The text of a manual · part 13 of 15
PcOS Series 60 Multi-Station Slip Printers Programmer's Guide, pages 121 to 130
Pages 121 to 130 of 150
The original document is the PDF (1.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Ithaca PcOS Series 60
Page 121
Diagnostics
Level 1
PcOS Series 60
Ithaca Peripherals Incorporated
Programmer's Guide
Journal Test To run a journal test power on the printer while holding down the "SELECT" key. The select light will start to blink and the unit will be in Diagnostics select mode. If the "JOURNAL" key is pressed the unit will start a journal test. If the "Alarm" light starts to flash, the error indicated is the same as normal operation. The Interpreting Error Codes section of this document gives a list of normal alarm codes. The journal test will continue until the journal paper is exhausted or the test is stopped with the select key. To stop the test at any time press and hold the "SELECT" key until the printer stops. The test can be "Paused" by pressing and holding the "SLIP" key. The "JOURNAL" key will then feed journal paper one line for each press. To resume the test, press the "SLIP" key again or the "SELECT" key to stop the test. If the RECEIPT key is pressed while the unit is printing, the print test pattern will be changed from a walking character test to a I/H/+/- test. This test is used to adjust the printer.
Receipt Test To run a receipt test power on the printer while holding down the "SELECT" key. The select light will start to blink and the unit will be in Diagnostics select mode. If the "RECEIPT" key is pressed the unit will start a receipt test. If the "Alarm" light starts to flash, the error indicated is the same as normal operation. The Interpreting Error Codes section of this document gives a list of normal alarm codes. The Receipt test will print a test receipt and wait for the receipt to be removed from the printer. The printer will then print another test receipt. Test receipts will continue to be printed until the receipt paper is exhausted or the test is stopped with the select key. To stop the test at any time, press and hold the "SELECT" key until the printer stops. When the test is stopped the last receipt will be cut and ejected. If the RECEIPT key is pressed while the unit is printing, the print test pattern will be changed from a walking character test to a I/H/+/- test. This test is used to adjust the printer.
Slip Test, Sensor Calibration, and Vertical Alignment To run a slip test, power on the printer while holding down the "SELECT" key. The select light will start to blink and the unit will be in diagnostics select mode. If the "SLIP" key is pressed the unit will enter slip test. The slip test will start by turning out both the "Select" and "Alarm" lights. This is a sensor test mode. As a slip is inserted the "Alarm" light will light indicating that the front sensor has detected the slip. When the rear sensor detects the slip the "Select" light will be turned on. The sensor test mode will also allow both slip and the journal paper sensors to be calibrated. By pressing the "JOURNAL" key in the sensor test mode, the printer will adjust the threshold levels used to identify presence of paper. To run this test all printer covers must be installed, the slip table must be clear, and if the printer has a journal, it must be properly loaded with paper. When the "JOURNAL" key is pressed both the ALARM and SELECT lights will flash once. If either light stays on; either one of the sensors is bad or has degraded, or there is some type of obstruction. If this occurs (and there is no obstruction) press the "SELECT" key and a degraded mode default threshold will be used, this may keep the printer operational until the sensor can be replaced.
Page 120
Rev C 7/8/2008
Page 122
Programmer's Guide
PcOS Series 60
Ithaca Peripherals Incorporated
Diagnostics Level 1
The sensor test mode also allows adjustment of the vertical print alignment.. By pressing the "RECEIPT" key in the sensor test mode, the slip clamp will clamp on a slip and enter adjustment mode. Pressing the "SLIP" will print an adjustment pattern and the current adjustment. The "JOURNAL" key will decrease the adjustment and the "RECEIPT" key will increase the adjustment. The "SELECT" key will exit this mode and return to sensor test. At any time when both front and back sensors, sense the slip, the slip printing test can be started by pressing the "SLIP" key. The slip will then be printed until the front sensor no longer senses the slip. The printing will then pause while the slip is fed forward until the rear sensor no longer senses the slip. At this time an end of slip message will be printed and the slip released. The test can be "Paused" by pressing and holding the "JOURNAL" key. The "SLIP" key will then feed paper one line for each press. To resume the test press the "JOURNAL" key again. Press and hold the "SELECT" key to stop the test. If the RECEIPT key is pressed while the unit is printing the print test pattern will be changed from a walking character test to a I/H/+/- test. This test is used to adjust the printer.
Rev C 7/8/2008
Page 121
Page 123
Diagnostics
PcOS Series 60
Configuration
Ithaca Peripherals Incorporated
Programmer's Guide
Configuration Initial Power ON The initial power cycle of a Series 60 diagnostics will find that the EEPROM is not valid. This will be indicated by the "Select" and "Alarm" lights blinking. The "Alarm" light will blink twice as fast as the "Select" light. This must be corrected by reinitializing the EEPROM with default values. To initialize the EEPROM with default settings press the SLIP and RECEIPT keys when the error code is being indicated. This will set the unit description to a general description and configure a basic unit feature list. (NOTE: This Feature list may not match the true feature list) The configuration is as follows: • Parallel Port Active • Serial Port Inactive • Baud, 8 Bit, No parity • Slip Station Active • Journal Inactive • Receipt Inactive This default configuration can be altered in two ways. The first is by using the Local configuration mode. The second is by using the Remote Configuration Program, CFG6040. To use the Remote Configuration program see the remote configuration section below and the CFG60 Users Guide.
Manual Configuration The Series 60 can change its own configuration by pressing the "SELECT" and "SLIP" keys at power up or when it is in diagnostics mode. When these keys are released the unit will enter one of two modes. If the unit is configured with a journal the journal will be used for configuration display. If no journal is available the slip station will be used. If the journal station is used the current configuration will be printed. If the Slip station is used a slip must be inserted. To insert a slip place a sheet of paper on the slip table that is at least 4 inches wide. Slide the paper as far to the right as possible. When the slip is in position both the select and error lights will be lit. Because the slip will be printed in reverse it is of advantage to place the paper as far in the unit as possible. When the slip is in position press the "SLIP" key and the current configuration will be printed. When the configuration is printed the paper will be fed forward enough to allow the configuration to be read. The configuration mode is now ready to accept configuration changes. Each key and combination of keys will alter a configuration value. The keys will alter values as follows: "SLIP"
Serial or Parallel This key will toggle between serial and parallel communications mode
"RECEIPT"
Serial Mode
This key will cycle through the Serial mode options as follows:
40There are several configuration fields that can only be set by the fields are not required for proper printer operation.
Page 122
Rev C 7/8/2008 remote configuration program. These
Page 124
Programmer's Guide
PcOS Series 60
Ithaca Peripherals Incorporated
Diagnostics Configuration
8 bit No Parity 7 bit Even Parity 7 bit Odd Parity 7 bit No Parity41 8 bit Even Parity 8 bit Odd Parity "JOURNAL" Baud Rate This key will cycle through the baud rates available as follows: 19200, 9600, 4800, 2400, 1200, 600, 300 "SLIP + RECEIPT" Flow Control This key toggles between XON/XOFF and Ready/Busy (DTR) flow control. "JOURNAL + RECEIPT" Feature Select These keys select the available features by cycling through the available configurations as follows: Slip Station only Slip and Journal Stations Slip and Receipt Stations Slip, Journal, and Receipt Stations Any other combination will exit the mode if called from diagnostics or restart the mode if requested at power up. If the unit is turned off during configuration, what ever configuration was last displayed will be saved in EEPROM. The device description field can not be programmed from this mode. There is no way to enter alphanumeric data. If this field is to be changed the remote configuration program CFG60 must be used.
Enable Remote Configuration Remote configuration mode is a setup mode that allows a remote host to setup, display configuration information and test a series 60 printer.. This mode is designed to be operated by the CFG60 program running on a PC. To enable remote configuration connect a PC through COM1 or COM2 to the Serial port on the Series 60 printer. (The internal printer configuration is not used in remote configuration to determine the port used for the configuration process. The serial port is always used.) Load the configuration program into the PC. Power on the Printer and hold the "JOURNAL" and "RECEIPT" keys during power up. After both the Select and Alarm lights go out. Refer to the CFG60 Users Guide for CFG60 operation. It the printer is to be tested by CFG60 the parallel port should also be connected to the PC through LPT1 or LPT2. (The parallel port is not required for configuration) For more information on Remote Configuration see the CFG60 sections of this manual.
417 bit "No Parity" is not a true 7 bit mode.
It is a 7 bit, don't care about parity. The parity bit must be present but is ignored by the printer. The host must be configured for 7 bit 2 stop bits.
Rev C 7/8/2008
Page 123
Page 125
Diagnostics Flow Chart
Page 126
Programmer's Guide
PcOS Series 60
Character Sets
Ithaca Peripherals Incorporated
Diagnostics Mode
Set I
Chart 1
Start by powering on the printer with the SELECT key held down.
Self Diagnostics
The SELECT light will blink
JOURNAL Key Pressed
Yes
Start Journal Test
Chart 2
No
RECEIPT Key Pressed
Yes
Start Receipt Test
Chart 3
No
SLIP Key Pressed
YES
Start Slip Tests & Adjustments
Chart 4
No
SLIP & SELECT Keys Pressed
YES
Alter the Configuration
Chart 8
No
SLIP & RECEIPT Keys Pressed
YES
Debug Communications HEX DUMP
Chart 9
No
JOURNAL & RECEIPT Keys Pressed
YES
Remote Configuration Mode
No
Rev A 7/8/2008
Page cxxv
Page 127
Character Sets
PcOS Series 60
Set I
Ithaca Peripherals Incorporated
Programmer's Guide
Journal Test Mode
Chart 2
From Chart 1
Journal Test Mode
Print Configuration and Rev. Information
Print Test Pattern
RECEIPT Key
Yes
Change Test Pattern
SLIP Key
Yes
PAUSE
No
Return to Main Loop
Yes
No
SELECT Key
SLIP Key
No
Yes
Chart 1
Page cxxvi
Rev C 7/8/2008
Page 128
Programmer's Guide
PcOS Series 60
Ithaca Peripherals Incorporated
Character Sets Set I
Receipt Test Mode Receipt Test Mode
Chart 3
From Chart 1
Print Configuration and Rev. Information
Print Test Pattern
At End of Receipt?
Yes
Cut Receipt
No
RECEIPT Key Yes
Yes
Change Test Pattern
Yes
PAUSE
Receipt Removed? No No
SLIP Key Select Key
No No
Yes
Return to Main Loop
Yes
Select Key
SLIP Key
No
Yes
No
To Chart 1
Rev A 7/8/2008
Page cxxvii
Page 129
Character Sets Set I
PcOS Series 60
Ithaca Peripherals Incorporated
SLIP Test And Adjustment Slip Test & Adjustment Mode
Front Sensor
Programmer's Guide Chart 4
From Chart 1
YES
Alarm Lignt ON
YES
SELECT Lignt ON
YES
Adjust Sensors
Alarm Lignt OFF
Rear Sensor
SELECT Lignt OFF
JOURNAL Key
Chart 6
RECEIPT Key
YES
Adjust Alignment Chart 7
RECEIPT Key
YES
Print Slip Test Chart 5
SELECT Key
Page cxxviii
YES
Rev C 7/8/2008
Return to Main Menu
To Chart 1
Page 130
Programmer's Guide
PcOS Series 60
Character Sets
Ithaca Peripherals Incorporated
Slip Test Mode Slip Test Mode
Set I
Chart 5
From Pag4
Slip In Position
No
Return to Main Menu
To Chart 1
Yes
Print Configuration and Rev. Information
Print Test Pattern
Yes
Feed Slip Out
No
Front Sensor Clear? No
RECEIPT Key
Rear Sensor Clear?
Yes
Change Test Pattern
No
Yes
Print "End of Test Slip"
JOURNAL Key
Yes
PAUSE
No
Return to Main Menu To Chart 1
Yes
SELECT Key
JOURNAL Key
Yes
Yes
Rev A 7/8/2008
No
Page cxxix