BL-180 Series User's Manual, CCD Bar Code Reader: BL-U1 Power Supply, pages 103 to 109

Pages 103 to 109 of 109, from BL-180 Series User's Manual, CCD Bar Code Reader

The original document is the PDF (568 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Keyence BL-180 and Keyence BL-185

Page 103

Power Supply BL-U1 5.4 Details of Command Communication All RS-232C and RS-422A serial communication commands can be used.

Communication Procedure

ID•••1 1 S TX

010

02

LON

7E

E

2 S TX

010

02

LON

7E

E

4 S TX

009

02

OK

3F

E

T X

ID•••2 T X

3Timing input turns ON.

T X

ID•••3

ID•••4

1. Send a command from the host computer to the BL series you wish to operate. [STX] mmm nn

Command cc

[ETX]

2. Data, including the same command, loops back to the host computer. [STX] mmm nn

Command cc

[ETX]

3. The specified BL series receives the command and performs the required operation. 4. The BL series sends back the following data in response to the command. [STX] mmm nn

Response cc

[ETX]

Response to the direct control command or the setting change command: OK Response to the setting confirmation command: Current settings If an error occurs with the specified command, the BL series sends back the following response. [STX] mmm nn

ERR** cc

[ETX]

** indicates an error code (see p. 70).

If incorrect characters are specified for the data communication commands (P, C), the BL series sends back ERR**.

97

Page 104

Power Supply BL-U1 Example:

When the command to shift to the setting mode (SSET) is sent to the BL series of ID No. 3:

1. From the host computer: [STX]

011

03

SSET

22

[ETX]

011

03

SSET

22

[ETX]

009

03

OK

3E

[ETX]

2. Loopback data: [STX]

3. From the BL series: [STX]

CAUTION

If an incorrect ID number is specified, an incorrect format is used to send a command, or a data transmission error occurs (checksum is incorrect), the BL series sends back no response. You will need to design a program so that the same command is sent again (Retry) if the BL series sends back no response within a specified period (Timeout). With RS-232C or RS-422A communication, the BL series sends back no data in response to some of the direct control commands (e.g. LOG<CR>). With the multidrop link, however, the BL series sends back the following data in response to those commands. During normal processing: OK When error occurs: ERR** ** indicates an error code (see p. 70).

98

Page 105

Power Supply BL-U1

6

Precautions for Programming • Since the multidrop link requires communication of many commands, the host computer must have high processing ability. As the number of connected BL series increases, the host computer needs higher data processing speed. When the host computer’s processing speed is insufficient, the BL series’ transmission buffer will become full, and the BL series will send back the following response. [STX]

011

03

OVER

22

[ETX]

The BL series clears all data stored in the transmission buffer. To prevent this, replace the host computer with a higher performance unit (including processing of the programming language), or reduce the number of the BL series connected to the host computer. • If an incorrect ID number is specified, an incorrect format is used to send a command, or a data transmission error occurs (checksum is incorrect), the BL series sends back no response. You will need to design a program so that the same command is sent again (Retry) if the BL series sends back no response within a specified period (Timeout).

99

Page 106

Power Supply BL-U1

BL-U1 Specifications Model

BL-U1

Power supply for bar code reader

5 VDC±5% (1.5 A)

Power supply for sensor

12 V ±10% (300 mA)

OK/NG output Trigger input

7

Input rating

8.5 to 30 VDC, 10 mA max.

Max. OFF current

1.0 mA

Output type

NPN open-collector

Rated load

30 VDC, 100 mA

Leakage current (at OFF)

0.1 mA max.

Residual voltage (at ON)

Environment

Interface Ambient temperature

0 to 50°C

Relative humidity

35 to 85%

Ambient atmosphere

No dust, no corrosive gas

Vibration

10 to 55 Hz, 1.5 mm double amplitude in X, Y and Z directions, two hours respectively

Noise immunity Insulation resistance

Rating

Insulation withstand voltage

1000 V p-p, 1 µs (Power line) At least 100 MΩ across earth ground and AC power supply terminals (by 500 VDC Megger) 1500 VAC across earth ground and AC power supply terminals, for 1 minute

Power supply voltage

100 to 240 VAC (50/60 Hz)

Current consumption

40 VA (100 VAC), 50 VA (240 VAC)

Weight

100

1 V max. RS-232C, RS-422A, RS-485 multidrop (Up to 31 units can be connected. Max. cable extension: 1.2 km)

Approx. 615 g (including cable)

Page 107

Power Supply BL-U1 BL-U1

Approx. 40

100 to 240 VAC (with 3-core plug)

90

98 110

ø6.5, Cable length: 2 m

4 x ø5 mounting hole 150 186

4

4

120°

91 max.

51

101

Page 108

Power Supply BL-U1 When using the BL-U1

For a PC with a 9-pin D-sub RS-232C connector If the RS-232C interface of your personal computer uses a D-sub 9-pin connector, prepare a cable as described below. BL-U1 FG 1 SD 2 RD 3 RS 4 CS 5 SG 7 DR 6 ER 20 D-sub 25-pin (male) M 2.6 screw

PC – Connector case 2 RD 3 SD 4 ER 6 DR 5 SG 7 RS 8 CS D-sub 9-pin (female) #4-40 screw

Be sure to use a metal connector case for the 9-pin D-sub connector. Connect the connector case to the shield wire.

The BL-U1 can also be connected to a personal computer using a 25-pin to 9-pin adapter and a 25-pin to 25-pin null modem cable as described below. The optional OP-22149 null modem cable (1.5 m) is available from KEYENCE. 25-pin to 25-pin null modem cable OP-22149 (1.5 m)

BL-U1

102

25- to 9-pin adapter OP-25057

IBM-PC/AT compatible

Page 109

A58-001

User’s Manual CCD Bar Code Reader

BL-180 Series

Worldwide Headquarters KEYENCE CORPORATION 1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku, Osaka, 533-8555, Japan PHONE: 81-6-6379-2211 FAX: 81-6-6379-2131

KEYENCE CORPORATION OF AMERICA PHONE: 201-930-0100 FAX: 201-930-0099

KEYENCE (MALAYSIA) SDN BHD PHONE: 03-252-2211 FAX: 03-252-2131

KEYENCE (UK) LIMITED PHONE: 01908-696900 FAX: 01908-696777

KEYENCE (THAILAND) CO., LTD PHONE: 02-369-2777 FAX: 02-369-2775

KEYENCE DEUTSCHLAND GmbH PHONE: 0711-79 73 71-0 FAX: 0711-797 77 99

KEYENCE TAIWAN CO., LTD PHONE: 02-2627-3100 FAX: 02-2798-8925

KEYENCE FRANCE S.A. PHONE: 01 47 92 76 76 FAX: 01 47 92 76 77

KEYENCE KOREA CORPORATION PHONE: 02-563-1270 FAX: 02-563-1271

KEYENCE SINGAPORE PTE LTD PHONE: 392-1011 FAX: 392-5055 © KEYENCE CORPORATION, 1995 BL180-IM-4-0400 Printed in Japan

BL-180 Series User’s Manual

Specifications are subject to change without notice.