BL-600 Series User's Manual: Laser Bar Code Reader, pages 51 to 60
Pages 51 to 60 of 112
The original document is the PDF (1.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Keyence BL-600 and Keyence BL-601
Page 51
Chapter 7 Function
Command being sent
CODE39 Sending check digit.
Change
WCm02n
OK m=0 to 3: Codes 1 to 4 00, 02,
Confirm
RCm02
02n n=0: Disable
03, 04,
1: Enable
05, 07,
WCm10n
OK m=0 to 3: Codes 1 to 4 14
WCm10
10n n=0: Disable
ITF Change Inspection of check digit (Modulus 10/ Confirm Wait 3)
Response
Serial Communication
Description
Error code
1: Enable
ITF Sending check digit.
Change
WCm11n
OK m=0 to 3: Codes 1 to 4
Confirm
RCm11
11n n=0: Disable
Codabar Sending start/stop character.
Change
WCm30n
OK m=0 to 3: Codes 1 to 4
Confirm
RCm30
30n n=0: Disable
Codabar Start/Stop character type
Change
WCm31n
OK m=0 to 3: Codes 1 to 4
Confirm
RCm31
31n n=0: Lower case
WCm32n
OK m=0 to 3: Codes 1 to 4
RCm32
32n n=0: Disable
1: Enable
1: Enable
1: Upper case
Change Codabar Inspection of check Confirm digit Change Codabar Sending check digit Confirm
1: Enable WCm33n
OK m=0 to 3: Codes 1 to 4
RCm33
33n n=0: Disable 1: Enable
Codabar Setting check digit type
Change
WCm34n
OK m=0 to 3: Codes 1 to 4 00, 02
Confirm
RCm34
34n n=0: Modulus16
03, 04,
1: Modulus 11
05, 08,
2: Modulus 10/Wait 2 14 3: Modulus 10/Wait 3 4: 7 Check DR 5: Modulus 11-A 6: Modulus 10/
7
Wait 2-A EAN/UPC (A•E) Reading UPC-E EAN/UPC (A•E) Reading EAN 8 digits
Change
WCm40n
OK m=0 to 3: Codes 1 to 4 00, 02,
Confirm
RCm40
40n n=0: Disable
03, 04,
1: Enable
05, 07,
Change
WCm41n
OK m=0 to 3: Codes 1 to 4 14
Confirm
RCm41
41n n=0: Disable 1: Enable
121
Page 52
Chapter 7
Serial Communication Function
Command being sent
EAN/UPC (A•E) Reading JAN 13 digits
Change
WCm42n
OK m=0 to 3: Codes 1 to 4 00, 02,
Confirm
RCm42
42n n=0: Disable
03, 04,
1: Enable
05, 07,
EAN/UPC (A•E) No. of UPC-A output digits
Change
WCm43n
OK m=0 to 3: Codes 1 to 4 14
Confirm
RCm43
43n n=0:Output in 13 digits
➮ See p. 32.
Setting max. code length output function
OK m=0 to 3: Codes 1 to 4
44n n=0: Disable
Error code
1: Enable WCm51n
OK m=0 to 3: Codes 1 to 4
Confirm
RCm51
51n n=0: Disable 1: Enable
Change
WCm83n
OK m=0 to 3: Codes 1 to 4
Confirm
RCm83
83n n=0: Disable 1: Enable
WCm84n
OK m=0 to 3: Codes 1 to 4
RCm84
84n n=0: Forward
WCm85nn
OK m=0 to 3: Codes 1 to 4 00, 02,
RCm85
85nn nn=01 to 32
WCm86nn
OK m=0 to 3: Codes 1 to 4 14
RCm86
86nn nn=01 to 32
Setting label orientation specified reading
Change
WCm81n
OK m=0 to 3: Codes 1 to 4 00, 02,
Confirm
RCm81
81n n=0: Disable
03, 04,
1: Enable
05, 07,
Setting orientation for orientationspecified reading
Change
WCm82n
OK m=0 to 3: Codes 1 to 4 14
Confirm
RCm82
82n n=0: Forward
Change Setting effective digits for max. code Confirm length output Setting starting digit Change for max. code Confirm length output
122
WCm44n RCm44
Change
Setting direction for Change max. code length Confirm output
7
Description
1:Output in 12 digits
Change EAN/UPC (A•E) Adding “0” to UPC- Confirm E system code CODE128 EAN-128 support
Response
1: Reverse
: Effective digits
03, 04, 05, 09,
: Starting digit
1: Reverse
Page 53
Chapter 7
Serial Communication
■ Setting Reading Mode/Data Addition Functions Function
Command being sent
Response
Description
Error code
Setting reading mode
Change
WP12n
OK n=0: Single label
00, 02,
Confirm
RP12
12n
1: Multi label 1
05, 07,
2: Multi label 2
14
3: Multi label 3 Setting data send timing
Change
WP13n
OK
Confirm
RP13
13n
N=0: Sends data after 00, 02, reading
05, 07,
1: Sends after timing 14 input turns off Setting repeat-read Change time in multi label Confirm reading mode 1 or 2
WP41nnn
OK nnn=001 to 225
00, 02,
RP41
41nnn
(by 100 ms step)
05, 09, nnn=001 to 225
14
Setting decoding match count
Change
WP43nnn
OK
Confirm
RP43
43nnn
Setting decoding match count in additional information
Change
WP10n
OK
Confirm
RP10
10n
Setting scans in additional information
Change
WP11n
OK
Confirm
RP11
11n n=0: No addition 1: Add
00, 02, 05, 07, 14 n=0: No addition 1: Add Note: Effective only when No. of decodings are added.
Change Setting label orientation in Confirm additional information Setting code type in Change additional information Confirm
WP14n
OK
RP14
14n
WP17n
OK
RP17
17n
Adding a symbol identifier
Change
WP80n
OK
Confirm
RP80
80n
Adding PMI (Preventive maintenance information)
Change
WP86n
OK
Confirm
RP86
86n
PMI Preset value 1 (L1)
Change
WP48nnn
OK
Confirm
RP48
48nnn
PMI Preset value 2 (L2)
Change
WP49nnn
OK
Confirm
RP49
49nnn
Setting reading error code
Change
WP55hhh...
Confirm
RP55 n=0: No addition 1: Add
7 n=0: No addition 1: Add n=0: No addition 1: Add n=0: No addition 1: Add nnn= 000 to 100
00, 02, 05, 07, nnn= 000 to 100
14
OK hhh ... = Reading error
00, 02,
55hhh...
code (within 8 characters) 05, 06, * Specify the charac- 10, 12, ters in HEX (hexadeci- 14 mal) code. * If the reading error code is not specified, hhh... = FF.
123
Page 54
Chapter 7
Serial Communication Tips
To set the reading error code, send the following command: Example 1 Set the reading error code to “BR”. BR WP554252 * B = 42h, R = 52h Example 2 Set no reading error code. WP55FF ■ Setting trigger input (Starting test mode)
7
Function
Command being sent
Response
Description
Setting signal type
Change
WP05n
OK n=0: Level
Confirm
RP05
05n
1: One-shot
Setting one-shot input time
Change
WP42nnn
OK nnn=001 to 225
Confirm
RP42
42nnn
Setting time constant of trigger input
Change
WP04n
OK n=0: 2 ms
00, 02,
Confirm
RP04
04n
1: 10 ms
05, 07,
Setting state of trigger input
Change
WP03n
OK
Confirm
RP03
03n
Trigger the input status at power-on
Change
WP02n
OK
Confirm
RP02
02n
1: ON
Starting test mode when trigger input turns on. (To specify the test mode, use the command below.)
Change
WP06n
OK n=0: Disable
Confirm
RP06
06n
1: Enable
Specifying the test mode to be started when trigger input turns on.
Change
TRGTn
OK
Confirm
TRGT
TRGTn
Starting test mode when power is turned on.
Change
TESTn
OK
Confirm
TEST
TESTn
Setting characters of trigger on command
Change
WP56hhh...
OK hhh...=Trigger on
00, 02,
Confirm
RP56
56hhh...
command (Up to 8
05, 11, characters)
14
(by 100 ms step)
Error code 00, 02, 05, 07, 14 00, 02, 05, 09, 14
14 n=0: Normal-open 1: Normal-close n=0: OFF n=1: Reading rate
00, 02, check mode
05, 08,
2: Tact check mode 14 n=0: Reset 1: Reading rate check mode 2: Tact check mode
* Specify characters in HEX (hexadecimal) code. Setting characters of trigger off command
Change
WP57hhh...
OK hhh...=Trigger off
Confirm
RP57
57hhh...
command (Up to 8 characters) * Specify characters in HEX (hexadecimal) code.
124
Page 55
Chapter 7 Tips
Serial Communication
To set characters of the trigger On/Off command, send the following command. Example 1 Change the trigger on command to S. S WP5653 * S=53h
■ Setting communication parameters 1 Function
Command being sent
Response
Description
Error code
Setting baud rate
Change
WP35n
OK n=5: 38400 bps
00, 02,
Confirm
RP35
035n
6: 31250 bps
05, 08,
7: 19200 bps
14
0: 9600 bps 1: 4800 bps 2: 2400 bps 3: 1200 bps 4: 600 bps Setting data bit length
Change
WP30n
OK
Confirm
RP30 WP31n RP31
Setting parity check Change * To set the parity Confirm type, use the command below. Setting parity type Setting Stop bit n=0: 7 bits
00, 02,
30n
1: 8 bits
05, 07,
OK n=0: Disable
31n
1: Enable
Change
WP32n
OK
Confirm
RP32
32n
1: Odd
Change
WP33n
OK n=0:1 bit
14 n=0: Even
Confirm
RP33
33n
1: 2 bits
Setting RTS/CTS handshaking
Change
WP22n
OK n=0: Disable
Confirm
RP22
22n
1: Enable
Setting RS-485 multi drop link
Change
WP34n
OK n=0: Disable
Confirm
RP34
34n
1: Enable
Setting ID No. for RS-485 multi drop link.
Change
WP44nn
OK nn=01 to 31
Confirm
RP44
44nn
7
00, 02 05, 09, 14
125
Page 56
Chapter 7
Serial Communication ■ Setting communication parameters 2 (When the PLC link is not used) Function
Command
Response
Description
Error code
Handshaking protocol 1
Change
OK n = 0: No handshaking n = 1: Use protocol
00, 02,
*To set details of the protocol, use handshaking protocol 2.
14
Handshaking protocol 2
Adding checksum
WP07n
Confirm RP07
07n
Change
WP08n
OK n = 0: PASS/RTRY protocol
Confirm
RP08
08n n = 1: ACK/NAK protocol
Change
WP39n
OK n = 0: Do not add
Confirm
RP39
39n
Change
WP51hhh... OK n = 1: Add
Header
Delimiter
Transmission delay time
51hhh...
Confirm
RP51
Change
WP52hhh... OK
Confirm
RP52
52hhh...
Change
WP98nnn
OK
Confirm
RP98
98nnn hhh... = Header (up to five characters) * To set a header, use HEX (hexadecimal) codes. * hhh... = FF: Header is not set. hhh... = Delimiter (up to five characters) * To set a delimiter, use HEX (hexadecimal) codes. * hhh... = FF: Delimiter is not set.
00, 02, nnn = 000 to 255 (by 10 ms step)
00, 02, 05, 09, 14
7 Tips
To set the header and delimiter, send the following command: Example Set the communication data format to <SOH> 01 bar code data A <CR>. SOH 0
1
A CR
WP51013031
WP52410D
* SOH =01h, 0=30h, 1=31h, A=41h, CR =0Dh
126
05, 07,
05, 06, 10, 12, 14
Page 57
Chapter 7
Serial Communication
■ Setting communication parameters 2 (only when PLC link is used) Function
Command
PLC link model
Change
Response Description WP36n
OK n = 0: PLC link disabled n = 1: SYSNAC-C n = 2: MELSEC-A
Confirm
RP36
36n
Error code 00, 02, 05, 07, 14 n = 3: KV n = 4: MELSEC-A (File register is used.)
Trigger input through PLC link
Change
WP37n
OK
Confirm
RP37
37n
DM head address
Change
WP45nn
OK
Confirm
RP45
45nn
Change
WP47nn
OK
Confirm
RP47
47nn
Change
WP46nnn
OK
Confirm
RP46
46nnn
PLC / station number
File register block number n = 0: Disable n = 1: Enable nn = 00 to 99 (0000 to 9900)
00, 02, 05, 09, 14 nn = 00 to 31 nnn = 000 to 255
■ Setting communication strings Function
Setting interme- Change diate delimiter when multi label reading mode 2 Confirm or 3 is used.
Response Description
Command
Setting partition Change mark when additional Confirm information is used.
WP50hh
OK
RP50
50hh
WP54hhh... OK RP54
54hhh...
hh = Partition mark (1 character) * Specify the mark in HEX (hexadecimal) code.
Error code 00, 02, 05, 06, 10, 12, 14
7 hhh = Intermediate delimiter (Up to 5 characters) * Specify the mark in HEX (hexadecimal) code. * To set no intermediate delimiter, hhh = FF.
127
Page 58
Chapter 7
Serial Communication ■ Utility Setting (Stability LED, OK/NG output duration, Preset data for compare) Function
Command being sent
Response
Description
Error code
Indication of Stability LED
Change
WP09n
OK n=0: Disable
Confirm
RP09
09n
1: Enable
00, 02, 05, 07, 14
Change
WP40nnn
OK nnn= 001 to 255
Confirm
RP40
40nnn
(by 10 ms step)
Setting OK/NG output duration
7 Tips
Registration of preset data for compare
Change
WP68aaa...
OK aaa...= Preset data
Confirm
RP68
68aaa...
(Up to 32 characters)
Scaling factor for the quiet zone
Change
WP0Mn
OK
Confirm
RP0M
0Mn
Reading a reversed bar code
Change
WP0Rn
OK n= 0: OFF
Confirm
RP0R
0Rn
1: On
Outputting the test mode result
Change
WP85n
OK
Confirm
RP85 n
Changing the decoding match count
Change
WP93nnn
OK
Confirm
RP93
93nnn
* For CODE128, see P.136 to 137. * To delete the preset data, send WP68.
To register the preset data, send the following command. Example Register “ABC123” as preset data. WP68ABC123
128 n = 0: 4x 1: 5x 2: 6x 3: 7x 4: 8x 5: 9x 6: 10x 7: 11x n = 0: Disable output 1: Enable output nnn= 000 to 255
00, 02, 05, 09, 14 00, 02, 05, 12, 13, 14, 17, 18
00, 02, 05, 07, 14
Page 59
Chapter 8 PLC Link This chapter describes the PLC link control.
8.1
PLC Link ............................................................................. 130
8.1.1 List of PLCs used for PLC link ............................................. 130 8.1.2 Devices used for PLC link .................................................... 131 8.2
Setting the BL-600 and PLC .............................................. 132
8.2.1 Setting the BL-600 Series .................................................... 132 8.2.2 Setting the PLC .................................................................... 132 8.3
Device Assignment ............................................................ 135
8.3.1 Data memory head address ................................................ 135 8.3.2 Data memory areas ............................................................. 136 8.3.3 Detailed description of device assignment .......................... 137 8.4
PLC Link Error ................................................................... 142
8.5
Communication Time ........................................................ 143
Page 60
Chapter 8
8.1
PLC Link
PLC Link This section describes the applicable PLCs and devices for the PLC link. Since the BL-600 directly controls the PLC’s memory, no program is required for data communication, resulting in a reduced number of programming steps. As compared with the serial communication using a computer, the PLC link involves the following limitations: •
The BL-600 settings cannot be changed because the PLC link cannot send a command to the BL-600. However, the PLC link provides a reading control address to start/end reading.
•
The PLC link cannot start the test mode.
8.1.1 List of PLCs used for PLC link KEYENCE KV Series
Built-in CPU port Serial interface module Built-in CPU port
Mitsubishi MELSEC-A Series
Calculator link unit
Built-in CPU port OMRON SYSMAC-C Series High-order link unit Communication board OMRON SYSMAC-CQM1 Series
8
OMRON SYSMAC-CV Series
KV-10/16/24/40/80, KV-300 NEW KV-10/16/24/40 KV-L2 A2CCPUC24, A2CCPUC24-PRF AJ71(U)C24(-Sx), AJ71Q24(-R2/R4), A0J2-C214-S1 A1SJ71(U)C24-R2/PRF/R4 C20H/28H/40H C200HS-CPU21/23/31/33 C200HE-CPU/32/42 C200HG-CPU33/43/53/63 C200HX-CPU34/44/54/64 C200HX-CPU65-Z/85-Z C200H-LK201(-V1), C500-LK203 C500-LK201-V1, C120-LK201-V1 C200H-LK202(-V1), C120-LK202-V1 C200HW-COM02/COM03/COM04/ COM05/COM06
Built-in CPU port
CQM1-CPU21/41/42/43/44
Built-in CPU port
CV500/1000, CV-M1
High-order link unit
CV500-LK201
Note: KV-300 and KV-L2 are not available in Europe.
130