Page 104
Chapter 5
Serial Communication
Readout history check Outputs the readout OK and NG counts during trigger input ON.
Command: NUM Response: aaaaa/bbbbb/ccccc aaaaa = 00000 to 65535: Readout OK count bbbbb = 00000 to 65535: Readout NG count ccccc = 00000 to 65535: Trigger input ON count Description: These counts are reset to zero by turning the power OFF or sending the RESET command.
5
91
Page 105
Chapter 5
Serial Communication
5.3.2 Details on Parameter Setting Commands The following describes how to change the BL-700’s settings through command communication. You can use the setup software to change the BL-700’s settings instead of these commands.
Communication Details 1. Send the direct control command SSET to the BL-700. The BL-700 will shift to setting mode. After successfully executing the command, the BL-700 sends back an OK. 2. After the BL-700 shifts to setting mode, send the command (setting change command) corresponding to the item to be changed to the BL-700. After successfully executing the command, the BL-700 sends back an OK. If an error occurs with this command, the BL-700 sends back ERRnn. (nn sttands for error code numbers.) 3. To confirm the current settings, send a setting confirmation command. After successfully executing the command, the BL-700 sends back an OK. If an error occurs with this command, the BL-700 sends back ERRnn. 4. To save the current settings in the EEP-ROM, send SAVE to the BL-700. Once you save the settings in the EEP-ROM, the BL-700 will start with these settings when the BL-700 is turned on next. After successfully executing the command, the BL-700 sends back an OK. If an error occurs with this command, the BL-700 sends back ERRnn.
5
5. To quit the setting mode and perform the normal bar code reading, send SEND to the BL-700. After successfully executing the command, the BL-700 sends back an OK. If an error occurs with this command, the BL-700 sends back ERRnn.
Communication format When the command format is [Command][CR], the response format is [Response][CR]. When the command format is [STX][Command][ETX], the response format is [STX][Response][ETX].
Tips
• • •
Command
Response
Command CR
Response CR
STX Command ETX
STX Response ETX
<LF> can be added at the end of the command being sent. In this case, however, <LF> is not added to the response data. When <ESC> is added before the command being sent, characters in the BL-700’s command receiving buffer are cleared. If the BL-700’s command receiving buffer contains erroneous characters due to a data transmission error during communication, add <ESC> to the command being sent.
Note: For command communication, set the time duration between transmission of each character (byte) to up to 30 seconds. If this duration exceeds 30 seconds, the BL-700 cancels the received characters.
92
Page 106
Chapter 5
Serial Communication
Response Error Code When an incorrect command is sent to set parameters, the BL-700 sends back data indicating the cause of the error (error code). For the commands corresponding to the error codes, see the error code column given in the table on the following pages. Error code
Cause of error
00
Undefined command.
01
Command format is incorrect.
02
Nothing corresponds to the number in the command.
03
“m” value (codes 1 to 4) is other than 0 to 3.
04
“Bar code type setting command” was not sent first. ➮ See P.94.
Sending “No. of readable digits setting command” is invalid for UPC/EAN code. 05
The number in the command is too long.
06
“hhh...” data is too short.
07
“n” value is not 0 or 1.
08
“n” value is exceeding the setting range.
09
“nnn” or “nn” value is exceeding the setting range.
10
“hhh...” is not specified in HEX (hexadecimal) code.
11
“hhh...=FF” cannot be set.
12
“hhh...” or “aaa...” contains more than the specified number of characters.
13
Characters of “aaa...” are invalid.
14
Data in the EEPROM may be damaged. Perform initial setup.
15
Error in the area storing initial settings. Settings are automatically initialized.
17
5
\ is not followed by !, ? or \ in preset data. ➮ See P.137 to 138.
18
Two !s exist in preset data. ➮ See P.100.
99
The BL-700 may malfunction. Contact KEYENCE.
93
Page 107
Chapter 5
Serial Communication
Description of Parameter Setting Commands ■ Saving/Initializing Settings/Quitting Setting Mode Function
Command being sent
Response
Description
Error code
Saves settings in the EEP-ROM.
SAVE
OK
See page 92.
–
Initializes settings.
DFLT
OK
Returns to the default-settings, and saves the settings in the EEP-ROM.
00, 05, 14, 15
Quits the setting mode.
SEND
OK
See page 92.
–
■ Setting Bar Code Type and Number of Readable Digits for Codes 1 to 4 The following describes the parameter setting commands for Codes 1 to 4. Be sure to send “Bar code type setting command” first before setting other parameters. *
When “Bar code type setting command” is newly sent, all other parameters for the specified code will return to the default settings. In this case, set all other parameters again.
Setting change commands and setting confirmation commands are described on the following pages.
5
Function
Command being sent
Setting bar code type for codes 1 to 4.
Change
CODEm=n
Confirm
CODEm
Response
Description
Error code
OK m=0 to 3:Codes 1 to 4
00, 01, mn n=0: CODE 39 1: ITF
03, 05, 08, 14
2: Industrial2of5 3: Codabar 4: UPC/EAN 5: CODE128 6: COOP2of5 7: None 8: CODE93 Setting Max. No. of Change readable digits Confirm
MAXm=nn
OK m=0 to 3: Codes 1 to 4 00, 01,
MAXm mnn nn=01 to 32
03, 04,
* For CODE39,
05, 09,
Codabar: 03 to 32
14
* For ITF: 02 to 32 * For CODE128: 01 to 64
94
Setting Min. No. of readable digits
Change
MINm=nn
OK
Confirm
MINm mnn
CODE39 Sending start/stop character.
Change
WCm00n
OK m=0 to 3: Codes 1 to 4 00, 02,
Confirm
RCm00
00n n=0: Disable
03, 04,
1: Enable
05, 07,
CODE39 Inspection of check digit (Modulus 43)
Change
WCm01n
OK m=0 to 3: Codes 1 to 4 14
Confirm
RCm01
01n n=0: Disable
Note: With EAN code, this command causes error.
1: Enable
Page 108
Chapter 5 Function
Command being sent
CODE39 Sending check digit.
Change
WCm02n
OK m=0 to 3: Codes 1 to 4 00, 02,
Confirm
RCm02
02n n=0: Disable
03, 04,
1: Enable
05, 07,
WCm10n
OK m=0 to 3: Codes 1 to 4 14
WCm10
10n n=0: Disable
ITF Change Inspection of check digit (Modulus 10/ Confirm Wait 3)
Response
Serial Communication
Description
Error code
1: Enable
ITF Sending check digit.
Change
WCm11n
OK m=0 to 3: Codes 1 to 4
Confirm
RCm11
11n n=0: Disable
Codabar Sending start/stop character.
Change
WCm30n
OK m=0 to 3: Codes 1 to 4
Confirm
RCm30
30n n=0: Disable
Codabar Start/Stop character type
Change
WCm31n
OK m=0 to 3: Codes 1 to 4
Confirm
RCm31
31n n=0: Lower case
WCm32n
OK m=0 to 3: Codes 1 to 4
RCm32
32n n=0: Disable
1: Enable
1: Enable
1: Upper case
Change Codabar Inspection of check Confirm digit Change Codabar Sending check digit Confirm
1: Enable WCm33n
OK m=0 to 3: Codes 1 to 4
RCm33
33n n=0: Disable 1: Enable
Codabar Setting check digit type
Change
WCm34n
OK m=0 to 3: Codes 1 to 4 00, 02,
Confirm
RCm34
34n n=0: Mudulus16
03, 04,
1: Modulus 11
05, 08,
2: Modulus 10/Wait 2 14 3: Modulus 10/Wait 3 4: 7 Check DR 5: Modulus 11-A 6: Modulus 10/ Wait 2-A EAN/UPC (A•E) Reading UPC-E EAN/UPC (A•E) Reading EAN 8 digits
Change
WCm40n
OK m=0 to 3: Codes 1 to 4 00, 02,
Confirm
RCm40
40n n=0: Disable
03, 04,
1: Enable
05, 07,
Change
WCm41n
OK m=0 to 3: Codes 1 to 4 14
Confirm
RCm41
41n n=0: Disable 1: Enable
95
5
Page 109
Chapter 5
Serial Communication Function
Command being sent
Response
EAN/UPC(A•E) Reading JAN 13 digits
Change
WCm42n
OK m=0 to 3: Codes 1 to 4 00, 02,
Confirm
RCm42
42n n=0: Disable
03, 04,
1: Enable
05, 07,
EAN/UPC(A•E) No. of UPC-A output digits
Change
WCm43n
OK m=0 to 3: Codes 1 to 4 14
Confirm
RCm43
43n n=0:Output in 13 digits
EAN/UPC(A•E) Adding “0” to UPCE system code
Change
WCm44n
OK m=0 to 3: Codes 1 to 4
Confirm
RCm44
44n n=0: Disable 1: Enable
WCm51n
OK m=0 to 3: Codes 1 to 4
RCm51
51n n=0: Disable 1: Enable
➮ See p. 32.
Change
WCm83n
OK m=0 to 3: Codes 1 to 4
Confirm
RCm83
83n n=0: Disable 1: Enable
Setting direction for Change max. code length Confirm output
WCm84n
OK m=0 to 3: Codes 1 to 4
RCm84
84n n=0: Forward
WCm85nn
OK m=0 to 3: Codes 1 to 4 00, 02,
RCm85
85nn nn=01 to 32
WCm86nn
OK m=0 to 3: Codes 1 to 4 14
RCm86
86nn nn=01 to 32
Setting label orientation specified reading
Change
WCm81n
OK m=0 to 3: Codes 1 to 4 00, 02,
Confirm
RCm81
81n n=0: Disable
03, 04,
1: Enable
05, 07,
Setting orientation for orientationspecified reading
Change
WCm82n
OK m=0 to 3: Codes 1 to 4 14
Confirm
RCm82
82n n=0: Forward
Change Setting effective digits for max. code Confirm length output
5
Setting starting digit Change for max. code Confirm length output
96
Error code
1:Output in 12 digits
CODE128 Checking Change double character Confirm start pattern
Setting max. code length output function
Description
1: Reverse
: Effective digits
03, 04, 05, 09,
: Starting digit
1: Reverse
Page 110
Chapter 5
Serial Communication
■ Setting Reading Mode/Data Addition Functions Function
Command being sent
Response
Description
Error code
Setting reading mode
Change
WP12n
OK n=0: Single label
00, 02,
Confirm
RP12
12n
1: Multi label 1
05, 08,
2: Multi label 2
14
3: Multi label 3 Setting data send timing
Change
WP13n
OK
Confirm
RP13
13n
N=0: Sends data after 00, 02, reading
05, 07,
1: Sends after timing 14 input turns off Setting repeat-read Change time in multi label Confirm reading mode 1 or 2
OK nnn=001 to 225
00, 02,
41nnn
(by 100 ms step)
05, 09, nnn=001 to 225
14
Setting decoding match count
Change
WP43nnn
OK
Confirm
RP43
43nnn
Setting decoding match count in additional information
Change
WP10n
OK
Confirm
RP10
10n
Setting scans in additional information
Change
WP11n
OK
Confirm
RP11
11n
1: Add
00, 02, 05, 07, n=0: No addition 1: Add
5
Note: Effective only when No. of decodings are added.
Setting code type in Change additional information Confirm Setting reading error code n=0: No addition
14
Change Setting label orientation in Confirm additional information
Tips
WP41nnn RP41
WP14n
OK
RP14
14n n=0: No addition 1: Add
WP17n
OK
RP17
17n n=0: No addition
Change
WP55hhh...
OK hhh ... = Reading error
Confirm
RP55
55hhh...
code (within 8 characters) 05, 06, * Specify the charac- 10, 12, ters in HEX (hexadeci- 14 mal) code. * If the reading error code is not specified, hhh... = FF.
1: Add 00, 02,
To set the reading error code, send the following command: Example 1 Set the reading error code to “BR”. BR WP554252 * B = 42h, R = 52h Example 2 Set no reading error code. WP55FF
97
Page 111
Chapter 5
Serial Communication ■ Setting Trigger Input (Starting Test Mode)
5
Function
Command being sent
Response
Description
Setting signal type
Change
WP05n
OK n=0: Level
Confirm
RP05
05n
1: One-shot
Setting one-shot input time
Change
WP42nnn
OK nnn=001 to 225
Confirm
RP42
42nnn
Setting time constant of trigger input
Change
WP04n
OK n=0: 2 ms
Error code 00, 02, 05, 07, 14 00, 02, 05, 09, 14 00, 02,
Confirm
RP04
04n
1: 10 ms
05, 07,
Setting state of trigger input
Change
WP03n
OK
Confirm
RP03
03n
Starting test mode when trigger input turns on. (To specify the test mode, use the command below.)
Change
WP06n
OK n=0: Disable
Confirm
RP06
06n
1: Enable
Specifying the test mode to be started when trigger input turns on.
Change
TRGTn
OK
Confirm
TRGT
TRGTn
Starting test mode when power is turned on.
Change
TESTn
OK
Confirm
TEST
TESTn
(by 100 ms step)
14 n=0: Normal-open 1: Normal-close
N=1: Reading rate
00, 02, check mode
05, 08,
2: Tact check mode 14 n=0: Reset 1: Reading rate check mode 2: Tact check mode
Setting characters of trigger on command
Change
WP56hhh...
OK hhh...=Trigger on
00, 02,
Confirm
RP56
56hhh...
command (Up to 8
05, 11, characters)
14
* Specify characters in HEX (hexadecimal) code. Setting characters of trigger off command
Change
WP57hhh...
OK
Confirm
RP57
57hhh...
hhh...=Trigger off command (Up to 8 characters) * Specify characters in HEX (hexadecimal) code.
Tips
To set characters of the trigger on/Off command, send the following command. Example 1 Change the trigger on command to S. S WP5653 * S=53h
98
Page 112
Chapter 5
Serial Communication
■ Setting Communication Parameters 1 Function
Command being sent
Response
Description
Error code
Setting baud rate
Change
WP35n
OK
N=5: 38400 bps
00, 02,
Confirm
RP35
035n
6: 31250 bps
05, 08,
7: 19200 bps
14
0: 9600 bps 1: 4800 bps 2: 2400 bps 3: 1200 bps 4: 600 bps Setting data bit length
Change
WP30n
OK
Confirm
RP30 WP31n RP31
Setting parity check Change * To set the parity Confirm type, use the command below. Setting parity type Setting Stop bit n=0: 7 bits
00, 02,
30n
1: 8 bits
05, 07,
OK n=0: Disable
31n
1: Enable
Change
WP32n
OK n=0: Even
Confirm
RP32
32n
1: Odd n=0:1 bit
Change
WP33n
OK
Confirm
RP33
33n
1: 2 bits
Setting RTS/CTS handshaking
Change
WP22n
OK n=0: Disable
Confirm
RP22
22n
1: Enable
Setting RS-485 multi drop link
Change
WP34n
OK n=0: Disable
Confirm
RP34
34n
1: Enable
Setting ID No. for RS-485 multi drop link.
Change
WP44nn
OK nn=01 to 31
Confirm
RP44
44nn
14
5 00, 02, 05, 09, 14
99
Page 113
Chapter 5
Serial Communication ■ Setting communication parameters 2 (When the PLC link is not used) Function
Command
Response Description
Error code
Handshaking protocol 1
Change
OK n = 0: No handshaking n = 1: Use protocol
00, 02,
*To set details of the protocol, use handshaking protocol 2.
14
Handshaking protocol 2
Adding checksum
Header
Delimiter
WP07n
Confirm RP07
07n
Change
WP08n
OK n = 0: PASS/RTRY protocol
Confirm
RP08
08n n = 1: ACK/NAK protocol
Change
WP39n
OK n = 0: Do not add
Confirm
RP39
39n
Change
WP51hhh... OK n = 1: Add
51hhh...
Confirm
RP51
Change
WP52hhh... OK
Confirm
RP52
5
Tips
52hhh...
hhh... = Header (up to five characters) * To set a header, use HEX (hexadecimal) codes. * hhh... = FF: Header is not set. hhh... = Delimiter (up to five characters) * To set a delimiter, use HEX (hexadecimal) codes. * hhh... = FF: Delimiter is not set.
To set the header and delimiter, send the following command: Example Set the communication data format to <SOH> 01 bar code data A <CR>. SOH 0
1
WP51013031
A CR
WP52410D
* SOH =01h, 0=30h, 1=31h, A=41h, CR =0Dh
100
05, 07,
00, 02, 05, 06, 10, 12, 14