • The KEYENCE standard bar code is used. • Ratio of thin bar to thick bar = 1:2.5 • Skew: 0° • Pitch: 0° • Tilt: 0°

Page 137

Appendices ■ BL-780/781 Unit: mm Bar code type

Narrow bar width

A

CODE39

0.32

480 to 580

435

B

CODE39

0.5

320 to 870

735

C

CODE39

1.0

200 to 1100

930

D

CODE39

2.0

200 to 1200

1010

0

Reading distance

100 200 300 400 500 600 700 800 900 1000 1100 1200

Max. readable label width

Reading distance (mm) 600

500 (Focal length)

500 400 300 200 100 400 465 435 735 930 1010

0 100 200

Appendices

(Measuring conditions) • The KEYENCE standard bar code is used. • Ratio of thin bar to thick bar = 1:2.5 • Skew: 0° • Pitch: 0° • Tilt: 0°

*

300 400 A B C D

500 600

Readable label width (mm)

For the reading distance measuring reference, see P.28.

Note 1: The readable label width means a bar code length including the right and left margins (quiet zones) of a bar code. Note: 2 Even if a bar code is within the above reading range, it may not be read depending on the bar code quality. Set the optimum reading position based on enough reading tests. Note 3: Normally, the reading distance should be set to 500 mm (focal length). In this case, the maximum readable label width is 465 mm (when the narrow bar width is 0.5 mm or more).

124

Page 138

Appendices

Angular Characteristics (Typical) Model BL-700/701

BL-740/741

BL-780/781

Narrow bar width

Skew

Pitch

Tilt

0.15 mm

-70° to -20°, -5° to +55°

±35°

±50°

0.19 mm

-70° to -20°, -5° to +55°

±45°

±50°

0.25 mm

-70° to -20°, -5° to +55°

±50°

±50°

0.5 mm

-70° to -20°, -5° to +55°

±55°

±50°

0.25 mm

-70° to -20°, -5° to +55°

±35°

±30°

0.32 mm

-70° to -20°, -5° to +55°

±45°

±50°

0.5 mm

-70° to -20°, -5° to +55°

±55°

±50°

1.0 mm

-70° to -20°, -5° to +55°

±55°

±30°

0.32 mm

-60° to -20°, -5° to +45°

±20°

±15°

0.5 mm

-70° to -20°, -5° to +50°

±40°

±50°

1.0 mm

-70° to -20°, -5° to +50°

±50°

±50°

Measuring conditions • Bar code: KEYENCE standard bar code • Reading distance: 230 mm (BL-700/701) 380 mm (BL-740/741) 500 mm (BL-780/781) Note: The skew angle of -20° to -5° is the specular reflection range. In this range, bar codes cannot be read, or reading error may occur. Be sure not to mount the BL-700 series at the above skew angles. Skew

Pitch –

0°

+

+

0° –

10°

Appendices

Appendix A.3

Tilt +

0°

Laser beam

–

125

Page 139

Appendices

Appendix B BL-U1 Specifications* Model

BL-U1

Power supply for bar code reader

5 VDC±5% (1.5 A)

Power supply for sensor

12 V ±10% (300 mA)

Trigger input

Input rating

8.5 to 30 VDC, 10 mA max.

OK/NG output

Output type

NPN open-collector

Rated load

30 VDC, 100 mA

Max. OFF current

0.5 mA

Leakage current (at OFF)

0.1 mA max.

Residual voltage (at ON)

1 V max.

Interface

RS-232C, RS-422A, RS-485 multidrop (Up to 31 units can be connected. Max. cable extension: 1.2 km)

Ambient temperature

0 to 50°C (32 to 122°F), No freezing

Relative humidity

35 to 85%, No condensation

Ambient atmosphere Vibration

No dust, no corrosive gas 10 to 55 Hz, 1.5 mm double amplitude in X, Y and Z directions, 2 hours respectively 1000 V p-p, 1 µs (Power line)

Noise immunity Power supply voltage

100 to 240 VAC (50/60 Hz)

Current consumption

40 VA (100 VAC), 50 VA (240 VAC)

Weight

Appendices

Note: This product is not available in Europe.

126

Approx. 615 g (including cable)

Page 140

Appendices

Appendix C BL-U2, N-42 Specifications BL-U2

Connectable bar code reader

N-42

BL-500 series, BL-180 series, BL-700 series

Power supply for bar code reader

5 VDC ±5% (630 mA)

Trigger input

Input rating

15 to 26VDC, 10 mA max.

OK/NG output

Output type

NPN open-collector

Rated load

30 VDC, 100 mA

Maximum OFF current

1.0 mA

Leakage current (at OFF)

0.1 mA max.

Residual voltage (at ON) Interface

Ambient temperature Relative humidity Ambient atmosphere Vibration

1 V max. Conforms to EIA RS-232C.

0 to 50˚C (32 to 122°F), No freezing 35 to 85%, No condensation No dust, no corrosive gas 10 to 55 Hz, 1.5 mm double amplitude in X, Y, and Z directions, 2 hours respectively +10%

Power supply voltage Current consumption Weight

RS-422A (Maximum extension distance: 1.2 km)

24 VDC -20% 250 mA

260 mA max

Approx. 80 g

Approx. 100 g

Appendices

Model

127

Page 141

Appendices

Appendix D Dimensions ■ BL-700/701/740/741/780/781 53 (A) 28.5 ø5.8, Cable length: 1.8 m

Laser beam 10° (*)

Laser transmitter 2 - ø3.5 mounting hole

9.9

58

51.5 26.5 36

3.25

46.5

3.25

* Laser beam emission angle is 10°±0.5° from perpendicular to plane (A).

■ BL-700/701/740/741/780/781 (Mounting bracket) • Vertical scanning • Horizontal scanning

Appendices

58 6

44.5

58 6.5

6

44.5

6.5

16

16

3

3

2.5

60

60

2.5

128

52

2

2.5

52

7

Page 142

Appendices ■ BL-U2

(70) 5.5

2-ø4.5 mounting hole

43.2

5.9 5.9

55

63.2 75

5.5 (70)

21

■ N-42

(70)

Appendices

2 - ø4.5 mounting hole

5.5

43.2 55

5.9 5.9

26 63.2 75

129

Page 143

Appendices ■ BL-U1*

100 to 240 VAC (with 3-core plug)

Approx. 40

ø6.5, Cable length: 2 m

98

90 110

4 - ø5 mounting hole 150 186

Appendices

Note: BL-U1 is not available in Europe.

130

4

4

120°

91 max.

51