Page 121

im_xm_receive_file

4 im_xm_receive_file Purpose

This function receives a file through the serial communications port using XMODEM protocol.

Syntax

#include "imt209x.h" IM_STATUS far im_xm_receive_file (IM_CHAR far *file_name IM_COM_PORT port_id) ;

IN Parameters port_id

Identifies the communications port. Use this constant:

IM_COM1 COM1 selected. OUT Parameters

Return Value file_name Identifies the file to be received by the TRAKKER T2090 computer. This function returns one of these codes: IM_SUCCESS Success. IM_INVALID_PORT The value for port_id is invalid. The parameter must be set to IM_COM1 for the T2090 computer. IM_PARSER_ERROR A parsing error occurred when receiving the file.

Notes

See Also

The host must be set up to send a file (using XMODEM protocol) to the T2090 computer for this function to execute successfully. Otherwise, this function returns IM_PARSER_ERROR to indicate a communications error. For help, see “Transferring Data” in Chapter 1. im_xm_transmit_file

4-61

Page 122

im_xm_transmit_file im_xm_transmit_file Purpose

This function transmits a file through the serial communications port using XMODEM protocol.

Syntax

#include "imt209x.h" IM_STATUS im_xm_transmit_file (IM_CHAR far *file_name, IM_COM_PORT port_id) ;

IN Parameters file_name Identifies the file to be transmitted from the TRAKKER T2090 computer. port_id

Identifies the communications port. Use this constant:

IM_COM1 COM1 selected. OUT Parameters Return Value

None. This function returns one of these codes: IM_SUCCESS Success. IM_INVALID_PORT The value for port_id is invalid. The parameter must be set to IM_COM1 for the T2090 computer. IM_PARSER_ERROR A parsing error occurred when sending the file.

Notes

4-62

The host must be set up to receive a file (using XMODEM protocol) from the T2090 computer for this function to execute successfully. Otherwise, this function returns IM_PARSER_ERROR to indicate a communications error. For help, see “Transferring Data” in Chapter 1.

Page 123

im_xm1k_receive_file

4 im_xm1k_receive_file Purpose

This function receives a file through the serial communications port using XMODEM-1K protocol.

Syntax

#include "imt209x.h" IM_STATUS far im_xm1k_receive_file (IM_CHAR far *file_name, IM_COM_PORT port_id) ;

IN Parameters port_id

Identifies the communications port. Use this constant:

IM_COM1 COM1 selected. OUT Parameters

Return Value file_name Identifies the file to be received by the TRAKKER T2090 computer. This function returns one of these codes: IM_SUCCESS Success. IM_INVALID_PORT The value for port_id is invalid. The parameter must be set to IM_COM1 for the T2090 computer. IM_PARSER_ERROR A parsing error occurred when receiving the file.

Notes

See Also

The host must be set up to send a file (using XMODEM-1K protocol) to the T2090 computer for this function to execute successfully. Otherwise, this function returns IM_PARSER_ERROR to indicate a communications error. For help, see “Transferring Data” in Chapter 1. im_xm1k_transmit_file

4-63

Page 124

im_xm1k_transmit_file im_xm1k_transmit_file Purpose

This function transmits a file through the serial communications port using XMODEM-1K protocol.

Syntax

#include "imt209x.h" IM_STATUS im_xm1k_transmit_file (IM_CHAR far *file_name, IM_COM_PORT port_id) ;

IN Parameters file_name Identifies the file to be transmitted from the TRAKKER T2090 computer. port_id

Identifies the communications port. Use this constant:

IM_COM1 COM1 selected. OUT Parameters Return Value

None. This function returns one of these codes: IM_SUCCESS Success. IM_INVALID_PORT The value for port_id is invalid. The parameter must be set to IM_COM1 for the T2090 computer. IM_PARSER_ERROR A parsing error occurred when sending the file.

Notes

See Also

4-64

The host must be set up to receive a file (using XMODEM-1K protocol) from the T2090 computer for this function to execute successfully. Otherwise, this function returns IM_PARSER_ERROR to indicate a communications error. For help, see “Transferring Data” in Chapter 1. im_xm1k_receive_file

Page 125

im_ym_receive_file

4 im_ym_receive_file Purpose

This function receives a file through the serial communications port using YMODEM protocol.

Syntax

#include "imt209x.h" IM_STATUS far im_ym_receive_file (IM_CHAR far *file_name, IM_COM_PORT port_id) ;

IN Parameters port_id

Identifies the communications port. Use this constant:

IM_COM1 COM1 selected. OUT Parameters

Return Value file_name Identifies the file to be received by the TRAKKER T2090 computer. This function returns one of these codes: IM_SUCCESS Success. IM_INVALID_PORT The value for port_id is invalid. The parameter must be set to IM_COM1 for the T2090 computer. IM_PARSER_ERROR A parsing error occurred when receiving the file.

Notes

See Also

The host must be set up to send a file (using YMODEM protocol) to the T2090 computer for this function to execute successfully. Otherwise, this function returns IM_PARSER_ERROR to indicate a communications error. For help, see “Transferring Data” in Chapter 1. im_xm_transmit_file

4-65

Page 126

im_ym_transmit_file im_ym_transmit_file Purpose

This function transmits a file through the serial communications port using YMODEM protocol.

Syntax

#include "imt209x.h" IM_STATUS im_ym_transmit_file (IM_CHAR far *file_name, IM_COM_PORT port_id) ;

IN Parameters file_name Identifies the file to be transmitted from the TRAKKER T2090 computer. port_id

Identifies the communications port. Use this constant:

IM_COM1 COM1 selected. OUT Parameters Return Value

None. This function returns one of these codes: IM_SUCCESS Success. IM_INVALID_PORT The value for port_id is invalid. The parameter must be set to IM_COM1 for the T2090 computer. IM_PARSER_ERROR A parsing error occurred when sending the file.

Notes

See Also

4-66

The host must be set up to receive a file (using YMODEM protocol) from the T2090 computer for this function to execute successfully. Otherwise, this function returns IM_PARSER_ERROR to indicate a communications error. For help, see “Transferring Data” in Chapter 1. im_ym_receive_file

Page 127

5 Reader Command Reference

Page 128

This page is a scan with no text; see it in the PDF.

Page 129

1XJJ Co d e 39 Reader Command Reference

5

This chapter describes the reader commands that you can use while operating the computer. Reader commands, such as Backlight On, allow you to perform a task on the computer.

Using Reader Commands A reader command causes the computer to perform a task. Some reader commands temporarily override the configuration settings and some actually change the configuration settings. For example, you can turn the backlight on to easily view the T2090 computer screen when you are working in a dimly lit environment. You can execute reader commands by • scanning a command from a Code 39 bar code label.

• sending a command from a device through the serial port.

• passing the command string from an application using the im_command function.

There are three general types of reader commands: •

Accumulate mode commands

•

Operating commands

•

File management commands

The reader commands are listed in alphabetical order within these three categories. You will find the purpose, command syntax, and bar code labels for each reader command in this chapter. Note: The Code 39 bar code labels in this chapter show an asterisk (*) at the beginning and end of the human-readable interpretation to represent the start and stop codes. If you are creating your own Code 39 bar code labels, your bar code printing utility may automatically supply the asterisks as the start/stop code.

Using Accumulate Mode You can use Accumulate mode to collect data from a series of bar code labels and enter them as a single label. When you put the computer in Accumulate mode, the computer will collect all scanned bar code labels in the computer’s buffer until you scan either the Enter or Exit Accumulate mode command. As you accumulate the data from bar code labels, the data is visible on the bottom line of the screen. You can edit the accumulated data with the Backspace and Clear commands.

5-3

Page 130

TRAKKER T2090 Hand-Held Batch Computer User’s Manual

1XJJ Co d e 39

Backspace This command deletes the last character from the current data record you are accumulating. Clear

This command deletes the entire data record you are accumulating.

Note: If you are not in Accumulate mode, the Backspace and Clear commands have no effect and you will hear an error beep. When you exit Accumulate mode, the accumulated data is “entered” as a data record. Up to 250 characters can be held in the buffer. If the data record count exceeds 250 characters, the data is truncated. If you reset the computer (software or hardware reset), you exit Accumulate mode, the entire buffer is cleared, and all data accumulated is lost. To use Accumulate mode The syntax to use the Enter Accumulate command is: +/data where: +/ is the syntax for the Enter Accumulate mode command. data is the optional data you want to enter. Data can be a reader command that is executed when you exit Accumulate mode.

1. Scan this bar code label to Enter Accumulate mode: Enter Accumulate Mode

*+/* *+/*

2. Scan the bar code label(s) for the data you want to enter. You can scan labels from the “Full ASCII Charts” in Appendix C. For example, scan this label to change the computer’s configuration and set the preamble to the characters ABC. Change Configuration / Set Preamble to ABC

*$+ADABC* *$+ADABC*

Or, to edit the accumulated data, scan one of these bar code labels: Backspace

Clear

*-+*

*--*

*-+*

5-4

*- -*