Page 47

B Default Settings

37

Page 48

Appendix B, Default Settings

Default Configuration Use the following tables to see the default values of the configuration commands supported on your SR30. The commands are grouped by function and reflect the organization of the Commands window in EasySet version 5.6.0.0 or later. For detailed command descriptions, see the EasySet online help. The latest version of EasySet is available at no charge from the Intermec web site at www.intermec.com. * = Symbologies and/or settings that are supported by the with area imager only.

Command

Default Value

Reset factory defaults except locked parameters

N/A

Interface Setting Commands Command

Default Value

RS-232 parameters Baud rate

19200

Data bits

8

Parity

None

Stop bits

1

Hardware/software protocols timeout 1000 ms ENQ

Not active (default 05h)

ACK

Not active (default 06h)

NAK

Not active (default 15h)

XON/XOFF software protocol

Not active

RTS/CTS hardware protocol

Not active

LRC (longitudinal redundancy check) Not active

38

SR30 Handheld Scanner User’s Guide

Page 49

Appendix B, Default Settings

Interface Setting Commands (continued) Command

Default Value

Inter-character delay

None

Inter-message delay

None

USB parameters USB cable mode

Keyboard HID

Keyboard selection

North America

Override caps lock key

Active

Keyboard wedge Keyboard selection

North America

Override caps lock key

Active

Data Transmission Commands Command

Default Value

Data transmission settings ISCP

Not Active

Data format

Raw

Transmission frame size (TFS)

2048

Event notification EasySet label

Active

Preprocessing ISCP bar code

Not active

Wake-up

Not active

Unsuccessful decoding

Not active

Start of read session

Not active

End of read session

Not active

Start-up

Not active

Trigger pulled

Not active

Trigger released

Not active

Symbology identifier

Not transmitted

Preamble Keyboard wedge

None

RS-232

None

SR30 Handheld Scanner User’s Guide

39

Page 50

Appendix B, Default Settings

Data Transmission Commands (continued) Command

Default Value

USB Keyboard HID

None

Generic HID

None

Postamble Keyboard wedge

Carriage Return + Line Feed

RS-232

Carriage Return + Line Feed

USB Keyboard HID

Carriage Return + Line Feed

Generic HID

Carriage Return + Line Feed

Data editing Active scenarios

N/A

Scenario 1

Not active

Scenario 2

Not active

Scenario 3

Not active

Scenario 4

Not active

Scenario 5

Not active

Scenario 6

Not active

Scenario 7

Not active

Symbology Setting Commands Command

Default Value

Disable all symbologies

N/A

Disable all extended reading ranges

N/A

Aztec*

Not active

Codabar

Not active

Codablock* Codablock A 40

Not active SR30 Handheld Scanner User’s Guide

Page 51

Appendix B, Default Settings

Symbology Setting Commands (continued) Command Codablock F

Default Value Not active

Code 11

Not active

Code 39

Active

Reading range

Extended

Reading tolerance

High

Code 93/Code 93i

Not active

Code 128/GS1-128

Active

Reading range

Extended

Reading tolerance

High

DataMatrix*

Active

EAN/UPC UPC-A

Active

UPC-E

Active

EAN-8

Active

EAN-13

Active

UPC-E1

Not active

GS1 Composite*

Not active

CC-A/B

Not active

CC-CC

Not active

GS1 DataBar (RSS) Omni-directional

Not active

Limited

Not active

Expanded

Not active

Interleaved 2 of 5

Not active

Reading range

Extended

Reading tolerance

High

Matrix 2 of 5

Not active

Maxi Code*

Not active

MicroPDF417*

Not active

MSI Code

Not active

PDF417*

Active

Plessey Code

Not active

SR30 Handheld Scanner User’s Guide

41

Page 52

Appendix B, Default Settings

Symbology Setting Commands (continued) Command

Default Value

QR Code*

Not active

Standard 2 of 5

Not active

Telepen

Not active

TLC 39

Not active

Operating Setting Commands Command

Default Value

Scanning/Triggering Triggering modes

Level

Trigger Timeout

2 sec

Hardware trigger

Active

Software trigger

Not active Start character <STX> (02h) Stop character <ETX> (03h)

Turn off after good read

Active

Aiming beam Activation

Off

Duration

0.5 sec

Data decoding security Predefined security levels

Normal

Consecutive same read data validation

Auto read count before transmission

Timeout between identical consecutive codes

300 ms

Timeout between different consecutive codes

None

Sensor optimization Lighting

LED brightness 100%

Center decoding* Activation 42

Not active SR30 Handheld Scanner User’s Guide

Page 53

Appendix B, Default Settings

Operating Setting Commands (continued) Command Tolerance

Default Value No tolerance

Beeps/green indicator LED Volume

High

Note (tone frequency)

High (2090 Hz)

Power-up beeps/Power-up LED

On

Good read beeps Number

1

Duration

80 ms

Timing

Before transmission

Good read LED duration

80 ms

Error beep

On

Setup beep

On

Bad read message

Not active Default=“NOREAD”

Note: The next table applies to area imagers only.

Imager Setting Commands Command

Default Value

Pre-defined imager settings 1D codes only

N/A

Standard 1D and 2D codes

N/A

1D and 2D codes, bright environment

N/A

1D and 2D codes with reflective surface

N/A

General Aimer flashing

Aimer flashing (optimized for decode)

Decode mode

2D imager

SR30 Handheld Scanner User’s Guide

43

Page 54

Appendix B, Default Settings

Imager Setting Commands (continued) Command

Default Value

Illumination level

Maximum 100%

Illumination mode

Illumination LEDs always on

Image data interface

RS-232

Image data transmission

Synchronous

Image flip

None

Image rotation

Sensor view (no rotation)

Initial 1D search area

Center

Lighting goal

42

Lighting mode

Illumination priority

Snapshot Snapshot compression

None

Snapshot resolution

Full resolution

Events Snapshot ready event

Not active

Video Select video start condition

N/A

Select video stop condition

N/A

Video on

N/A

Video off

N/A

Video compression

None

Video compression quality

No compression

Video resolution

Full resolution

Video decode mode

Not active

Events Video start event

Not active

Video stop event

Not active

Signature capture Scenario 1-4 Activation

44

Not active

SR30 Handheld Scanner User’s Guide

Page 55

Appendix B, Default Settings

Imager Setting Commands (continued) Command

Default Value

Capture area definition Automatic correction

Both horizontal and vertical

Image validation Focus check

Not active

Image ratio check

Not active

Image processing Projective mapping and resolution

Not active

Contrast enhancement

Disable

Noise reduction

No noise reduction

Edge enhancement

Disable

Image output Output format

Grayscale

Output compression

None

Output compression quality

50

Reset scenario

Configuration and Utility Commands Command

Default Value

Get firmware version

N/A

Get decode version

N/A

Get shutter speed

N/A

Get configuration signature

N/A

Get 1D filter sequence

N/A

Get filter list

N/A

Firmware upgrade with RS-232 cable

N/A

Host Interface Processor (HIP) firmware upgrade

N/A

Optical setup (using configuration bar codes)

Enable

SR30 Handheld Scanner User’s Guide

45

Page 56

Worldwide Headquarters 6001 36th Avenue West Everett, Washington 98203 U.S.A. tel 425.348.2600 fax 425.355.9551 www.intermec.com © 2008 Intermec Technologies Corporation. All rights reserved.

SR30 Handheld Scanner User’s Guide

*123-456-789* P/N 934-017-002