Page 69
APPENDIX
Page 70
A.1 Specifications
A.1 Specifications BL-180/185 Model Model (with connector) Scanning direction Light source/Light receiving element
BL-180
BL-185
BL-180SO(7030)
BL-185SO(7031)
Front
Side LED/CCD image sensor
Scanning distance
33 mm ± 10 mm1 (Using narrow bars of at least 0.19 mm in width)
Readable bar width
0.125 to 1.0 mm2
Maximum label width
80 mm3 (Using narrow bars of at least 0.19 mm in width)
PCS
0.45 or more (Reflectance of white part: 75% or more)
Scanning rate
500 scans/sec
Target code
CODE39, ITF, Industrial2-of-5, COOP2-of-5, Codabar, CODE128, EAN/UPC(A-E)
No. of readable digits
32 digits
Trigger input
Non-voltage input (contact or solid-state) TTL input is also possible.
Rated load
24 VDC, 100 mA
Ambient light
Sunlight, Incandescent lamp: 10,000 lux, Fluorescent lanp: 3,000 lux.
Current consumption Weight
300 mA max. Approx. 165 g
Approx. 180 g
OK/NG output
1. 33 ± 5 mm when the narrowest bar is less than 0.19 mm. 2. Readable bar width indicates the range of the narrowest readable bar. 3. 60 mm when the narrowest bar is less than 0.19 mm.
Output type Leakage current (at off)
0.1 mA max.
Residual voltage (at on)
0.5 V max.
Ambient temperature Relative humidity Vibration Power supply voltage
Serial interface
NPN open collector output
0 to 40°C 35 to 85% 10 to 55 Hz, Double amplitude in X, Y and Z directions, 2 hours respectively 5 VDC±5%1
Applied standard
EIA RS-232C port
Synchronization
Start-stop
Transmission code
ASCII
Baud rate
600 to 38,400 bps
Data length
7 bits/8 bits
Parity check
None/even/odd
Stop bit
1/2 bit
1. Use a stable power supply of 5 VDC ± 5%. The BL-U1 Special Power Unit is available as an option.
Note
62
The internal settings of the BL-180 series are stored in the EEPROM. (Rewritable up to 10,000 times)
Page 71
A.2 Reading Range Characteristics (Typical)
A.2 Reading Range Characteristics (Typical) Mount the BL-180 referring to the figure below. (The BL-185 provides the same characteristics as the BL-180.)
BL-180
80
60
Readable label width (mm)
* The readable label width means the bar code length including the bar code margins (quiet zones).
OK/NG STABILITY
10
10
33
Reading distance (mm)
5
5
•••Reading range when narrow bar width is not less than 0.125, less than 0.19 mm. •••Reading range when narrow bar width is 0.19 to 1.0 mm. (Measuring conditions) •The KEYENCE standard bar code is used. •Skew :-10° •Pitch : 0° •Tilt : 0°
Narrow bar width 0.125 to 0.19 mm (less than 0.19 mm) 0.19 to 1.0 mm
CAUTION
Reading distance
Maximum readable label width
33 ±5 mm
60 mm
33 ±10 mm
80 mm
The above range may be reduced depending on the bar code quality. Set the optimum reading position based on enough reading tests.
63
Page 72
A.3 Angular Characteristics (Typical)
A.3 Angular Characteristics (Typical) Mount the BL-180 referring to the data given below. (The BL-185 provides the same characteristics as the BL-180.)
Skew
Pitch
Tilt
-40° to -5°, +10° to +40° -40° to -5°, +10° to +40°
±15° ±15°
±10° ±15°
Narrow bar width 0.125 to 0.19 mm(less than 0.19 mm) 0.19 to 1.0 mm (Measuring conditions) • The KEYENCE standard bar code is used. • Reading distance: 33 mm
CAUTION
The skew angles of -5° to +10° are the specular reflection range (dead angles). In this range, bar codes cannot be read, or reading error may occur. Avoid mounting the BL-180 series at the above skew angles. Skew
Pitch _
0°
0° –
+
Receiver axis
OK/NG STABILITY
Tilt
+ 0° _
64
Receiver axis
+
Page 73
A.4 Dimensions
A.4 Dimensions BL-180 4
26
10
17
2 x 2-M3 Depth: 5 mm or less
47
20
80
55
Readable width
ø10 5 10
29
33
ø4.5 Cable length: 1.8 m
10
15.3 4
26
Receiver axis
17
BL-185 4
6
15
2 x 2-M3 Depth: 5 mm or less
36 55
20
80 Readable width
55
ø10 5
37 Receiver axis 6
12.5
33
10
ø4.5 Cable length: 1.8 m
4 15
36
65
Page 74
A.4 Dimensions BL-180 (with mounting bracket)
55 9 31 16
80 (Readable width)
55 33 47
7 33 Receiver axis
9
20
16 31
20 80 (Readable width)
33 47
7 33
°
31 (38)
Receiver axis
15.7
23.3
° 10
10
(36) 31
8 t=1.6
BL-185 (with mounting bracket) 33 4.4
20
9
55
80 (Readable width)
8
16 31 7 8
33 47
12.5
Receiver axis
° 31
(37)
10 t=1.6
66
4 Note: Detail of slot
11
Page 75
A.5 Example Program for Serial Communication
A.5 Example Program for Serial Communication The following is a example program that allows data communication and command communication. Type in a command and press [Enter] to send the data to the BL-180. Only the QUIT command can be sent by pressing [Q]. Set the BL-180 as follows: • Header: [STX] Delimiter: [ETX] • Handshaking protocol: No handshaking or PASS/RTRY handshaking 100 ‘***BL-180 SAMPLE PROGRAM********************************************* 110 CLS 3 120 DAT$=””:RD$=””:CM$=”” 130 OPEN “COM1:” AS #1 140 *BUFFCLR :’***CLEAR BUFFER******************************************** 150 A=LOC(1) 160 IF A<>0 THEN R$=INPUT$(1,#1) :GOTO *BUFFCLR 200 ‘ 210 *MAIN :’***MAIN ROUTINE*********************************************** 220 K$=INKEY$ 230 IF K$<>”” THEN GOSUB *COMMAND 240 A=LOC(1) 250 IF A<>0 THEN GOSUB *RECEIVE 260 GOTO *MAIN 300 ‘ 310 *Receive :’***RECEIVE DATA 320 RD$=INPUT$(1,#1) 330 IF RD$=CHR$(&H02) THEN RD$=”” :’RECEIVE STX 340 IF RD$=CHR$($H03) THEN GOSUB *BARCODE :RETURN :’RECEIVE ETX 350 IF RD$=CHR$($H0D) THEN GOSUB *RESPONSE :RETURN :’RECEIVE CR 360 DAT$=DAT$+RD$ 370 RETURN 400 ‘ 410 *COMMAND :’***SEND COMMAND******************************************** 420 IF K$=CHR$(&H0D) THEN *SEND 430 IF K$=”Q” AND CM$=”” THEN CM$=”QUIT”:GOTO *SEND 440 PRINT K$; 450 CM$=CM$+K$ 460 RETURN 470 *SEND 480 PRINT #1, CM$;CHR$(&H0D); :’SEND COMMAND 490 PRINT:PRINT CM$;”COMMAND IS SENT” 500 CM$=”” 510 RETURN 600 ‘ 610 *RESPONSE :’***DISPLAY RESPONSE DATA TO THE COMMAND******************* 620 PRINT DAT$ ;”IS SENT BACK” 630 DAT$=”” 640 RETURN 700 ‘ 710 *BARCODE :’***DISPLAY BAR CODE DATA*********************************** 720 PRINT DAT$ ;”IS READ” 730 DAT$$=”” 740 RETURN
67
Page 76
A.6 Troubleshooting
A.6 Troubleshooting If a problem occurs during operation, please check the following troubleshooting notes first. If you cannot fix the problem, contact KEYENCE or your nearest dealer.
Bar codes cannot be read. Check whether the light source LED is ON. When using a power supply other than the BL-U1 special power supply unit, confirm that the power supply voltage and capacity is within 5 VDC±5% and 300 mA. Check the wiring of the power supply unit and the timing input terminal (see p. 11).
CAUTION
Connecting the power supply unit with the reverse polarity may damage the BL series. If the BL-180 does not operate, contact KEYENCE. Check the bar code setting (type, No. of digits). Check the following parameters using the setup software. • Bar code type, No. of digits. • Setting of the check digit inspection (enabled or disabled) • Setting of the label orientation-specified reading
Note when using CODE39 or Codabar, include the start/stop characters and check digit in the number of digits. For Code128, see page 70. Check the distance and angle between the BL-180 and bar code. Check the distance and angle while referring to “Mounting angle and mounting distance” on page 7. Check the bar code margins (quiet zones). A bar code requires the right and left margins to be at least 10 times wider than the narrow bar width. If the bar code margins are too narrow, it may not be read. Check the bar code label length. The bar code label length is the lateral length of a bar code including the right and left margins (quiet zones). When the narrow bar width (the minimum bar width) is 0.125 to 0.19 mm (less than 0.19 mm), the readable label length is up to 60 mm length. When the narrow bar width is 0.19 to 1.0 mm, the readable label length is up to 80 mm. Check the bar code. A bar code with blurred sections, defects or stains may not be read correctly. Bar codes printed with dot matrix or ink jet printers are prone to such problems.
68