The text of a manual · part 17 of 19
Laser Bar Code Reader BL-700 Series User's Manual: Chapter 1 Laser Safety Precautions, pages 134 to 143
Pages 134 to 143 of 161, from Laser Bar Code Reader BL-700 Series User's Manual
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Keyence BL-700, Keyence BL-701 and Keyence BL-781
Page 134
Appendices
Raster width specification
Model
Reading distance
Raster width
BL-701
200 mm
10±1 mm
BL-741
300 mm
20±2 mm
BL-781
450 mm
30±3 mm
Appendices
In raster scan mode, the BL-700 scans multiple positions of the bar code by swinging the laser beams up and down. Thus, the bar code can be read even if it has a stain or missing part. For the up-down width of raster scan (raster width), see the table below:
121
Page 135
Appendices
Appendix A.2
Reading Range Characteristics (Typical) ■ BL-700/701 Unit: mm
A
Bar code type
Narrow bar width
Reading distance
Max. readable label width
CODE39
0.15
205 to 275
210
B
CODE39
0.19
190 to 300
254
C
CODE39
0.25
175 to 325
275
D
CODE39
0.5
160 to 370
310
E
UPC/EAN1x
0.33
185 to 320
270
0
50
100
150
200
250
300
350
400 Reading distance (mm)
230 (Focal length)
200 150 100 50
185 215 210 254 270 275 310
0 50
Appendices
(Measuring conditions) • The KEYENCE standard bar code is used. • Ratio of thin bar to thick bar = 1:2.5 • Skew: 0° • Pitch: 0° • Tilt: 0°
*
100
A B E C D
150 200
Readable label width (mm)
For the reading distance measuring reference, see P.26.
Note 1: The readable label width means a bar code length including the right and left margins (quiet zones) of a bar code. Note: 2 Even if a bar code is within the above reading range, it may not be read depending on the bar code quality. Set the optimum reading position based on enough reading tests. Note 3: Normally, the reading distance should be set to 230 mm (focal length). In this case, the maximum readable label width is 215 mm (when the narrow bar width is 0.19 mm or more).
122
Page 136
Appendices ■ BL-740/741 Unit: mm
A
Bar code type
Narrow bar width
Reading distance
Max. readable label width
CODE39
0.25
360 to 440
330 350
B
CODE39
0.32
360 to 490
C
CODE39
0.5
330 to 550
430
D
CODE39
1
230 to 650
510
E
UPC/EAN1x
1 time
150 to 750
600
0
100
200
300
400
500
600
700
800 Reading distance (mm) 300
400 (Focal length) 200
100
300 340 330 350 430 510 600
0
100
200
E 360~440 A 360~490
B 330~550 C 230~650
300 Readable label width (mm)
D 150~750
Note 1: The readable label width means a bar code length including the right and left margins (quiet zones) of a bar code. Note: 2 Even if a bar code is within the above reading range, it may not be read depending on the bar code quality. Set the optimum reading position based on enough reading tests. Note 3: Normally, the reading distance should be set to 230 mm (focal length). In this case, the maximum readable label width is 215 mm (when the narrow bar width is 0.19 mm or more).
123
Appendices
(Measuring conditions) • The KEYENCE standard bar code is used. • Ratio of thin bar to thick bar = 1:2.5 • Skew: 0° • Pitch: 0° • Tilt: 0°
Page 137
Appendices ■ BL-780/781 Unit: mm Bar code type
Narrow bar width
A
CODE39
0.32
480 to 580
435
B
CODE39
0.5
320 to 870
735
C
CODE39
1.0
200 to 1100
930
D
CODE39
2.0
200 to 1200
1010
0
Reading distance
100 200 300 400 500 600 700 800 900 1000 1100 1200
Max. readable label width
Reading distance (mm) 600
500 (Focal length)
500 400 300 200 100 400 465 435 735 930 1010
0 100 200
Appendices
(Measuring conditions) • The KEYENCE standard bar code is used. • Ratio of thin bar to thick bar = 1:2.5 • Skew: 0° • Pitch: 0° • Tilt: 0°
*
300 400 A B C D
500 600
Readable label width (mm)
For the reading distance measuring reference, see P.28.
Note 1: The readable label width means a bar code length including the right and left margins (quiet zones) of a bar code. Note: 2 Even if a bar code is within the above reading range, it may not be read depending on the bar code quality. Set the optimum reading position based on enough reading tests. Note 3: Normally, the reading distance should be set to 500 mm (focal length). In this case, the maximum readable label width is 465 mm (when the narrow bar width is 0.5 mm or more).
124
Page 138
Appendices
Angular Characteristics (Typical) Model BL-700/701
BL-740/741
BL-780/781
Narrow bar width
Skew
Pitch
Tilt
0.15 mm
-70° to -20°, -5° to +55°
±35°
±50°
0.19 mm
-70° to -20°, -5° to +55°
±45°
±50°
0.25 mm
-70° to -20°, -5° to +55°
±50°
±50°
0.5 mm
-70° to -20°, -5° to +55°
±55°
±50°
0.25 mm
-70° to -20°, -5° to +55°
±35°
±30°
0.32 mm
-70° to -20°, -5° to +55°
±45°
±50°
0.5 mm
-70° to -20°, -5° to +55°
±55°
±50°
1.0 mm
-70° to -20°, -5° to +55°
±55°
±30°
0.32 mm
-60° to -20°, -5° to +45°
±20°
±15°
0.5 mm
-70° to -20°, -5° to +50°
±40°
±50°
1.0 mm
-70° to -20°, -5° to +50°
±50°
±50°
Measuring conditions • Bar code: KEYENCE standard bar code • Reading distance: 230 mm (BL-700/701) 380 mm (BL-740/741) 500 mm (BL-780/781) Note: The skew angle of -20° to -5° is the specular reflection range. In this range, bar codes cannot be read, or reading error may occur. Be sure not to mount the BL-700 series at the above skew angles. Skew
Pitch –
0°
+
+
0° –
10°
Appendices
Appendix A.3
Tilt +
0°
Laser beam
–
125
Page 139
Appendices
Appendix B BL-U1 Specifications* Model
BL-U1
Power supply for bar code reader
5 VDC±5% (1.5 A)
Power supply for sensor
12 V ±10% (300 mA)
Trigger input
Input rating
8.5 to 30 VDC, 10 mA max.
OK/NG output
Output type
NPN open-collector
Rated load
30 VDC, 100 mA
Max. OFF current
0.5 mA
Leakage current (at OFF)
0.1 mA max.
Residual voltage (at ON)
1 V max.
Interface
RS-232C, RS-422A, RS-485 multidrop (Up to 31 units can be connected. Max. cable extension: 1.2 km)
Ambient temperature
0 to 50°C (32 to 122°F), No freezing
Relative humidity
35 to 85%, No condensation
Ambient atmosphere Vibration
No dust, no corrosive gas 10 to 55 Hz, 1.5 mm double amplitude in X, Y and Z directions, 2 hours respectively 1000 V p-p, 1 µs (Power line)
Noise immunity Power supply voltage
100 to 240 VAC (50/60 Hz)
Current consumption
40 VA (100 VAC), 50 VA (240 VAC)
Weight
Appendices
Note: This product is not available in Europe.
126
Approx. 615 g (including cable)
Page 140
Appendices
Appendix C BL-U2, N-42 Specifications BL-U2
Connectable bar code reader
N-42
BL-500 series, BL-180 series, BL-700 series
Power supply for bar code reader
5 VDC ±5% (630 mA)
Trigger input
Input rating
15 to 26VDC, 10 mA max.
OK/NG output
Output type
NPN open-collector
Rated load
30 VDC, 100 mA
Maximum OFF current
1.0 mA
Leakage current (at OFF)
0.1 mA max.
Residual voltage (at ON) Interface
Ambient temperature Relative humidity Ambient atmosphere Vibration
1 V max. Conforms to EIA RS-232C.
0 to 50˚C (32 to 122°F), No freezing 35 to 85%, No condensation No dust, no corrosive gas 10 to 55 Hz, 1.5 mm double amplitude in X, Y, and Z directions, 2 hours respectively +10%
Power supply voltage Current consumption Weight
RS-422A (Maximum extension distance: 1.2 km)
24 VDC -20% 250 mA
260 mA max
Approx. 80 g
Approx. 100 g
Appendices
Model
127
Page 141
Appendices
Appendix D Dimensions ■ BL-700/701/740/741/780/781 53 (A) 28.5 ø5.8, Cable length: 1.8 m
Laser beam 10° (*)
Laser transmitter 2 - ø3.5 mounting hole
9.9
58
51.5 26.5 36
3.25
46.5
3.25
* Laser beam emission angle is 10°±0.5° from perpendicular to plane (A).
■ BL-700/701/740/741/780/781 (Mounting bracket) • Vertical scanning • Horizontal scanning
Appendices
58 6
44.5
58 6.5
6
44.5
6.5
16
16
3
3
2.5
60
60
2.5
128
52
2
2.5
52
7
Page 142
Appendices ■ BL-U2
(70) 5.5
2-ø4.5 mounting hole
43.2
5.9 5.9
55
63.2 75
5.5 (70)
21
■ N-42
(70)
Appendices
2 - ø4.5 mounting hole
5.5
43.2 55
5.9 5.9
26 63.2 75
129
Page 143
Appendices ■ BL-U1*
100 to 240 VAC (with 3-core plug)
Approx. 40
ø6.5, Cable length: 2 m
98
90 110
4 - ø5 mounting hole 150 186
Appendices
Note: BL-U1 is not available in Europe.
130
4
4
120°
91 max.
51