Page 121
Programming Guide
Page 8-25
Keyboard Legend
Normal Blue
System Scan Codes (hex)
Character Codes
AH/AL
(hex)
Normal
Shift
Ctri
Alt
Y
15
15/79
15/59
15/19
15/OD
60
28/22
28/22
28/08
Z
2C
2C/7A
2C/5A
2C/1A
2C/BO
28
28/27
28/27
28/0
Space
39
39/26
39/2
39/20
39/28
Shift
2A
CapsLk
3A
Red
7F
Page 122
Page 8-26 Programming Guide
Page 123
Appendix
Operating Instructions for Charging Accessories
Q SafeCharger Battery Pack Charger (1 SmartCharger Battery Pack Charger
Page 124
Page A-2 Appendix: Charging Accessories
Page 125
SafeCharger Battery Pack Charger
The SafeCharger is a timed charger with two functions:
Oi Recharging the Pro4000 battery pack over a12 hour period (overnight charge rate).
O Maintaining the charge of the battery pack and backup battery during periods of disuse (trickle charge mode).
A How to Use the SafeCharger 1) Leave the battery pack attached to the Pro4000. 2) Plug the AC charging adaptor into a 110V (or 220V) AC outlet
3) Insert the charger's connector into the 9 pin connector (COM1) on the Pro4000 and tighten the thumbscrews.
Green Red
LED: LED: AC Adaptor Charge Overnight
Indicator >=Ope-O - ] < Rate aa / Indicator
Manual Trickle Charge Set Button | |
Green and Red LEDs
There is a red and a green LED (light emitting diode) on the face of the connector. When you plug the power adaptor into the wall socket and attach the SafeCharger to COM1 on the Pro4000, both LEDs turn on.
Green LED
The green LED is the charge indicator. When it is on, everything is connected correctly and the Pre4000 is being charged If the green LED does not come on, it is not charging. Make sure the battery is installed, the charger is connected to COMI, and the AC outlet you plugged the power adaptor into is energized.
Red LED
Appendix: Charging Accessories Page A-3
Page 126
The red LED is the overnight rate indicator. When it is on, the charger is in the overnight charge rate. The Pro4000 is given a full charge over 12 hours. The charger then automatically switches to trickle charge mode and the red LED turns off. You can leave the Pro4000 in trickle charge mode continuously without damaging the batteries, allowing you to keep it charged over the weekend and during inactive periods.
Manually Switching to Trickle Charge Mode
You can manually switch the SafeCharger to trickle charge mode by gently inserting a pointed object into the trickle charge set button found between the LEDs. The green LED stays on and the red LED turns off, indicating that the charger is in trickle charge mode.
Note: If there is a power failure which lasts for more than a few seconds, the SafeCharger will switch back to overnight charge mode for 12 hours then return to trickle charge mode.
Page A-4 Appendix: Charging Accessories
Page 127
SmariCharger Battery Pack Charger
The SmaztCharger fast-charges Pro4000 battery packs It also provides a deep discharge cycle for long-term battery maintenance.
The SmartChargetr charges a fully discharged battery pack in about 2 hours. It takes approximately 8 hours to discharge a fully charged pack and about 3 hours for a pack that is 50% charged.
A SmartCharger Features
Q Fast Charge Capabilities
Q Selectable Discharge Option
Q LED Status Indicators
Q 110 Volt and 220 Volt Powe Supply Options
4 Components A SmartCharger includes the following components:
1) Model PW-SC SmaztCharger 2) Power Supply Adaptor: you should have one of the following: PW-WB110 110 Volt Power Supply Adaptor
PW-WB220 220 Volt Power Supply Adapto1 PW-CIG-SC Cigarette Lighter Adaptor Note: The SmartCharge: will work with all of the power supply options listed above without any internal adjustments.
3) User's Manual
A Toggle Switch and LEDs
Located on the front panel of the SmartCharger are 3 red LEDs (light emitting diodes) and a toggle switch The SmartCharger label gives you a basic explanation of the LED and switch features
Appendix: Charging Accessories Page A-5
Page 128
Refer to the chart below for more details.
LED/Switch | Status | Meaning
Power LED On Power applied.
Off No power applied
Flashing | SmartCharger failed during self test and
Rapidly {| may need to be repaired. Contact our customer service department.
One ERROR. The pack is not taking a charge.
Flash The battery cells may be shorted.
Two ERROR. The pack voltage was too low
Flashes | after the charge cycle was complete The battery cells are probably shorted
Three ERROR. The terminal charge voltage is too
Flashes | high. This usually means that the battery has a high internal resistance, a signal that the battery's useful life is about over.
Four ERROR Ihe SmartCharger is unable to
Flashes | discharge the battery pack and may need to be repaired Contact our customer service department
Charge LED On Fast-charge cycle underway.
Off Fast-charge finished; trickle charge underway; or, no battery pack attached.
Flashing | ERROR. SmartCharger is out of allowable operating temperature range (+50° to 104° F, +10° to 40° C) It will resume charging the pack once the temperature is within the allowable range (after a 15 minute delay).
Discharge LED] On
Off Flashing
Discharge cycle underway. Discharge finished o1 not enabled.
ERROR SmartCharger is out of allowable operating temperature range (+50° to 104° F, +10° to 40° C) It will resume discharging the pack once the temperature is within the allowable range (after a 15 minute delay)
Switch
Discharge
To begin discharge cycle: press switch to the right during fast charge cycle.
To cancel discharge cycle: press switch to the right during discharge cycle.
Page A-6
Appendix: Charging Accessories
Page 129
A Installation
Plug the power supply adaptor into a power outlet (110 VAC for the PW-WB110, 220 VAC for the PW-WB220). Plug the connector from the power supply adaptor into the connector located in the back of the SmartCharger. When power is applied, the Power LED turns on after a few seconds and remains on as long as there is power. (If the power LED flashes, refer to the chart on the previous page for an explanation ) The SmartCharger is now ready to charge a Pro4000 battery pack,
+ Important Note: Make sure the SmartCharger is plugged in before a battery pack is inserted. Do not operate the SmartCharger in extreme hot or cold conditions. Typical room temperature is ideal (+50° to 104° F, +10° to 40° C). Both the SmartCharger and the battery pack need to be within this temperature range, or damage to the battery pack could occur.
A Normal Charge Cycle
The SmartCharger automatically runs a normal charge cycle without discharging the battery. Ihe time required for a normal charge depends on how deeply the battery pack was discharged prior to being placed on the SmartCharger. For a fully discharged pack (standard or heavy-duty), a charge cycle takes approximately 2 hours.
To start the normal charge cycle, simply slide the battery pack onto the SmartCharger After a few seconds, the Charge LED comes on. When the Charge LED goes off, the pack is charged and ready to use. (If the charge LED is flashing, refer to the chart on page 4.)
After the pack is fully charged, the SmartCharger goes into a trickle charge mode, maintaining the fully charged state of the pack until it is removed and preventing the batteries from over-charging.
A Discharge Cycle
You should periodically deep discharge battery packs before charging them. It takes approximately 8 hours to discharge a fully charged pack and about 3 hours for a pack that is 50% charged To start the discharge cycle, follow these steps:
1) Insert the pack and wait for the Charge LED to come on.
2) Press the Discharge On/Off switch to the right until the Discharge LED comes on. Release the switch If you change your mind about running the discharge cycle, press the switch to the right
Appendix: Charging Accessories Page A-7
Page 130
again until the Disharge LED goes off and the Charge LED comes on. Note: If the pack is already discharged, toggling the switch will not cause the Discharge LED to come on. This protects the pack from over-discharging,
3) The SmartCharger senses when the pack is discharged and begins the charge cycle automatically. The Discharge LED goes off and the Charge LED comes on.
We recommended that the discharge cycle only be used periodically. Deep discharging the battery pack each time the pack is charged reduces the life (number of charge/discharge cycles) of the pack. If the packs are charged each day and only slightly discharged to about the same level, then you should deep discharge the packs about once every 1 to 2 months.
Battery Discharge Characteristics
NiCad batteries have extremely stable voltage characteristics during discharge, and the voltage drop occurs suddenly at the end of discharge. The standard end voltage (discharged battery) adapted for NiCad batteries is 1.0 volts per cell. Pro4000 battery packs have 5 cells in a series so that when the voltage level reaches 5.0 volts, the batteries are completely discharged in terms of their effective use. During the discharge cycle, the SmartCharger discharges the batteries down to approximately 5.0 volts.
For more details on the Pro4000 battery pack and backup batteries, refer to Section 2, Hardware Features, Batteries
4 An Important Note About Power Interruptions
The SmartCharger must be reset if a battery is installed and power is interrupted. Instructions on how to reset the SmartCharger are given below:
1) If the SmartCharger is plugged in, unplug it as soon as possible after the power is interrupted.
2) Remove the battery pack from the SmartCharger.
3) Plug the SmartCharger in.
4) Re-install the battery pack onto the SmartCharger
5) If the pack was being discharged, start the discharge cycle again
Page A-8 Appendix: Charging Accessories