Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 8 of 20

Allegro DOS Owner's Manual: Chapter 4 MS-DOS Operating System, pages 55 to 64

Pages 55 to 64 of 166, from Allegro DOS Owner's Manual

The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Juniper Systems Allegro-DOS

Page 55

▲ Chapter 4 MS DOS Operating System

Chapter 4

MS-DOS Operating System

MS-DOS Operating System Overview Setting Up Communication Lynx Windows File Management Utility FileScout DOS File Manager Text Editor Terminal Emulation Program System Setup Program Startup Files DOS Utility Programs and Device Drivers Make Space Utility Program Serial Printing Utility Program

Allegro DOS Owner’s Manual

55

Page 56

56

Allegro DOS Owner’s Manual

Page 57

MS-DOS Operating System Overview This Chapter describes the operation of the Allegro using the MS-DOS™ 6.22 operating system.

▲ Running DOS You can operate the Allegro by issuing standard DOS commands from the DOS prompt or through a file management program called FileScout (described in detail later in this chapter).

▲ Programs for the Desktop PC and the Allegro Desktop PC Program The Allegro Distribution CD-ROM includes the Lynx™ Windows File Manager for installation onto your desktop PC. To run Lynx, the desktop PC must be running Windows 95 or higher and must have at least one serial port. To install Lynx on your desktop PC, insert the Allegro Distribution CD-ROM into your computer and select Install Lynx option. Follow the instructions given to you. The Lynx icon appears in the Start menu when installation is complete. ❖ Note: If you have previously installed Lynx on your desktop PC we recommend that you uninstall it and install the updated version included on the Allegro DOS Distribution CD-ROM. Allegro Programs The following DOS programs are factory-installed on the Allegro: FileScout DOS File Management Utility Text Editor Terminal Program Commonly Used DOS Commands The Lynx program, all of the Allegro programs, and the full set of the DOS commands are included on the Allegro Distribution CD-ROM.

Allegro DOS Owner’s Manual

57

Page 58

Setting Up Communication Communication functions are handled by the following programs: On the desktop PC: Lynx™ File Management Utility On the Allegro: FileScout™ DOS File Management Utility

▲ Establishing Communication Between Computers Follow the steps listed below to set up communication between the desktop PC and the Allegro: 1) Connect one end of the serial communication cable to the serial port on the desktop PC and the other end to either one of the serial communication ports on the Allegro (COM1 or COM2). 2) Turn on both the desktop PC and the Allegro. 3) On the desktop PC, start Lynx from the Windows Start Menu. On the Allegro, run FileScout by typing “FS” at the DOS prompt and press ENTER. Note: If you are using Windows XP operating system, start Lynx by double-clicking on the Lynx.bat file Icon located on your computers desktop. If the icon does not exist, you can download the file from our website at www.junipersys.com. 4) On the desktop PC, set up the communication port from Lynx by selecting the Transfer|Select COM Port menu option. Select the port that the communication cable is connected to (COM1, COM2, etc.). Beneath the Remote screen a status box indicates which communication port has been set up on the PC. 5) On the Allegro, if you are using COM1 (the default) as the communication port, no additional set up is required. If you are using COM2, press F5 Xfer from the FileScout menu to view the Transfer menu. Press F1, COM Port and select COM2. 6) To establish communication between the desktop PC and the Allegro, click on the Lynx Connect shortcut button or select the Transfer/Connect to Remote menu option. As communication is being established, the Connect button rotates and the Status box at the bottom of the Remote screen displays: trying…trying… trying… Comm established…Connected. If communication is not made, an error message appears on the screen telling you that communication was not established. If this happens, make sure you have properly prepared the Allegro and the PC to communicate and try connecting again. 58

Allegro DOS Owner’s Manual

Page 59

Once communication is established, the drives, folders, and files located on the Allegro are shown on the Lynx remote screen on the desktop computer. On the Allegro FileScout status line, the word Connected blinks every second to indicate that a connection is made with the computer. Refer to the information about Lynx later in this chapter for details.

▲ Adjusting the Allegro Communication Parameters In most cases, you can use the default communication parameters on the Allegro; no adjustments are required. If you need to make adjustments or are having trouble establishing communication between the Allegro and the desktop PC and need to check the settings, refer to the description of the parameters below. From FileScout press F5 Xfer to view the Transfer screen. The following functions are listed at the bottom of the screen: Function F1 = COM Port F2 = Baud F3 = Cmd F4 = Recv F5 = Send F6 = Lynx

Default COM1 115.2K

On

Description Set Up Communication Port Select Baud Rate Access the Commands Receive Files From PC Send Files to PC Communication Mode

To change a setting, press the number associated with it or highlight the desired setting using the up and down arrow keys and press ENTER). F1 - COM Port Press F1 to select COM1 or COM2. The active port is listed in the upper right corner of the FileScout screen. F2 - Baud We recommend that you leave the Allegro in “auto baud rate detection mode.” In this mode, the Allegro establishes communication between the PC and the Allegro at 115.2 K baud (required to use Lynx). To change the baud rate, press F2 and make a selection. F3, F4, F5 When the Allegro is communicating with Lynx on the desktop computer, the FileScout Transfer functions F3, F4, and F5 are not used.

Allegro DOS Owner’s Manual

59

Page 60

F6 - Lynx To communicate with Lynx, the Allegro needs to be in the Lynx communication mode. When Lynx mode is on, the word Lynx is displayed at the top of the FileScout menu along with the active port as shown below: FileScout v1.0 Lynx – COM1 When the Allegro is in Lynx mode, it checks at regular intervals to see if it is linked to a computer. When it detects a connection, the Allegro is treated as a remote computer by the desktop computer. To turn Lynx mode on or off, Press F6 and make a selection. ❖ Note: Auto Suspend does not work while you are connected to Lynx on your desktop PC. See System Setup Program, Power Management Screen, Auto Suspend later in this chapter of the manual for details. Communicating with Other Desktop PC Programs Some programs have integrated PC communication modules you will use instead of Lynx. DataLink and LandMark PC are two examples. The FileScout Transfer screen has three functions that you may use with these programs: F3: Command F4: Receive F5: Send Refer to the User’s Manual for the program you are using for information on how to proceed.

60

Allegro DOS Owner’s Manual

Page 61

Lynx Windows File Management Utility Lynx is a Windows file management utility that runs on a desktop PC, allowing you to easily transfer files between your desktop PC and the Allegro Field Computer. Additional file management functions that can be performed remotely on the Allegro from your PC include: Creating and deleting files or folders Moving or copying files within the remote or local computer Viewing the contents of folders, the C: drive, or PC cards

▲ Lynx Screens When you start Lynx from your Windows Start Menu or desktop icon, two Windows Explorer™-type screens are displayed. The top screen (Local) displays the contents of your PC. The bottom screen (Remote) displays the contents of the Allegro after a connection is established. A sample screen is shown below: The Lynx display has the following features: 1) File, Edit, Transfer, and Help functions. 2) A tool bar with shortcut buttons is located between the local and remote screens. 3) Beneath the remote screen are four boxes that provide you with the following information: status, active communication port, bytes free on the Allegro, and file transfer progress.

Allegro DOS Owner’s Manual

61

Page 62

▲ Lynx Menu Options Once communication has been established between the Allegro and the PC, you can use the Lynx menu options. Shortcut buttons are available for some of these options. The shortcuts are described later in this chapter. File Menu Options The following are available on the File Menu: New Folder Delete Filters Exit New Folder Creates a new folder or sub-folder on the local or remote computer. A dialog box is shown where you type in the new folder name. Delete Deletes a file or a folder. To do this compete the following steps: 1) Highlight the file or folder to be deleted. 2) Select the delete menu option or the delete shortcut key. 3) Press the desired key to confirm that the file you selected should or should not be deleted, as outlined in the delete dialog box. Filters Allows you to view selected file types. You can set a filter for both the local and the remote computer separately. You can use a wildcard (*) in the filter specification. For example, if you want to use Lynx to transfer files from the Allegro with the file extension .dat, you would set the filter for the remote to *.dat in the remote filter dialog box. The file list for the remote display would list files with the extension .dat. All other files would not be shown on the display. Exit Exits Lynx on the PC. Prior to exiting Lynx disconnect the communication link between the PC and the Allegro using Transfer/ Disconnect or by pressing the Disconnect button.

62

Allegro DOS Owner’s Manual

Page 63

Edit Menu Options The edit options follow standard Windows protocol. Highlight the file or folder you want to perform the editing function on. You can select multiple files with Select All or by holding down the Shift or Ctrl key as you highlight each file. Choose the editing option you want to perform in one of the following ways: 1) Select the option from the Edit Menu (Edit/Cut for example). 2) Press the appropriate control key shortcut (Ctrl X for example). The following are options available on the Edit Menu: Cut Copy Paste Select All Cut (Ctrl X) Cuts a file or folder. When a file or folder is cut from the remote display, the file disappears from the file list on the active display. When the file is pasted (moved) to the new location, the file list is updated. If you cut the file but you neglect to paste it, the file is still on the drive from which it was cut. Copy (Ctrl C) Copies a file or folder. Paste (Ctrl V) Pastes a file or folder from the clipboard. Select All (Ctrl A) Selects all the files or folders on the local or remote screen. ❖ Note: The edit menu options can be used to cut, copy, and paste files or folders within either the local or remote screen, but not between them. Use the transfer menu options, or arrow shortcut buttons for moving files between computers. Transfer Menu Options The following options are available on the Transfer Menu: Connect to Remote Send to Remote Receive from Remote Cancel Transfer Disconnect Select COM Port Allegro DOS Owner’s Manual

63

Page 64

Connect to Remote Establishes a connection between the PC and the Allegro. Send to Remote Sends a file from the PC (Local) to the Allegro (Remote). To do this, complete the following steps: 1) Highlight the file or files to transfer. You need to rename files that are more than eight characters long before you transfer them to the Allegro. 2) Select the Send to Remote menu option or press the shortcut button to send the file(s). On the Lynx screen the Status box indicates the transfer status and the Progress bar displays the file transfer progress. The file list on the Allegro is updated after file transfer is complete. Receive from Remote Sends a file from the Allegro (Remote) to the PC (Local). To do this, complete the following steps: 1) Highlight the file or files to transfer. 2) Select the Receive from Remote menu option or press the shortcut button to send the file(s). On the Lynx display the Status box indicates the transfer status and the Progress bar displays the file transfer progress. The file list on the PC is updated after file transfer. Cancel Transfer This function is used to cancel a file transfer after it has been initiated. Disconnect Disconnects the communication link between the PC and Allegro. This action tells the Allegro to stop waiting for additional commands from the PC. Pressing the Esc key on the Allegro returns to normal function. If you need to communicate with more than one Allegro, you must click the Disconnect button before switching the serial cable to the next Allegro. When the communication link between the Allegro and the PC is disconnected, the Lynx Remote screen is cleared. On the Allegro, the Status line on the FileScout screen no longer displays Connected every second. 64

Allegro DOS Owner’s Manual