Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 14

Pro4000 FieldBook, pages 21 to 30

Pages 21 to 30 of 140

The original document is the PDF (4.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Juniper Systems Pro-4000

Page 21 read from a scan by OCR; it may hold reading errors

Special Keys and Key Sequences

The keyboard options in black lettering are operational unless a GREEN or BLUE shift key is depressed. The green and blue key sequences and their functions are listed below (unless otherwise specified, press the colored key first, then the other key/s listed):

Function Key Sequence Select an upper character BLUE key + appropriate key (shown in BLUE)

Control Break <CIRL> + BLUE key + <SCR-LK> Pan display window in GREEN key + any arrow key the direction of the arrow

Toggle auto-panning on oz GREEN key + (INS) off

Decrease LCD contrast GREEN key + <. > (or <->) Increase LCD contrast GREEN key + <D> (or <+>) Toggle display backlight GREEN key + <BS> on or off

Turn low power beeper off GREEN key + <ESC>

Performahard reset(reboot) <On/Off> (hold down for 8 to 10 seconds

Green Shift Key Usage

To access the keyboard options printed in green lettering, press and release the GREEN shift key followed by the key with the desired green-lettered option. Io activate several green-lettered options before returning to standard mode, continue to hold the GREEN shift key down while you press the keys with the desired green-lettered options. Once the GREEN shift key is released, the keyboard reverts back to the standard mode

Blue Shift Key Usage

To access the keyboard options printed in blue lettering, press and release the BLUE shift key followed by the key with the desired blue-lettered option. To activate several blue-lettered options before returning to standard mode, continue to hold the BLUE shift key down while you press the keys with the desired blue-lettered options. Once the BLUE shift key is released, the keyboard reverts back to the standard mode. To repeat a BLUE key character, press and release the BL UE key then hold down the character to be re-peated

Hardware Features 2-5

Page 22 read from a scan by OCR; it may hold reading errors

4 Membrane Keyboard

The membrane keyboard has 39 keys color coded by function, a separate numeric keypad, 10 function keys, and special DOS control keys. The alphabetic keys are accessed through the BLUE shift key or by putting the keyboard in alpha lock mode. The keys on the membrane keyboard are larger than those on the elastomeric keyboard and easily accommodate gloved fingers. The membrane surface is very durable and is extremely resistant to tears and punctures. Snap domes under the keys provide tactile feel when pressed r Fi

(G @) (H #) (BKsP) .7) (8) U9) [Ese ft$) fs%) (K*) (Paup (4) 5) 6) t | (L&) (m*) (N-) (Pann)

(1) L279 L389 LY (O() (P)) (Home) (END ) GREEN 0 | ' <| > Shift Key aa Ww, ~ BLUE, Bae W | ENTER ShiftKey| Ss ‘e a4 C5 BKLT| |, ry ; ’ w<) (x> Z1 (ass) | | 7 ) [er] srt) (8) vor Je \

Membrane Keyboard

Nees

Page 2-6 Hardware Features

Page 23 read from a scan by OCR; it may hold reading errors

Keyboard Modes

The membrane keyboard has two modes: standard and alpha lock. In standard mode (default) all options in black lettering are operational, unless a BLUE or GREEN shift key is depressed. In alpha lock mode, the alphabetic characters are operational unless a BLUE or GREEN shift key is depressed. Details on how the keyboard works in these modes follow.

Special Keys and Key Sequences

The keyboard options available on the elastomeric keyboard are also available on the membrane keyboard by using the BLUE and the GREEN shift key sequences (except F11, F12, PR-SCR, and SCRLK). The BKL T: (backlight), DIM (dim), and BRT (bright) keys are unique to the membrane keyboard

The special keys and key sequences and theix functions are listed below (press the colored key first, then the key listed after the +):

Function Key Sequence Select a blue character BLUE key + appropriate key Select a green character GREEN key + appropriate key Toggle alpha lock mode Press GREEN and BLUE keys on o1 off simultaneously Temporarily override BLUE key + appropriate key alpha lock to use a black key (when alpha lock is on) Temporarily override GREEN key + appropriate key alpha lock to use a green key = (when alpha lock is on) Pan display window in GREEN key + any arrow key the direction of the arrow Toggle auto-panning on or GREEN key + <INS> off Decrease LCD contrast GREEN key + <DIM> Increase LCD contrast GREEN key + <BRT> Toggle display backlight <BKLT> on or off Turn low power beeper off GREEN key + <ESC> Perform a hard reset (reboot) <On/Off>

(hold down for 8 to 10 seconds)

Hardware Features 2-7

Page 24 read from a scan by OCR; it may hold reading errors

Blue Shift Key Usage

To access the keyboard options printed in blue lettering, press and release the BLUE shift key followed by the key with the desired blue-lettered option. To activate several blue-lettered options before returning to standard mode, continue to hold the BLUE shift key down while you press the keys with the desired blue-lettered options Once the BLUE shift key is released, the keyboard reverts back to the standard mode.

Green Shift Key Usage

To access the keyboard options printed in green lettering, press and release the GREEN shift key followed by the key with the desired green-lettered option. To activate several green-lettered options before returning to standard mode, continue to hold the GREEN shift key down while you press the keys with the desired green lettered-options. Once the GREEN shift key is released, the keyboard reverts back to the standard mode

Alpha Lock Mode

If you want to enter alpha text without having to hold down the BLUE shift key, you can place the keyboard in alpha lock mode by depressing the BLUE and the GREEN shift keys simultaneously When alpha lock is activated, you hear a rising tone. Io leave alpha lock mode, depress the BLUE and GREEN shift keys simultaneously again When alpha lock is deactivated, you hear a falling tone.

“ Note: Black lettered ARROWS and CTRL, ALT, SHIET, and ENIER keys continue to operate as though you were not in alpha lock mode

Overriding Alpha Lock to Access a Black or Green-Lettered Option

You can temporarily override the alpha lock mode to access a black-lettered option by pressing and releasing the BLUE shift key followed by the key with the desired black-lettered option. You automatically return to alpha lock mode To activate several black-lettered options before returning to alpha lock, continue to hold the BLUE shift key down while you press the keys with the desired black-lettered options. You automatically return to alpha lock mode once the BLUE key is released (release it before pushing your last black-lettered key). If you enter a key in error, depress the back space (BKSP) key to erase the entry.

You can access a green-lettered option while in alpha lock mode by pressing and releasing the GREEN shift key followed by the key

Page 2-8 Hardware Features

Page 25 read from a scan by OCR; it may hold reading errors

with the desired green-lettered option. You automatically return to alpha lock mode. To activate several green-lettered options before returning to alpha lock, continue to hold the GREEN shift key down while you press the keys with the desired green-lettered options. You automatically return to alpha lock mode once the GREEN key is released (release it before pushing your last green-lettered key). If you enter a key in error, depress the backspace (BKSP) key to erase the entry

A Typing Extended Characters

You can access characters that are not available on the keyboard by pressing the <AL I> key and typing the associated three digit ASCII character code on the keyboard. For example, you would press <ALT> <248> to access a degree symbol °. A list of extended characters can be found in the Technical Reference.

This feature can be enabled (default) ot disabled through the extended BIOS functions (Refer to Section 8, Programming Guide, Extended BIOS Functions )

A Performing a Hard Reset

To perform a hard reset (reboot), hold down the <On/ Off> key for 8 to 10 seconds (just long enough for the screen to clear). Do not hold the <On/Off> key down during the reboot process.

+ Note: When you turn the Pro4000 on or off, there is no “beep” when you press the <On/Off> key (other FieldBook models do have that feature). Also, it is normal for a horizontal line to appear briefly on the screen.

Hardware Features 2-9

Page 26 read from a scan by OCR; it may hold reading errors

Display and Full Screen

A Display

The display window is 3" wide x 2" high, allowing you to view 24 characters x 16 lines of information. A scratch-resistant, low-glare finish has been applied to the display bezel which covers the display. The display is a CGA extended temperature display.

(ss >

S=; HarvestMaster”

(

FieldBook

U Pro4000 )

Display Features: - Gray Scale: with this setting, you can use up to 16 shades of gray. The normal setting is black and white

Shade Mapping: converts colors and gray shades into black and white to achieve the best contrast

- Contrast: the display contrast can be increased or decreased Heater: the display heater allows you to use the Pro4000 in temperatures at or below freezing

Backlight: the backlight enhances visibility

- Auto-Panning: the display window can be set up to automatically pan with the cursor (see Auto-Panning later in this section)

Page 2-10 Hardware Features

Page 27 read from a scan by OCR; it may hold reading errors

- Video Modes: There are two video modes: text mode and graphics mode. The program running on the Pro4000 dictates which display mode is used. For example, if you were running LandMark GPS and drawing a map on the Map screen, you would be in graphics mode. When the Pro4000 is in graphics mode, panning is not supported. For more information about Video Modes, refer to Section 8, Programming Guide.

The display features can be enabled, disabled, or adjusted through the System SetUp Program (refer to Section 4, System SetUp Program, Keyboard/Display Screen for more details). Some display features can also be adjusted using special key sequences as shown in the chart below:

Key Sequence, Key Sequence, Display Feature Elastomeric KB Membrane KB Increase Contrast GREEN + <+> GREEN + <BRT> Decrease Contrast GREEN + <-> GREEN + <DIM> Backlight Toggle GREEN +<BS> <BKLT>

On and Off

Auto-Panning Toggle GREEN+<INS> GREEN + <INS> On and Off

A Full Screen

The Pro4000 has a full screen stored in memory that is 80 characters wide by 25 lines deep. Because the size of the Pro4000 display window is 24 characters x 16 lines, you can only view a portion of the full screen at a time.

Pro4000 Display Window

Fuil Screen in

24 characters wide Pro4000 Memory x 16 lines deep

80 characters wide x 25 lines deep

Hardware Features 2-17

Page 28 read from a scan by OCR; it may hold reading errors

You can view any part of the full screen by panning horizontally and vertically. Panning can be done automatically using Auto-Panning or manually using GREEN key + arrow key combinations.

Auto-Panning

When Auto-Panning is enabled, the screen automatically shifts (pans) as the cursor moves beyond the visible window. Roughly 40% of what you see in the new display window is part of the previously displayed screen, while 60% is the new area the cursor moved into.

This > screen When the screen panned pans, you still horizon- Be bee) a iets tally one Big UCHeE ek position.

\ y,

When Auto-Panning is disabled, the screen does not shift as the cursor moves beyond the visible window. The display screen can be shifted by panning manually or through program control.

The Auto-Panning default is enabled It can be turned off in the System SetUp Program (see Section 4, System SetUp Program, Keyboard/ Display Screen). You can also toggle auto-panning on and off by pressing the GREEN shift key + <INS>.

Panning Manually

You can manually move the display window around the full screen by pressing the GREEN key followed by the desired arrow key. (See Keyboard, Green Key Usage, earlier in this section for details.) The visible display pans in the direction of the arrow. As with Auto- Panning, roughly 40% of what you see in the new display window is part of the previously displayed screen, while 60% is the new area (see graphic above). The cursor remains in its original position; it does not follow the window.

Page 2-12 Hardware Features

Page 29 read from a scan by OCR; it may hold reading errors

Communication Ports

A 9 Pin Serial Communication Ports

A Pro4000 has two 9 pin serial communication ports (COM] and COM2), allowing the simultaneous operation of two serial devices such as printers, modems, and bar code wands. The wall mount charger is connected to COM 1 to trickle charge the Pro4000. A serial communication cable (9 pin to 9 pin) for use with serial devices is available from HarvestMaster.

9 Pin D Connector Pinouts

COMI

Battery Charger Input or Data Carrier Detect (DCD) Input Receive Data (RCD)

Transmit Data (TXD)

+5V Switched Supply or

Data Terminal Ready (DTR) Output Ground (GND)

Data Set Ready (DSR)

Request Io Send (RTS)

Clear Io Send (CTS)

Ring Indicator

Data Carrier Detect (DCD) Receive Data (RCD) Transmit Data (IXD)

Data Terminal Ready (DTR) Ground (GND)

Data Set Ready (DSR) Request To Send (RTS) Clear To Send (CTS)

Ring Indicator venewwernB waonNan moO ND bo

Limitations

If you want to connect a bar code wand to COM2, it might need its own power source because COM2 may not supply enough power for the wand ,

Hardware Features 2-13

Page 30 read from a scan by OCR; it may hold reading errors

The Pro4000 design uses power much more efficiently than previous FieldBook models. More than double the amount of operating time can be realized in the field depending on your application. The Auto Suspend and Power Management features help to conserve power Maintaining the battery pack and backup supply is also much simpler

These battery design features are discussed in detail in this section of the manual.

A Batteries and Backup Power Supplies

There are three batteries and a backup capacitor associated with the Pr04000:

Q@ NiCad Battery pack (main power source)

Q Internal lithium backup battery (powers the real time clock and CMOS RAM)

Q Super capacitor that serves as the RAM backup (maintains the RAM while you change the battery pack)

Q SRAM memory card battery (maintains the card memory when the card is not powered by the Pro4000)

The batteries and the super capacitor are discussed in detail in this section,

A Battery Pack

The Pro4000 is powered by a rechargeable nickel-cadmium (NiCad) battery pack with a heavy-duty option. A comparison of these batteries is shown below. The stated operating times are based ona typical application where the Pro4000 is running at 33 MHz, the Power Manager is on, data are being entered manually on the keyboard, the backlight is used 10% of the time, and processing time is 20% The actual operating time could vary from as little as 5 hours to as much as 80 hours, depending on your program and how the system is set up.

Standard Pack Heavy-Duty Pack Capacity 1,700 mA hours 3,400 mA hours Operating Time 12 to 18 hours 24 to 36 hours Weight 5 Ibs 1.1 Ibs

Page 2-14 Hardware Features