Page 21
and Configuring the 2 Connecting SR61T
Use this chapter to understand how to connect the SR61T to a host and configure the SR61T. This chapter covers these topics: •
Connecting Your SR61T to a Host Computer
•
Setting Parameters in the SR61T
9
Page 22
Chapter 2, Connecting and Configuring the SR61T
Connecting Your SR61T to a Host Computer To connect your SR61T to a host computer, you need the appropriate accessory cable. For a list and description of each cable, see “Cable Accessories” on page 71.
Creating a USB Connection The USB cable you choose depends on whether your host PC provides power through the USB port. If your host PC provides power through the USB port, connect using a standard USB cable. If your host PC does not provide power through the USB port, connect using a powered USB cable. To connect with a standard USB cable 1 Make sure you have the standard USB cable (PN 236-182-xxx). 2 Connect the standard USB cable to your SR61T.
3 Connect the USB cable to the host PC. 4 If necessary, configure your SR61T for an International keyboard. The default keyboard is North America. For help, see “International Keyboard Parameters” on page 17. To connect with a powered USB cable 1 Make sure you have the powered USB cable (PN 236-183-xxx). 2 Connect the powered USB cable to the SR61T and a power supply (P/N 851-089-105). Plug the power supply to an AC power outlet.
10
SR61T Tethered Scanner User’s Guide
Page 23
Chapter 2, Connecting and Configuring the SR61T
3 Connect the USB cable to the host PC. 4 If necessary, configure your SR61T for an International keyboard. The default keyboard is North America. For help, see “International Keyboard Parameters” on page 17.
Creating an RS-232 Connection The RS-232 cable you choose depends on whether your host PC provides power through the RS-232 port. If your host PC provides power through the RS-232 port, connect using the standard RS-232 cable. If your host PC does not provide power through the RS-232 port, connect using the powered RS-232 cable. To connect with a standard RS-232 cable 1 Make sure you have the standard RS-232 cable (P/N 236-184-xxx). 2 If you are connecting to an Intermec computer, turn it off. Otherwise, leave the host PC on.
SR61T Tethered Scanner User’s Guide
11
Page 24
Chapter 2, Connecting and Configuring the SR61T
3 Connect the standard RS-232 cable to your SR61T.
4 Connect to the host PC. 5 If you are connecting to an Intermec computer, turn it on. 6 If necessary, configure your SR61T serial parameters to match the PC. The default serial parameters for the SR61T are: Serial Parameter
Default Setting
Baud rate
57600
Data bits
8
Parity
None
Stop bits
1
For help, see “Serial Parameter Parameters” on page 20 or EasySet version 5.6.0.1 or later. EasySet is available from the Intermec web site at www.intermec.com/EasySet. To connect with a powered RS-232 cable 1 Make sure you have a powered RS-232 cable (P/N 236-185-xxx or P/N 236-198-xxx). 2 If you are connecting to an Intermec computer, turn it off. Otherwise, leave the host PC on. 3 Connect the externally powered RS-232 cable to the SR61T and a power supply. Plug the power supply into an AC power outlet. 12
SR61T Tethered Scanner User’s Guide
Page 25
Chapter 2, Connecting and Configuring the SR61T
4 Connect to the host PC. 5 If you are connecting to an Intermec computer, turn it on. Note: While the green light on the Intermec computer is flashing, do not disconnect the scanner from the Intermec computer. 6 If necessary, configure your SR61T serial parameters to match the PC. The default serial parameters for the SR61T are: Serial Parameter
Default Setting
Baud rate
57600
Data bits
8
Parity
None
Stop bits
1
For help, see “Serial Parameter Parameters” on page 20 or EasySet version 5.6.0.1 or later. EasySet is available from the Intermec web site at www.intermec.com/EasySet.
SR61T Tethered Scanner User’s Guide
13
Page 26
Chapter 2, Connecting and Configuring the SR61T
Creating a Keyboard Wedge Connection There are several different keyboard wedge cables available for your connection to a host PC. You can choose from a standard or an externally powered cable. To connect with a standard keyboard wedge cable 1 Turn off your host PC. 2 Make sure you have the appropriate cable. If you host PC does provide power, use a standard keyboard wedge cable (P/N 236186-xxx). 3 Connect the standard keyboard wedge cable to your SR61T and the host PC.
o
4 Turn on your host PC. 5 If necessary, configure your SR61T for an International keyboard by scanning bar codes. The default keyboard is North America. For help, see “International Keyboard Parameters” on page 17. To connect with a powered keyboard wedge cable 1 Turn off your host PC. 2 Make sure you have the appropriate cable. If your host PC does not provide power, use the powered keyboard wedge cable (P/N 236187-xxx). 3 Connect the powered keyboard wedge cable to your SR61T and a host a power supply (P/N 851-089-105). Plug the power supply into an AC power outlet.
14
SR61T Tethered Scanner User’s Guide
Page 27
Chapter 2, Connecting and Configuring the SR61T
4 Connect the keyboard wedge cable to the host PC. 5 Turn on your host PC. 6 If necessary, configure your SR61T for an International keyboard by scanning bar codes. The default keyboard is North America. For help, see “International Keyboard Parameters” on page 17. To connect the SR61T using a Y-cable 1 Turn off your host PC. 2 Connect the Y-cable (P/N 236-214-001) to your SR61T.
SR61T Tethered Scanner User’s Guide
15
Page 28
Chapter 2, Connecting and Configuring the SR61T
3 Connect one end of the Y-cable to your host PC and the other end to a PS2 keyboard.If your host PC does not provide enough power, connect the Y-cable to a power supply (P/N 851-089-005). Then plug the power supply to an AC power outlet. 4 Turn on your host computer. 5 If necessary, configure your SR61T for an International keyboard. The default keyboard is North America. For help, see “International Keyboard Parameters” on page 17.
Creating a Wand Emulation Connection You can create a wand emulation connection to an Intermec computer by connecting a wand emulation cable to the computer. There are several types of cables available for use. The type of cable you choose will depend on the Intermec computer you have. For a list of cables to choose from, see “Cable Accessories” on page 71. Note: You can connect the following Intermec computers using a wand emulation cable: 2420, 2425, 2435, 2455, 2475, 2480, 2481, 2485, 2486 To create a wand emulation connection 1 Make sure that you have the appropriate wand emulation cable. (P/N 236-188-xxx, P/N 236-189-xxx, or 236-190-xxx). 2 Connect the wand emulation cable to your SR61T and the Intermec computer. 3 (Optional) You can also configure the wand emulation cable to enable it to communicate differently with an Intermec computer. For help, see “Creating a Wand Emulation Connection” on page 16. Note: When you use a wand emulation connection, post processing features like postamble, preamble and data editing are not available. You must change these settings using your Intermec computer.
16
SR61T Tethered Scanner User’s Guide
Page 29
Chapter 2, Connecting and Configuring the SR61T
Note: If you get a good beep read from the SR61T but receive no data on your host computer, this means that the bar code you scanned is too large for your Intermec computer to process.
Setting Parameters in the SR61T After you connect your SR61T to a host, you may need to configure it to communicate properly with the host. Use this section to change the way that the SR61T transmits encoded data. This section contains the following bar codes: •
“International Keyboard Parameters” on page 17.
•
“Serial Parameter Parameters” on page 20.
To configure additional SR61T settings, see “Operating Settings” on page 74 or EasySet version 5.6.0.1 or later. EasySet is available from the Intermec web site at www.intermec.com/EasySet.
International Keyboard Parameters If your SR61T is connected to a host with a keyboard wedge cable, you may need to configure your SR61T to behave like an International keyboard. Scan the following bar codes to make your keyboard behave like the following keyboards. * = default North America* \60\02\53\20\00\00\00 Belgian French Windows \60\02\53\20\00\3A\40 Danish Windows \60\02\53\20\00\2D\20
SR61T Tethered Scanner User’s Guide
17