Page 221

Demo Software

A

Keyboard Demo The Keyboard Demo allows the user to try out each key. This allows a user to get the feel of the keyboard, and become used to the effects of the key on both the status line and the characters produced by the keystrokes. A display containing the names of all the keys is presented, and the names can be deleted by pressing the appropriate key. This rule is changed for F3 - the first time it is pressed, its label changes from soft-3 to EXIT. If it is pressed again, the test terminates and control returns to the Keyboard and Display Demo Menu.

×

Note: This demonstrates how labels on the screen can be changed when conditions change - either the label can be removed, indicating that the function isn’t available, or the actual label and the function a key performs can be changed. status bar 7:50 PM status bar Press key to erase. A B C D E F G H I J K L M N O P Q R S T U V W X Y Z - . ‘ 0 1 2 3 4 5 6 7 8 9 <enter> <bs> <sp> soft-1 soft-2 soft-3 F1 F2 F3

Scan Demo The scan demo is operated by activating the scanner (using the <enter> key) and attempting to scan bar coded data. The code set for successful scans is reported along with the scanned data. Pressing F3 returns control to the Feature Demo menu. This scan demo has the BEEP_GOOD and BUZZ_BAD options set. status bar 7:50 PM Scanning Demo

ENTER to scan

EXIT F3

If the data is scannable, the scanned data, its code set, and a message regarding the code set’s acceptability are displayed. If the scan fails, lines 2, 3 and 4 are replaced with a BAD READ message. In either case, another code can be scanned by pressing ENTER.

A-9

Page 222

TRAKKER T2090 Hand-Held Batch Computer User's Manual status bar 7:50 PM Scanning Demo

ENTER to scan (scanned data) or Bad Read Codeset of data Reject/accept msg EXIT F3

System Setup Note: This section of the program illustrates a number of approaches to menu systems. Some combination of effects may be useful in your programs. The System Setup screen is reached via the F3 key on the Main menu It has six sub options and two possible exits. The exits are on the last row of the menu: •

Main Menu (Back to the Initial Menu)

•

Exit (to DOS).

The sub options are:

A-10

•

Misc Set

Miscellaneous Settings

•

Spkr Demo

Speaker demonstration

•

Mem Stat

Status of the T2090 Memory and disk

•

Pwr Mgmt

Power Management

•

Poll Setup

Selection of content of the TO-HOST.BAT file

•

Char Set

A display of the character set native to the LCD

Page 223

Demo Software

A

They are arranged in two columns as follows: status bar 7:50 PM System Setup Menu Misc Set Pwr Mgmt Spkr Demo Poll Setup Mem Stat Char Set Main Menu <<EXIT>> -->> F1

Next F2

Prev F3

A cursor is placed beneath the current option (Misc Set on initial entry). The Function keys move the cursor, and the ENTER key is used as an EXECUTE key. F1 changes the current column and the direction of the arrow over it (the -->> becomes <<--) to indicate that a press will change the position and the indicator back to the other column. F2 moves down within the column one entry at a time, stepping to the next column when the end of a column is reached. F3 moves up one entry in a similar fashion. No other keys are active. Since the Function keys do not auto-repeat, reaching the EXIT requires at least four keystrokes in this menu design.

Miscellaneous Settings This screen is for miscellaneous Settings. There are four settings: Clock, Clock Format, Key Click and display contrast. Keys and their actions for MISC. Settings Screen: status bar 7:50 PM MISC. Settings 1.Clock Settings 2.Clock Format 3.Key Click <<<CONTRAST>>> BACK LIGHTER DARKER F1 F2 F3

•

1 enters “Clock Settings” screen

•

2 toggles the clock format between 24hr and AM/PM modes. (Due to space considerations, the AM/PM mode does not have a seconds display). The current mode is reflected in the status bar, as well as the Clock Setting menu.

•

3 is used to turn Key Click on and off.

•

F1 “BACK” key returns to the main menu

•

F2 “LIGHTER” lightens the display contrast

A-11

Page 224

TRAKKER T2090 Hand-Held Batch Computer User's Manual

•

F3 “DARKER” darkens the display contrast

Note: The current state of Key Click cannot be detected by application programs. The default state for Key Click is OFF. For this reason, the first time Key Click is selected in a given instance of the menu, Key Click is turned ON and a label is displayed to this effect. The second time, Key Click is turned OFF and the message is changed to reflect this. Since Key Click has to be ON to be turned OFF, turning it OFF causes a click (Actually a tone) while turning it on doesn’t. The Set Clock Screen has seven entry fields, month, day, year, hour, minutes, seconds and am / pm. (Exception: If the time format is 24 hour, the AM/PM field is not displayed, and therefore cannot be entered.) Entering new data in a field overwrites the previous data and when the field is full, it automatically tabs to the next field, and wraps up to the first field. If illegal data has been entered, and error message is displayed and the cursor is placed on the first illegal field. Keys and their actions for Set Clock Screen: status bar 7:50 PM Set Clock Date: 10/15/1997 Time: 10:09:00 am

ABORT F1

A-12

NEXT F2

ACCEPT F3

•

1 - 0 for all fields except am / pm, where only ‘A’ and ‘P’ are legal.

•

F1 “ABORT” key returns to the main menu without saving new values

•

F2 “NEXT” key tabs to the next field.

•

F3 “ACCEPT” or ‘ENTER’ keys sets new values then returns to the main menu

Page 225

Demo Software

A

Speaker Demonstration The speaker demonstration shows the variety of sounds that can be easily generated by the speaker. The Function keys are used to select a sound, which is then played by pressing the ENTER key. The selection <EXIT> is not a sound, but is actually the way back to the System Setup Menu. This screen is arranged in three columns as follows. status bar 7:50 PM Speaker Demo Beep Buzz Pipe Fog Clicks Siren Cuckoo 2500 4000 1500 3000 4500 2000 3500 <EXIT> -->> Next Prev F1 F2 F3

Note: On this menu, the alphanumeric keypad has also been enabled to drive the cursor around and execute selections. Both the alphabetic and numeric values of a given key have the same effect. This allows the Autorepeat function of the keypad to be used to speed up selection. The following keyboard illustration show the uses of the keys. Only the tinted keys are used for this example. Other possibilities include using 7, 9, 1, and 3 as ‘go to the corner’ keys.

A7B

E9 F

8 key is UP (same as Prev key).

C8D G4H

K6 B

Q3 R

W’ X

SP Y .Z

These keys are inactive. These keys are inactive.

U0V BS

1 and 3 keys are inactive. 2 key is Down (same as Next key).

O2P S-T

4 key is Left , 6 is Right. 5 key is Execute (same as ENTER key).

I5J M1 N

7 and 9 keys are not used.

These keys are inactive. These keys are inactive.

A-13

Page 226

TRAKKER T2090 Hand-Held Batch Computer User's Manual

Memory Status The Memory status screen shows the total Ram, Disk, and available disk space in Kilobytes. The EXIT key returns to the Main Menu. Available Disk space will vary, depending on how big the data file DEMODATA.DAT is and whether previously polled data has been retained. (See the section on HOST software.) Space remaining is also changed by the presence of other software and data files. status bar

7:50 PM

Memory Status Total Ram: xxxK Total Disk: xxxxK Free Disk: xxxxxK EXIT

Power Management This screen allows setting of the Power Management timeouts. The values are graphically illustrated by ‘slider’ bars, which are adjusted on the selected field through the Less and More keys. The Next key allows selection of different values to change, as well as selecting the Sys Menu selection, which returns control to the System Menu. When Sys Menu is selected, the Less and More labels become Abort and Save. One of these keys must be pressed to exit. When a timer value gets to 0, the message Never is displayed in place of the value indicator and slider bar. Also, the Less label is suppressed. When a value reaches its maximum, the More label is suppressed. Note that the first 7 values for Doze are 1/8 seconds, and move the slider bar much less than subsequent steps. status bar 7:50 PM Power Management Doze 1s❚❚❚ Backlite 1m❚ Auto-off Never Sys Menu Less F1

A-14

More F2

Next F3

Page 227

Demo Software

A

On this menu, the alphanumeric keypad has also been enabled to drive the cursor around and adjust selections. Both the alphabetic and numeric values of a given key have the same effect. This allows the Autorepeat function of the keypad to be used to speed up selection and adjusting of values. The keypad does not have the ability to select an option for exit to the System Setup Menu, however. The Abort/Save choice must be made using the function keys. This helps to avoid accidental selections of the wrong values. The following keyboard illustration shows the uses of the keys. Only the tinted keys are used for this example.

A7B

E9F C8D

G4H

K6B I5J

M1 N

Q3R

1 and 3 keys are inactive. 2 key is Down (same as Next key).

W’X

These keys are inactive. These keys are inactive.

SP

These keys are inactive. These keys are inactive.

O2P S-T U0V BS

7 and 9 keys are not used. 8 key is UP. (No Function key does this. It is an advantage of using the keypad.) 4 key is Less , 6 is More. This key is inactive.

Y .Z

Poll Setup This allows setting the TO-HOST.BAT file to have the effect of Polling or Not Polling when docking is detected. The screen is as follows: The demo can be set to be Polled for the collected data or Not Polled. (P)olled or (N)ot? [P,N]?

This must be answered with a P or N keystroke. Doing the setup for this takes several seconds, but eventually control is returned to the System Setup Menu. Note: This is done by doing a system() call for the batch file SWAP.BAT. Changing the content of the batch file allows (almost) anything to be done. For example, SWAP.BAT

A-15

Page 228

TRAKKER T2090 Hand-Held Batch Computer User's Manual does a CLS, which causes the status line to be erased. It does not re-appear until the System Setup Menu is re-entered. Several useful batch file tools are installed on the A: drive for your convenience.

Host Polling of Data The Demo has the ability to communicate in a rudimentary fashion with a host PC. This is accomplished by running the file server utility on the host. This utility is located in the Intermec\Tools\FileServer folder after the installation. Start it from your start menu by selecting “Intermec File Copy” from the Intermec programs Group. Once started, on the page selected with the Communications Options tab, select your communications port and the filename to send the file to on the host. The append/overwrite radio buttons are meaningless on the page, as any file copied up using XMODEM will replace other files of the same name. On the Serial Port Setup page, set the baud rate to 9600 and press the Run button. The server is now set to receive a file any time a T2090 is dropped into a dock. After the file has been received, it can be imported into a spreadsheet for manipulation, or processed by some other program. The records in the file are arranged as follows: •

All of the record is a single line of ASCII, terminated with a <CR><LF> pair

•

Each field of the file is wrapped in double quotes

•

The fields are separated by commas

•

The fields are Name, Date (ccyy/mm/dd hh:mm:ss ), a data entry (Just the data portion of the scan, or the manual entry) and source (MANUAL or SCAN).

Transmission will be attempted by the T2090 when docking is first detected if there is a file to transmit and the T2090 has been configured for Polling (see the section on the System Setup). Notes:

A-16

•

The polling is controlled on the T2090 by the batch file TO-HOST.BAT. The described actions expect that you haven’t changed this file. Should you wish to change it, keep your messages to a single line to avoid scrolling whichever screen is current on the T2090 when it is docked. The utility GOTO1-1.COM is supplied to direct the cursor to the upper left corner of the screen between steps of you r batch file.

•

The actions on the file after polling are controlled by the batch file on the T2090. This is named POSTXMIT.BAT.

Page 229

Demo Software

A

The following files may be copied to POSTXMIT.BAT depending on the desired post transmit action. POSTXMIT.DEL - deletes the data file. POSTXMIT.SAV - save the data file in LASTDATA.DAT, destroying any existing LASTDATA.DAT file in the process. POSTXMIT.APP - actually does nothing, so the T2090 appends to the existing data file the next time data is collected. By default, POSTXMIT.BAT leaves the file for more data to be appended. Files are transferred via XMODEM protocol. A program on the PC can substitute for File Server when configured to receive a file with XMODEM at 9600 baud.

Character Set This displays the various characters available through the ROM on the LCD display. The characters are displayed 32 to the page across 8 pages. Use any key to advance a page (the Function keys go two pages). The first 16 characters are used as buffers, and aren’t consistent. There is a hole in the character set entries 80h through 9Fh always display as blanks. 20h through 7Dh conform to ASCII. (The ~ and DEL characters 7Eh and 7Fh are displayed as Right and Left pointing arrows.) This is the second of 8 screens. 20: 28:( 30:0 38:8 21:! 29:) 31:1 39:9 22:” 2a:* 32:2 3a:: 23:# 2b:+ 33:3 3b:; 24:$ 2c:, 34:4 3c:< 25:% 2d:- 35:5 3d:= 26:& 2e:. 36:6 3e:> 27:’ 2f:/ 37:7 3f:?

Note: This character set does not match the standard DOS code page 850. For help, contact Intermec Technical Support.

A-17

Page 230