The text of a manual · part 6 of 20
Allegro DOS Owner's Manual: Chapter 2 Hardware Components, pages 40 to 48
Pages 40 to 48 of 166, from Allegro DOS Owner's Manual
The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Juniper Systems Allegro-DOS
Page 40
2) Insert three fresh AA alkaline batteries, taking care to orient them correctly (only use alkaline batteries). Always replace all three batteries at once. Note: For best results, we recommend that you use the new types of alkaline batteries such as the Duracell Ultra™ and Energizer Titanium™.
Note: Do not use re-chargeable AA battery adapters. The battery life of three re-chargeable batteries is not cumulative. This means that if a battery equals 1700 milliamp hours (mAh) then three batteries still equals 1700 mAh and not 5100 mAh. 3) Slide the door to the alkaline holder back into place, making sure it snaps securely shut. 4) The Allegro battery compartment is accessed through a door in the back of the case. To open the compartment door, push up on the release latches on the sides of the case. The door pops open. Remove the NiMH pack or alkaline holder by sliding it to the left and pulling it out. 5) Open the door to the alkaline battery holder by pressing in on both tabs with your index finger and thumb as shown. 6) Place the alkaline battery holder in the left side of the Allegro battery compartment. Put gentle pressure on the holder while sliding it all the way to the right. 7) Press down on the Allegro battery compartment door to close it. The latches should automatically lock the door into place and seal the compartment. Make sure that the slide latches are completely closed. 8) While you are using the Allegro Field PC, occasionally check the battery LED indicators above the Allegro display. When the battery power gets low, replace the alkaline batteries or insert a NiMH pack.
40
Allegro DOS Owner’s Manual
Page 41
Important Information Regarding the Use of Alkaline Batteries The Allegro Field PC is designed to be used with the rechargeable NiMH battery pack that came with the unit. The alkaline battery option should be considered as a backup to the NiMH battery pack, not as the main source of power for an extended period of time. Alkaline batteries have a lower capacity and a higher resistance than NiMH batteries. Thus the battery life and performance of the Allegro are reduced when alkaline batteries are used. The Allegro runs as described below: The clock speed automatically switches down to a maximum speed of 33 MHz The display heater cannot be used As the batteries are drained, the Allegro automatically switches to a slower clock speed and limits the backlight intensity to further reduce power consumption and prevent the unit from turning itself off because of power demands Battery life ranges between 2 and 8 hours (this is highly dependent on the temperature) If you have been using alkaline batteries in the Allegro and switch to a NiMH battery pack, the clock speed and backlight brightness settings automatically return to the levels they were previously set at. Storing the Allegro During Inactive Periods To protect the Allegro and your files during long or short-term storage periods, please take the following precautions: Save all data and programs you want to keep to disk. Store the Allegro in a cool location (<20°C, 68°F). Your data and programs are secure as long as they have been saved to disk, even if the batteries become discharged. The data storage disk is non-volatile. It does not depend on the battery to store the data for extended periods. Storing the Allegro for Less Than Two Months If you store the Allegro for less than two months, we recommend that you leave the NiMH battery pack in the Allegro and attach the AC power adapter to keep the batteries charged. Once the battery pack is fully charged, the Allegro switches to trickle charge mode. You can leave the Allegro in trickle charge mode continuously without damaging the batteries. The battery pack is fully charged when you are ready to use the Allegro. Allegro DOS Owner’s Manual
41
Page 42
Storing the Allegro for More Than Two Months If you store the Allegro for more than two months, remove the battery pack and attach the AC power adapter to prevent the internal lithium backup battery from draining. When you are ready to use the Allegro, insert a battery pack and fully charge it if necessary. NiMH Battery Pack’s Useful Life Battery packs can be recharged approximately 600 times before they need to be replaced. This is dependent on the temperatures they have been exposed to, operating conditions, and charging and discharging practices. Recycling the NiMH Batteries The NiMH batteries inside the Allegro battery packs are recyclable. We are voluntarily participating in an industry program to collect and recycle these batteries when they are taken out of service in the United States and Canada. The recycling program provides a convenient alternative to placing used NiMH batteries into the trash or the municipal waste system. Our involvement in this program is part of our commitment to preserving our environment and conserving our natural resources. Contact our technical service to return spent batteries for recycling. Spare NiMH Battery Packs Fully charge spare battery packs before storing and store them in a cool location. Avoid placing battery packs “contact side” down on a metal surface. Also, do not stack packs so that their contacts touch one another. These practices cause the batteries to drain. The shelflife of a battery pack is about two months. Before using a spare pack, you should charge it.
▲ Short-Term Backup Supply The Allegro has a super capacitor that behaves like a backup battery. When the main batteries are removed, the capacitor maintains the RAM for up to five minutes, allowing you plenty of time to change the batteries. The capacitor cannot operate the Allegro. The capacitor is charged by the batteries. It holds a charge as long as the batteries or external power are supplied. When a battery pack is replaced, the capacitor charges up to full capacity in about two minutes.
42
Allegro DOS Owner’s Manual
Page 43
If power is not supplied to the Allegro for more than five minutes, the Allegro reboots when the battery pack is replaced or charged. All the programs, data, and applications saved to the disk are safe. Information that was not saved to the disk is lost. The super capacitor should not need replacement through the life of the Allegro.
▲ Backup Battery, Real Time Clock A 3.6 V lithium backup battery supplies current to the Allegro to maintain the real time clock when power is not supplied to the Allegro. This battery should last for at least five years. Replacing the Lithium Backup Battery If the Allegro does not hold the date and time or you get a CMOS error message, the lithium battery needs to be replaced. You can check and see whether or not the lithium battery is good or bad. Go to System Setup Program|System Information Screen to view the status of the lithium battery. You must return your Allegro to the factory for lithium backup battery replacement.
Allegro DOS Owner’s Manual
43
Page 44
Communication Ports The Allegro DOS has two 9 pin serial ports (located on the top of the case).
These ports are recessed to protect them in case of a drop. They are also completely sealed.
▲ 9 Pin Serial Communication Ports The standard 9 pin serial communication ports (COM1 and COM2) allow for the simultaneous operation of two serial devices such as printers, modems, and bar code wands. Additional power is provided on COM1 to power bar code wands and other sensors. The data transfer rate on these ports ranges from 300 baud to 115 Kbaud. Rubber connector protectors keep dirt and moisture out of the ports. The ports are sealed without the protectors. Be sure to use the serial communication cable (9 pin to 9 pin) included with the Allegro to connect the Allegro to a desktop PC. A wiring diagram of the cable is shown in Chapter 5, Technical Reference. Note that a standard ‘straight through’ serial cable does not work. 9 Pin D Connector Pinouts Pin # 1 Data Carrier Detect (DCD) Input 2 Receive Data (RCD) Input 3 Transmit Data (TXD) Output 4 Data Terminal Ready (DTR) Output 5 Ground (GND) 6 Data Set Ready (DSR) Input 7 Request To Send (RTS) Output 8 Clear To Send (CTS) Input 9 Ring Indicator (RI) Input Connecting Sensors to COM1 Pin 4 (DTR) on COM1 supplies up to 200 mA at +5 volts to power bar code scanners and other sensors. This signal (DTR) must be set high by the application to take advantage of this feature. When the DTR signal goes low, the output is -5 volts. Insure that the device connected to the DTR line can accept negative voltages or is protected against them (standard RS-232 signal levels). 44
Allegro DOS Owner’s Manual
Page 45
PC Card Slot The Allegro has a user-accessible PC Card Slot (PCMCIA 2.0 Type II) that allows you to add mass data storage and I/O capabilities to your Allegro. The PC card drivers and utilities are factory-installed on the Allegro. These programs provide the card and socket services necessary to operate the card. In DOS, the PC card is the D: drive.
▲ Types of PC Cards Accepted The PC card slot accepts Type I or Type II cards. These cards include ATA Flash cards, SRAM (Static Random Access Memory), Compact Flash cards, or Input/Output cards. All types have a 68 pin connector for attachment to the Allegro. The cards must be 5 V or 5 V/3 V (PC cards that are 3 V only are not supported). The PC card slot is a 16 bit card slot. It is not a “card bus” slot. Memory Cards A memory card is a solid state, self-contained memory board housed in a credit card-sized package. There are several types and brands of cards on the market. These cards behave like hard disks. Refer to Chapter 3, Program and Data Storage Options, for more details. Input/Output Device Cards Input/Output Device cards can provide additional communication capabilities to your Allegro. Common I/O cards include fax/modem and network cards. Refer to the manufacturer’s instructions for information on how to use these cards and for information about hardware or software accessories that may be required. Contact our sales department for information on compatible cards and technical information about the installation and operation of the cards. ▲ Inserting and Changing Cards 1) ATA cards should be ready to use. If you are using an SRAM card, make sure the battery is installed (if required) and that the card has been formatted. 2) Turn the Allegro off and place it face-down on a clean surface. 3) The card slot is located in the top part of the Allegro behind the display. It is accessed from behind through the PC card slot door. There are two screws holding the door in place. Turn each screw counter-clockwise l/4 of a turn to release the door.
Allegro DOS Owner’s Manual
45
Page 46
4) PC cards have a 68 pin socket on one end. Insert the card socketfirst. The front of the card should be facing the door.
❖ Important Note: Be careful when inserting and removing cards. Excess force could damage the card and the card drive. If the LED indicator for the PC card slot (farthest right) is blinking, the computer is writing to the card. Do not turn off the Allegro and remove the card until the LED stops blinking. Incomplete files can corrupt the data already stored on the card. 5) To remove a card, push the eject button, grasp the card firmly, and pull it out. 6) Close the door to the PC card slot. Turn both screws clockwise l/4 of a turn to seal the compartment.
▲ Displaying Information About the PC Card You can display information about the installed PC card such as the card type and the name of the manufacturer. Use the CARDINFO utility. From the DOS prompt type: CARDINFO and press ENTER. The following information is displayed: Slot 1: [Card Information] Card Type = ATA Disk (Drive D:) Manufacturer = Vendor Name Product Name = Vendor Product Name
46
Allegro DOS Owner’s Manual
Page 47
Sound Generator The Allegro has the ability to produce basic computer sounds such as beeps and clicks. The key press and screen tap sounds are generated by a secondary processor to reduce power consumption. The sound properties for key presses and screen taps can be adjusted in the System Setup Program|Keyboard|Display Screen. Note that the tone of key presses and screen taps can be adjusted, but the volume cannot.
Allegro DOS Owner’s Manual
47
Page 48
Expansion Pods Custom expansion pods allow you to integrate additional components as they become available. Options include an RF network, animal ID reader, bar code scanner, GPS receiver (shown below), parallel port, and analog sensor input. Call our Sales Department for information about the availability of these expansion pods. Expansion pods replace the PC card door. The Allegro remains sealed when an expansion pod is installed.
48
Allegro DOS Owner’s Manual