The text of a manual · part 3 of 14
BL-180 Series User's Manual, CCD Bar Code Reader: Chapter 1 Connection and Installation
Pages 9 to 16 of 109, from BL-180 Series User's Manual, CCD Bar Code Reader
The original document is the PDF (568 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Keyence BL-180 and Keyence BL-185
Page 9
Chapter 1 Connection and Installation
Page 10
1.1 BL-180 Connections
1.1 BL-180 Connections 1.1.1 Wire colors and signal types The following wires extend from the BL-180. Solder the required wires to a connector to connect the BL-180 to a computer/controller. Wire Color
Symbol
Shield Purple Brown Pink Blue
Shield RS232C
Black
GND (SG)
Yellow White Gray Red
TIM OK NG + 5V
Description
SD (TXD) RD (RXD) RS (RTS) CS (CTS)
Signal Direction
Connect to ground (SG) Send data Receive data Request to send (always on) Request to receive Ground (common ground for respective signals) Trigger input OK output NG output + 5V power supply input, - Output Input Output Input, - Input Output Output Input
1.1.2 Power supply wiring BL-180
CAUTION
+5V
Red
GND
Black
+
5VDC
• Be sure to match the polarities of the power supply when soldering the connections. Reversing the polarities will damage the unit. • Make sure that the power supply provides a stable 5 VDC ± 5%. If the power supply does not function in the above range, it can damage the unit. • Do not use a power cable longer that 2 meters. A long power cable can cause a voltage drop, preventing the BL-180 from starting properly. • If the power supply is UL rated, it must provide Class 2 output.
1.1.3 Wiring I/O Trigger (TIM) input The trigger input is used to signal the BL-180 to start reading (Start laser emission). The trigger input is a non-voltage input (TTL input is also available).
Internal circuit
BL-180
2
10KΩ
5VDC
4.7 KΩ
TIM
Yellow
GND
Black
With or without relay
Page 11
1.1 BL-180 Connections OK/NG output This output signals whether the readout data is the same as the preset data. When no preset data has been registered, the signal indicates bar code read status. It is an NPN open-collector output.
Internal circuit
BL-180
OK/NG Write/Gray
1kΩ
GND
Black
Load
+
*Rated load: 24 VDC (100 mA) max.
1.1.4 RS-232C Connections Note
This BL-180 setup software applies to port 1 and port 2 only. Communication cannot be performed with another port. When using a D-sub 9-pin connector: BL-180 Shield SD RD CS RS GND +5V
Shield
Purple Blown Blue Pink Black Red + 5VDC
PC – Connector case 2 RD 3 SD 7 RS 8 CS 5 SG 4 DR 6 ER D-sub 9-pin (male) # 4-40 screw
Use a metallic connector housing for the D-sub 9-pin connector. Connect the shielded cable with the connector housing. When using a D-sub 25-pin connector: BL-180 Shield Shield RD Blown SD Purple CS Blue RS Pink GND Black +5V Red + 5VDC
Note
PC 1 FG 2 SD 3 RD 4 RS 5 CS 7 SG 6 DR 20 ER D-sub 25-pin (male) M 2..6 screw
Be sure the BL-180’s shielded cable is properly connected. Refer to “1.1.3 Connecting shielded cables” in the User’s Manual.
3
Page 12
1.1 BL-180 Connections Hints on correct use Trigger (TIM) input Set the trigger input to be long enough to allow the laser beam to cover the entire bar code. If the trigger input needs to be on for only a short period of time, select one-shot mode. Influence from mirror surface If a mirror surface (metallic surface) is near the bar code and the laser beam reflects off the mirror, the BL-180 may cause a read error. Protect the unit from the influence of a mirror surface by covering the surface or changing the bar code label position. Bar code pitch Do not place several bar codes in the field of the laser beam, unless you are in multi-label read mode (Multi 3).
BL-180
OK/NG STABILITY
If you use multi-label read mode (multi 3), the BL-180 can simultaneously read 2 to 4 bar codes in the field of the laser beam. Influence from photoelectric sensor When using a photoelectric sensor to control trigger, block the sensor beam so it does not enter the BL-180 optical pickup. The beam from the photoelectric sensor can interfere with the BL-180, deteriorating reading performance. If this case, reposition the photoelectric sensor. Object
Bar code
BL-180
OK/NG STABILITY
Light source Optical pickup
4
Page 13
1.1 BL-180 Connections Bar code height The bar code height must be at least 3 mm. However, adjust any bar code of 3 mm or more height so that it is arranged from one end to the other on the lightreceiving axis. 3 mm or more
Lightreceiving axis
5
Page 14
1.2 Installing the BL-180 Series
1.2 Installing the BL-180 Series Installation method Use the mounting holes on the side panel to install the unit. To prevent dust from entering the unit, seals have been placed over the screw holes. Remove the seals before mounting. Using the supplied mounting brackets Install the BL-180 Series as shown in the figures below. BL-180 pattern 1
BL-180 pattern 2
M3 screws
M3 screws
(BL-185)
M3 screws
• Select screws of the proper length by checking the thickness of the plate used for mounting. (The screws provided are for use with the mounting bracket.) • For the mounting hole diameter, see page 65. Installation with no mounting bracket (BL-180)
(BL-185)
• Prepare M3 male screws separately. • Although the mounting holes are on both sides of the unit, only one side should be mounted. • For the mounting hole diameter, see page 65.
CAUTION
Do not insert screws into the BL-180 by 5 mm or deeper. Doing so may damage the unit parts. Select screws of the proper length by checking the thickness of the plate used for mounting.
6
Page 15
1.2 Installing the BL-180 Series Mounting angle and mounting distance 12.5
BL-180
15.3
BL-180
10° 33
Light-receiving axis
BL-185
Set the angle and reading distance by referring to the read range characteristics and angle characteristics described on page 63 and 64. The allowable reading distance and angle may vary depending on the narrow bar width of the bar code, the bar code size, and the readability of the bar code. Set these parameters after performing a test read of the required bar code using the unit.
Note
Do not set the unit at an angle at which the light-receiving axis is perpendicular to the surface of the bar code. The beam will be fully reflected into the reader, making correct reading impossible (see page 64). Set the angle so that the light-receiving axis will be centered on the bar codes. Bar codes of insufficient height may deviate from the desired position in relation to the light-receiving axis. Be sure to position the unit carefully. (The bar codes must have a height of at least 3 mm.) The reading check test mode (see page 17) allows you to set the optimal reading position.
7
Page 16
1.2 Installing the BL-180 Series
8