Page 47
Command 4 Configuration Reference
Use this chapter to learn about the configuration commands supported on the SR61T. This chapter contains these topics: •
Using Configuration Commands
•
Configuration Commands By Function
•
SR61T Configuration Commands
35
Page 48
Chapter 4, Configuration Command Reference
Using Configuration Commands A configuration command changes the way the SR61T operates. For example, you can change the Beep Volume and make the SR61T beeper very quietly. You can configure the SR61T: • by sending commands to your SR61T from your PC using EasySet.
• by sending commands to a bar code setup sheet. Then, scan the bar codes onscreen with your SR61T (SR61TE or SR61TA only), or print the setup sheet and scan the bar codes.
• by sending commands to your SR61T from your Intermec computer using Intermec Settings. Note: When you first connect to an Intermec computer, only SR61T settings common to the Intermec computer’s internal scanner settings are changed to the internal scanner’s default settings.
For a list of all the commands and their default values as they are organized in EasySet, see the next section, “Configuration Commands By Function.” For descriptions of each command organized alphabetically, see “SR61T Configuration Commands” on page 40.
Configuration Commands By Function The configuration commands are grouped by function and reflect the organization of the Commands window in EasySet. Reset All Parameters
36
Command
Default Value
See Page
Administrator reset factory defaults
N/A
40
SR61T Tethered Scanner User’s Guide
Page 49
Chapter 4, Configuration Command Reference
Interface Settings RS-232 Parameter
Default Value
See Page
Baud rate
57600
41
Data bits
8
46
Parity
None
52
Stop bits
1
54
Hardware/software protocol timeout
1000 ms
49
Configurable RS-232 Protocol
Not active
45
ENQ
Not active
47
ACK
Not active
40
NAK
Not active
51
LRC
Not active
50
Inter-character delay
None
49
Inter-message delay
None
50
PS/2 Keyboard Wedge
Default Value
See Page
Keyboard selection
North America
50
Override caps lock key
Not active
51
Data Transmission Settings Data Transmission Command
Default Value
See Page
ISCP activation
Active
50
Data format
Raw
46
Transmission frame size (TFS)
4096
56
ISCP
Not active
47
Symbology identifier
Event notification
Not transmitting
55
Preamble
None
53
Postamble
<CR><LF>
52
Data editing
N/A
46
Alt Mode
Not active
41
Control character conversion
Active
45
SR61T Tethered Scanner User’s Guide
37
Page 50
Chapter 4, Configuration Command Reference
Symbology Settings Symbology
Default Value
See Page
Disable all symbologies
N/A
46
Australian Post
Not active
41
Aztec
Not active
41
BPO
Not active
42
Canada Post
Not active
42
Codabar
Not active
43
Codablock Codablock A
Not active
43
Codablock F
Not active
43
Code 11
Not active
44
Code 39
Active
44
Not active
54
Code 93/93i
Special keys interpretation
Not active
44
Code 128/GS1-128
Active
44
ISBT 128
Not active
45
GTIN processing
Not active
45
DataMatrix
Active
46
Dutch Post
Not active
46
EAN/UPC
Active
47
ISBN
Not active
47
GTIN processing
Not active
47
Not active
48
GS1 DataBar Omni-directional
Not active
49
GS1 Expanded
Not active
49
GS1 Limited
Not active
49
Interleaved 2 of 5
Not active
50
Japan Post
Not active
50
Matrix 2 of 5
Not active
50
Maxicode
Not active
51
Micro PDF417
Not active
51
MSI
Not active
51
GS1 Composite GS1 DataBar
38
SR61T Tethered Scanner User’s Guide
Page 51
Chapter 4, Configuration Command Reference
Symbology Settings (continued) Symbology
Default Value
See Page
PDF417 active
52
Planet
Not active
52
Postnet
Not active
53
QR Code
Not active
53
Standard 2 of 5
Not active
54
Telepen
Not active
55
TLC 39
Not active
56
Operating Settings Trigger Activation Command
Default Value
See Page
Trigger mode
Level
57
Trigger timeout
2 seconds
57
Turn off after good read
Active
58
Data Decoding Security Command
Default Value
See Page
Predefined security levels
Normal
53
Consecutive same read data validation
Auto read count before transmission
45
Timeout between identical consecutive codes
300 ms
56
Timeout between different consecutive codes
None
55
Center Decoding Command
Default Value
See Page
Center decoding activation
Not active
43
Center decoding tolerance
No tolerance
43
Beeps/LED Command
Default Value
See Page
Beep and LED Mode
SR61T default mode
41
Beep volume
High
42
SR61T Tethered Scanner User’s Guide
39
Page 52
Chapter 4, Configuration Command Reference Beeps/LED Command
Default Value
See Page
Beep frequency
2610 Hz
42
Good read beeps Number Duration Timing
1 80 ms Before transmission
48 48 48
Good read LED duration
2000 ms
48
Error beep
On
47
Setup beep
On
54
Beeps/LED Command
Default Value
See Page
2D symbologies Stacked code crackle
On
54
Vibrate alert Vibrate alert Duration
Off 300 ms
58 58
Sensor optimization
Automatic
53
Operating Settings (continued)
SR61T Configuration Commands This section lists the configuration commands in alphabetical order and provides a description of each command. To configure your SR61T using these commands, see www.intermec.com/EasySet.
ACK A feature of the Configurable RS-232 Protocol. The scanner waits for the length of the hw/sw timeout period of time to receive an ACK message from the host and then time out. If the scanner times out then the scanner issues error beeps.
Administrator Reset Factory Defaults Causes the SR61T to perform a restart and restores all configuration commands to their default settings.
40
SR61T Tethered Scanner User’s Guide
Page 53
Chapter 4, Configuration Command Reference
Alt Mode A data transmission settings that allow the SR61T to transmit special characters to a host computer. For example, if Alt mode is enabled, the character “Alt+ 0196” is interpreted as “Ä.” When Alt mode is disabled, “Alt+0196” is transmitted as is.
Australian Post SR61TA (area imager) and SR61TE (near-far range area imager) only. Enables or disables decoding of Australian Post symbology. Australian Post is a 4-state bar code that allows Australian Post to sort incoming mail using a bar code. There are three types of bar codes corresponding to FCC values 11, 59, and 62. BarDIMM only needs the DPID and Customer information, and automatically generates all the other information like the FCC or Reed-Solomon checksum.
Aztec SR61TA (area imager) and SR61TE (near-far range area imager) only. Enables or disables decoding of Aztec symbology. Aztec is a 2D matrix symbology made up of square modules on a square grid, with a square bulls eye pattern at their center. Aztec Code symbols can encode large amounts of data with user-defined error-correction level.
Baud Rate Sets the baud rate for the communications. The baud rate must match the baud rate of the host. You can set Baud Rate to a value of 1200, 2400, 9600, 19200, 38400, 57600, or 115200.
Beep and LED Mode Sets the way in which the beeps and LED lights will behave on the SR61T. By default, the scanner is set to behave in one way, but it can be configured to operate differently.
Beep Duration Sets the length of the beeps. You can set Beep Duration to a value from 0 to 2550 ms. When Beep Duration is set to 0 ms, the beeper is off. SR61T Tethered Scanner User’s Guide
41
Page 54
Chapter 4, Configuration Command Reference
Use Beep Duration in combination with Beep Frequency and Beep Volume to define beeps according to operator preference and work environment.
Beep Frequency Sets the frequency, or pitch, of the beeps. You can set Beep Frequency to a value from 1000 to 5110 Hz. Use Beep Frequency in combination with Beep Volume and Good Read Beep Duration to define beeps according to operator preference and work environment.
Beep Volume Adjusts the volume of the beeps. You can set Beep Volume to Low, Medium, or High. Note: To turn off the beeper, set the Beep Duration to 0.
Use Beep Volume in combination with Beep Frequency and Good Read Beep Duration to define beeps according to operator preference and work environment.
BPO SR61TA (area imager) and SR61TE (near-far range area imager) only. Enables or disables decoding of BPO (British Post Office) 4-state bar code symbology. BPO was developed by the British Post office for encoding European postcode data similar to the way the U.S. Postnet symbology is used for encoding Zip Code data. BPO provides European countries with a simple and efficient postal bar coding scheme.
Canada Post SR61TA (area imager) and SR61TE (near-far range area imager) only. Enables or disables decoding of Canada Post 4-state bar code symbology. Canada Post contains addressing as well as customerspecific information. Canada Post sends mail pieces through Canada Post’s integrated distribution system in the most cost-efficient way. 42
SR61T Tethered Scanner User’s Guide