Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 21 of 25

TRAKKER T2090 Batch Hand-Held Computer User's Manual, pages 201 to 210

Pages 201 to 210 of 246

The original document is the PDF (737 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec T2090

Page 201

BIOS Support

7

FWTSETUP.EXE Pressing the F1 key during reset will cause invocation of a setup batch file from which the Setup executable will be run. Operational Note: Invocation of FWTSETUP.EXE will occur in the AUTOEXEC.BAT via a new system variable FWT. Therefore, the developer should be aware of this default environment variable and not use the same name. FWT=ON denotes F1 key was pressed.

Boot Diagnostics During the Boot process, a number of pieces of information pass the screen. Some are revision identifiers for particular software components, and others are diagnostic checkpoints. These checkpoints are B-0......9 and appear sequentially during the booting of DOS. Should you experience difficulties, take note of the revisions and the last diagnostic number to appear.

First DOS Boot Initial run will utilize the default CONFIG.SYS file located on the ROMDISK drive A. This CONFIG.SYS will attempt to locate a user drive (C) CONFIG.SYS and run it, causing a nonfatal warning to occur. The default AUTOEXEC.BAT file located on ROMDISK will then run, testing the existence of a root directory on drive C, if this does not exist, drive C will be formatted, FWTSETUP.EXE will be run, a user CONFIG.SYS file and an AUTOEXEC.BAT file are created on drive C. The initial Path of A:\;C:\ will be set, the current drive changed to C and the newly created AUTOEXEC.BAT run. This will leave the operator at the C:\ prompt with path access to the runtime programs resident on drive A (transfer and remote disk).

Drive C Initialization During the very first boot cycle, or whenever the user’s C drive is corrupted or unformatted, the following screen will appear immediately following the ‘5’ diagnostic during boot. This screen and procedure allow the developer an opportunity to format the C drive. C: drive not found! 1. Format C: 2. Do NOT format

Choose option:

Select 1 or 2 according to the operator preference, no ENTER key is required.

7-15

Page 202

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

The T2090 will begin formatting immediately upon completion of the boot cycle to DOS if 1 is selected. You will be prompted for format confirmation and must respond with either Y or N.

Warm DOS Boot Once the unit has booted to DOS once, all subsequent boots, will run both the resident CONFIG.SYS (ROMDISK) and user CONFIG.SYS (FLASHDISK), and the resident and user AUTOEXEC.BAT files. This allows application developer flexibility in configuration and boot control for the application.

Forcing a COLD Boot Force a COLD boot condition by pressing the left corner of the BS (backspace) key, the right corner of the SP (space) key and the I/O (power) key simultaneously. The RTC (real time clock) will default to a 1-1-92 date, enter the setup routine and reset the time and date. Forcing a cold boot will also reset all the power management and screen characteristics to the factory defaults.

Flash Update Utility This update program reprograms the lower 448K of the TRAKKER flash without damaging the existing drive C. The program reads only the lower 448K from the target flash file located on the PC, even though that file is 2MB in size. To run the flash update utility: 1. Place the FLASH UPDATE UTILITY diskette in drive A. 2. Extract the update utility files by running A:\FLSH_UP.EXE from within Windows to a path of your choice. Selecting the root directory will create a \FLSH_UP subdirectory with all of the necessary update program files. 3. Place FLASH IMAGE MASTER diskette in drive A. 4. Extract the target image file to the same directory (that is, \FLSH_UP) as the update utilities by running A:\SW300108.EXE from within Windows (the filename, SW300108.EXE, will change with later versions). 5. Important: reboot the PC to DOS. The update utilities create virtual drives and do not run reliably within Windows, particularly Windows 95. 6. Run UPDATE.EXE (see syntax below) using the /F switch to specify the exact image filename. Specify the appropriate COM port and use 38400 baud rate. 115K may not be reliable with certain versions of DOS on the host PC.

7-16

Page 203

BIOS Support

7

UPDATE PROGRAM SYNTAX: update [/Ffilename ] [/COM# ] [/Bbaud] where: filename is your image file # is a COM port number (default=1, such as COM1) baud is a valid baud rate (9600, 19200, 38400 . . . or 115) (default baud rate=115) The following screen appears: FLASH UPDATER PROGRAM copyright 1998, Intermec Technologies Corp. 1) Reboot the T2090 and enter Setup by hitting F1 during boot 2) Enter Setup password (default 123) and select LOAD FILE 3) Set the correct Baud and select START LOAD Remote Drive = G:

Local Drive = C:

Remote Disk v6.22 (Revision 2.50.11) (XT) Copyright © 1989-1997 Datalight, Inc. Installed as Drive G: /COM1 /B38400+ /T10 Waiting for drive, Put T2090 in cradle! If unit wasn’t in remote mode, then there may be a delay Hit a key to Terminate Looking for Drive G:

. . . . .

7. On the T2090, enter setup by first turning the unit off and then depressing the F1 key immediately upon power up. If the real-time clock has not been set, you will be asked to set the time. Press F3 to accept the default. The clock will be reset after the load. The setup program may also be entered by typing FWTSETUP. 8. Once in setup, enter the password (default=123) and select LOAD FILE. Set the Baud Rate to 38400 and select Start Load RT. 9. Replace the T2090 in its cradle. The PC will automatically detect the T2090 in remote mode and begin sending files. Once the PC changes screen and is in SERVER mode, then select BACK and QUIT on the T2090. This causes the unit to reboot.

7-17

Page 204

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

10. Leave the unit in the cradle until all further operations are automatically completed. 11. At the end of the process, the unit reboots automatically. Leave the unit in the cradle until all further operations are automatically completed. Certain versions of software may not reboot automatically. Reboot manually by simultaneously pressing BS, SP, and keys.

L

7-18

Page 205

8 Hardware Specifications

Page 206

This page is a scan with no text; see it in the PDF.

Page 207

Hardware Specifications

8

This chapter provides specific information about the TRAKKER T2090 equipment, including mechanical, electrical, and environmental specifications for the T2090 and EZ Dock Docking System.

TRAKKER T2090 Specifications The following tables provide hardware specifications for the TRAKKER T2090.

Mechanical Specifications Item

Description

Case Material

High impact thermoplastic, tamper resistant case design non-slip surfaces sealed for dust and moisture

Color

Intermec blue or Intermec gray

Dimensions

3.16” W x 7.38” L x 1.68” H

Ergonomics

Designed for true one-hand operation, either hand, with or without gloves

Weight

10 oz. (including batteries)

Display

8 line by 20 character, temperature compensated, Film Supertwist LCD with user enabled backlight operation

Keypad

Unique 13 key alphanumeric, 3 function keys, tactile and audio feedback

Connectors

Contact RS-485 / RS-232 port and charging

Visual Indicators

Power ON/OFF, Low Battery and GOOD/BAD scanner READ

Audio Indicator

Keyclick - User enabled /disabled using Int 16h

Electrical Specifications Item

Description

External Power

8vDC @450mA (charging requirement)

Internal Power

Rechargeable NiMH, 2.4v @ 1,200 mAh

Battery Capacity

10-20 hours typical usage including 600 bar code scans

Recharging Time

Less than 4 hours in approved docking station

Power Management:

5 advanced states: On, Doze, Sleep, Suspend, and Off

8-3

Page 208

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

Environmental Specifications Item

Description

Operating temperature

-4° to +122° F ( -20° to +50° C )

Storage temperature

-4° to +158° F ( -20° to +70° C )

Humidity

5 to 95 percent

Drop / Shock

Survives multiple, four-foot drops to concrete

Vibration

5-50 Hz @ 1 Grms, 50-300 Hz @ 0.5 Grms

Bar Code Scanner Specifications Item

Description

Operation

Keyboard trigger for TRUE one hand operation for either hand

Indicator

Displayed on LCD screen and a GOOD/BAD scanner READ LED, with or without audio

Emission Class

CDRH Class II

Emission Duration

Greater than 0.25 seconds

Emission Limit

Less than 0.001 W

Scan Range

1 to 36 inches

Symbologies

Standard width modulated bar codes

Processing Specifications

8-4

Item

Description

Microprocessor

NEC V30, 32 MHz

Flash ROM

2 MB for DOS, BIOS and Flash File, upgradable to 4 MB

RAM

2 MB

Real Time Clock

Internal, 1 second resolution

Operating System

DOS 6.22 compatible

Page 209

Hardware Specifications

8

EZ Dock Specifications The following tables provide specifications for the EZ Dock Docking System.

Power Module Mechanical Specifications Item

Description

Case Material

High impact thermoplastic

Color

Intermec blue or Intermec gray

Dimensions

5.40” W x 5.40” L x 5.70” H

Weight

19.5 oz.

Connectors

(2) RJ45 connectors for data Power in is a mini Molex Contact RS-232/485 port and charging

Visual Indicators

Power ON/OFF on front

2-Slot Cradle Mechanical Specifications Item

Description

Case Material

High impact thermoplastic

Color

Intermec blue or Intermec gray

Dimensions

4.00” W x 5.40” L x 5.70” H

Weight

13.0 oz.

Contacts

Contact RS-232/485 port and charging

Docking System Environmental Specifications Item

Description

Operating temperature

-4° to +122° F ( -20° to +50° C )

Storage temperature

-4° to +158° F ( -20° to +70° C

Ambient temperature

32° to +104° F ( 0° to +40° C )

Humidity

5 to 95 percent

Vibration

5-50 Hz @ 1 Grms, 50-300 Hz @ 0.5 Grms

8-5

Page 210

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

RS-232 and RS-485 Communications Configurations Serial communications can be configured for either RS-232 or RS-485 protocols. On the 2-slot cradle, there are two resident RJ45 connectors, which are used to make hardwire connections to host systems and other peripheral equipment. For single-cradle configurations, two types of connections can be made: dedicated mode or multidrop. •

In multidrop mode, the user would communicate with both hand-held units at the same time whether RS-232 or RS-485 by connecting a single COM cable to the innermost RJ45 connector.

•

For dedicated configurations the user can communicate to each of the two hand-helds individually by connecting two cables and by activating a small switch located on the inside panel of the 2-slot cradle. This will separate the signals for the two-cradle positions.

The switch is in the UP position for multidrop communications and DOWN for dedicated configurations. The dedicated option is not configurable for multi-cradle applications.

Pin

RS-232 Signal

Description

RS-485 Signal

1

N/C

No Connect

N/C

2

N/C

No Connect

N/C

3

GND

Ground

GND

4

RxD

Serial Data

Data -

5

TxD

Serial Data

Data +

6

VIN

Power IN

VIN

7

N/C

No Connect

N/C

8

N/C

No Connect

N/C

These signals are transmitted through the power module and 2-slot cradle assemblies from the RJ45 connectors positioned in the unit.

8-6