Page 47

Command 4 Configuration Reference

Use this chapter to learn about the configuration commands supported on the SR61T. This chapter contains these topics: •

Using Configuration Commands

•

Configuration Commands By Function

•

SR61T Configuration Commands

35

Page 48

Chapter 4, Configuration Command Reference

Using Configuration Commands A configuration command changes the way the SR61T operates. For example, you can change the Beep Volume and make the SR61T beeper very quietly. You can configure the SR61T: • by sending commands to your SR61T from your PC using EasySet.

• by sending commands to a bar code setup sheet. Then, scan the bar codes onscreen with your SR61T (SR61TE or SR61TA only), or print the setup sheet and scan the bar codes.

• by sending commands to your SR61T from your Intermec computer using Intermec Settings. Note: When you first connect to an Intermec computer, only SR61T settings common to the Intermec computer’s internal scanner settings are changed to the internal scanner’s default settings.

For a list of all the commands and their default values as they are organized in EasySet, see the next section, “Configuration Commands By Function.” For descriptions of each command organized alphabetically, see “SR61T Configuration Commands” on page 40.

Configuration Commands By Function The configuration commands are grouped by function and reflect the organization of the Commands window in EasySet. Reset All Parameters

36

Command

Default Value

See Page

Administrator reset factory defaults

N/A

40

SR61T Tethered Scanner User’s Guide

Page 49

Chapter 4, Configuration Command Reference

Interface Settings RS-232 Parameter

Default Value

See Page

Baud rate

57600

41

Data bits

8

46

Parity

None

52

Stop bits

1

54

Hardware/software protocol timeout

1000 ms

49

Configurable RS-232 Protocol

Not active

45

ENQ

Not active

47

ACK

Not active

40

NAK

Not active

51

LRC

Not active

50

Inter-character delay

None

49

Inter-message delay

None

50

PS/2 Keyboard Wedge

Default Value

See Page

Keyboard selection

North America

50

Override caps lock key

Not active

51

Data Transmission Settings Data Transmission Command

Default Value

See Page

ISCP activation

Active

50

Data format

Raw

46

Transmission frame size (TFS)

4096

56

ISCP

Not active

47

Symbology identifier

Event notification

Not transmitting

55

Preamble

None

53

Postamble

<CR><LF>

52

Data editing

N/A

46

Alt Mode

Not active

41

Control character conversion

Active

45

SR61T Tethered Scanner User’s Guide

37

Page 50

Chapter 4, Configuration Command Reference

Symbology Settings Symbology

Default Value

See Page

Disable all symbologies

N/A

46

Australian Post

Not active

41

Aztec

Not active

41

BPO

Not active

42

Canada Post

Not active

42

Codabar

Not active

43

Codablock Codablock A

Not active

43

Codablock F

Not active

43

Code 11

Not active

44

Code 39

Active

44

Not active

54

Code 93/93i

Special keys interpretation

Not active

44

Code 128/GS1-128

Active

44

ISBT 128

Not active

45

GTIN processing

Not active

45

DataMatrix

Active

46

Dutch Post

Not active

46

EAN/UPC

Active

47

ISBN

Not active

47

GTIN processing

Not active

47

Not active

48

GS1 DataBar Omni-directional

Not active

49

GS1 Expanded

Not active

49

GS1 Limited

Not active

49

Interleaved 2 of 5

Not active

50

Japan Post

Not active

50

Matrix 2 of 5

Not active

50

Maxicode

Not active

51

Micro PDF417

Not active

51

MSI

Not active

51

GS1 Composite GS1 DataBar

38

SR61T Tethered Scanner User’s Guide

Page 51

Chapter 4, Configuration Command Reference

Symbology Settings (continued) Symbology

Default Value

See Page

PDF417 active

52

Planet

Not active

52

Postnet

Not active

53

QR Code

Not active

53

Standard 2 of 5

Not active

54

Telepen

Not active

55

TLC 39

Not active

56

Operating Settings Trigger Activation Command

Default Value

See Page

Trigger mode

Level

57

Trigger timeout

2 seconds

57

Turn off after good read

Active

58

Data Decoding Security Command

Default Value

See Page

Predefined security levels

Normal

53

Consecutive same read data validation

Auto read count before transmission

45

Timeout between identical consecutive codes

300 ms

56

Timeout between different consecutive codes

None

55

Center Decoding Command

Default Value

See Page

Center decoding activation

Not active

43

Center decoding tolerance

No tolerance

43

Beeps/LED Command

Default Value

See Page

Beep and LED Mode

SR61T default mode

41

Beep volume

High

42

SR61T Tethered Scanner User’s Guide

39

Page 52

Chapter 4, Configuration Command Reference Beeps/LED Command

Default Value

See Page

Beep frequency

2610 Hz

42

Good read beeps Number Duration Timing

1 80 ms Before transmission

48 48 48

Good read LED duration

2000 ms

48

Error beep

On

47

Setup beep

On

54

Beeps/LED Command

Default Value

See Page

2D symbologies Stacked code crackle

On

54

Vibrate alert Vibrate alert Duration

Off 300 ms

58 58

Sensor optimization

Automatic

53

Operating Settings (continued)

SR61T Configuration Commands This section lists the configuration commands in alphabetical order and provides a description of each command. To configure your SR61T using these commands, see www.intermec.com/EasySet.

ACK A feature of the Configurable RS-232 Protocol. The scanner waits for the length of the hw/sw timeout period of time to receive an ACK message from the host and then time out. If the scanner times out then the scanner issues error beeps.

Administrator Reset Factory Defaults Causes the SR61T to perform a restart and restores all configuration commands to their default settings.

40

SR61T Tethered Scanner User’s Guide

Page 53

Chapter 4, Configuration Command Reference

Alt Mode A data transmission settings that allow the SR61T to transmit special characters to a host computer. For example, if Alt mode is enabled, the character “Alt+ 0196” is interpreted as “Ä.” When Alt mode is disabled, “Alt+0196” is transmitted as is.

Australian Post SR61TA (area imager) and SR61TE (near-far range area imager) only. Enables or disables decoding of Australian Post symbology. Australian Post is a 4-state bar code that allows Australian Post to sort incoming mail using a bar code. There are three types of bar codes corresponding to FCC values 11, 59, and 62. BarDIMM only needs the DPID and Customer information, and automatically generates all the other information like the FCC or Reed-Solomon checksum.

Aztec SR61TA (area imager) and SR61TE (near-far range area imager) only. Enables or disables decoding of Aztec symbology. Aztec is a 2D matrix symbology made up of square modules on a square grid, with a square bulls eye pattern at their center. Aztec Code symbols can encode large amounts of data with user-defined error-correction level.

Baud Rate Sets the baud rate for the communications. The baud rate must match the baud rate of the host. You can set Baud Rate to a value of 1200, 2400, 9600, 19200, 38400, 57600, or 115200.

Beep and LED Mode Sets the way in which the beeps and LED lights will behave on the SR61T. By default, the scanner is set to behave in one way, but it can be configured to operate differently.

Beep Duration Sets the length of the beeps. You can set Beep Duration to a value from 0 to 2550 ms. When Beep Duration is set to 0 ms, the beeper is off. SR61T Tethered Scanner User’s Guide

41

Page 54

Chapter 4, Configuration Command Reference

Use Beep Duration in combination with Beep Frequency and Beep Volume to define beeps according to operator preference and work environment.

Beep Frequency Sets the frequency, or pitch, of the beeps. You can set Beep Frequency to a value from 1000 to 5110 Hz. Use Beep Frequency in combination with Beep Volume and Good Read Beep Duration to define beeps according to operator preference and work environment.

Beep Volume Adjusts the volume of the beeps. You can set Beep Volume to Low, Medium, or High. Note: To turn off the beeper, set the Beep Duration to 0.

Use Beep Volume in combination with Beep Frequency and Good Read Beep Duration to define beeps according to operator preference and work environment.

BPO SR61TA (area imager) and SR61TE (near-far range area imager) only. Enables or disables decoding of BPO (British Post Office) 4-state bar code symbology. BPO was developed by the British Post office for encoding European postcode data similar to the way the U.S. Postnet symbology is used for encoding Zip Code data. BPO provides European countries with a simple and efficient postal bar coding scheme.

Canada Post SR61TA (area imager) and SR61TE (near-far range area imager) only. Enables or disables decoding of Canada Post 4-state bar code symbology. Canada Post contains addressing as well as customerspecific information. Canada Post sends mail pieces through Canada Post’s integrated distribution system in the most cost-efficient way. 42

SR61T Tethered Scanner User’s Guide