The text of a manual · part 7 of 7
SR30 Handheld Scanner User's Guide: Appendix B - Default Settings
Pages 47 to 56 of 56, from SR30 Handheld Scanner User's Guide
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec SR30
Page 47
B Default Settings
37
Page 48
Appendix B, Default Settings
Default Configuration Use the following tables to see the default values of the configuration commands supported on your SR30. The commands are grouped by function and reflect the organization of the Commands window in EasySet version 5.6.0.0 or later. For detailed command descriptions, see the EasySet online help. The latest version of EasySet is available at no charge from the Intermec web site at www.intermec.com. * = Symbologies and/or settings that are supported by the with area imager only.
Command
Default Value
Reset factory defaults except locked parameters
N/A
Interface Setting Commands Command
Default Value
RS-232 parameters Baud rate
19200
Data bits
8
Parity
None
Stop bits
1
Hardware/software protocols timeout 1000 ms ENQ
Not active (default 05h)
ACK
Not active (default 06h)
NAK
Not active (default 15h)
XON/XOFF software protocol
Not active
RTS/CTS hardware protocol
Not active
LRC (longitudinal redundancy check) Not active
38
SR30 Handheld Scanner User’s Guide
Page 49
Appendix B, Default Settings
Interface Setting Commands (continued) Command
Default Value
Inter-character delay
None
Inter-message delay
None
USB parameters USB cable mode
Keyboard HID
Keyboard selection
North America
Override caps lock key
Active
Keyboard wedge Keyboard selection
North America
Override caps lock key
Active
Data Transmission Commands Command
Default Value
Data transmission settings ISCP
Not Active
Data format
Raw
Transmission frame size (TFS)
2048
Event notification EasySet label
Active
Preprocessing ISCP bar code
Not active
Wake-up
Not active
Unsuccessful decoding
Not active
Start of read session
Not active
End of read session
Not active
Start-up
Not active
Trigger pulled
Not active
Trigger released
Not active
Symbology identifier
Not transmitted
Preamble Keyboard wedge
None
RS-232
None
SR30 Handheld Scanner User’s Guide
39
Page 50
Appendix B, Default Settings
Data Transmission Commands (continued) Command
Default Value
USB Keyboard HID
None
Generic HID
None
Postamble Keyboard wedge
Carriage Return + Line Feed
RS-232
Carriage Return + Line Feed
USB Keyboard HID
Carriage Return + Line Feed
Generic HID
Carriage Return + Line Feed
Data editing Active scenarios
N/A
Scenario 1
Not active
Scenario 2
Not active
Scenario 3
Not active
Scenario 4
Not active
Scenario 5
Not active
Scenario 6
Not active
Scenario 7
Not active
Symbology Setting Commands Command
Default Value
Disable all symbologies
N/A
Disable all extended reading ranges
N/A
Aztec*
Not active
Codabar
Not active
Codablock* Codablock A 40
Not active SR30 Handheld Scanner User’s Guide
Page 51
Appendix B, Default Settings
Symbology Setting Commands (continued) Command Codablock F
Default Value Not active
Code 11
Not active
Code 39
Active
Reading range
Extended
Reading tolerance
High
Code 93/Code 93i
Not active
Code 128/GS1-128
Active
Reading range
Extended
Reading tolerance
High
DataMatrix*
Active
EAN/UPC UPC-A
Active
UPC-E
Active
EAN-8
Active
EAN-13
Active
UPC-E1
Not active
GS1 Composite*
Not active
CC-A/B
Not active
CC-CC
Not active
GS1 DataBar (RSS) Omni-directional
Not active
Limited
Not active
Expanded
Not active
Interleaved 2 of 5
Not active
Reading range
Extended
Reading tolerance
High
Matrix 2 of 5
Not active
Maxi Code*
Not active
MicroPDF417*
Not active
MSI Code
Not active
PDF417*
Active
Plessey Code
Not active
SR30 Handheld Scanner User’s Guide
41
Page 52
Appendix B, Default Settings
Symbology Setting Commands (continued) Command
Default Value
QR Code*
Not active
Standard 2 of 5
Not active
Telepen
Not active
TLC 39
Not active
Operating Setting Commands Command
Default Value
Scanning/Triggering Triggering modes
Level
Trigger Timeout
2 sec
Hardware trigger
Active
Software trigger
Not active Start character <STX> (02h) Stop character <ETX> (03h)
Turn off after good read
Active
Aiming beam Activation
Off
Duration
0.5 sec
Data decoding security Predefined security levels
Normal
Consecutive same read data validation
Auto read count before transmission
Timeout between identical consecutive codes
300 ms
Timeout between different consecutive codes
None
Sensor optimization Lighting
LED brightness 100%
Center decoding* Activation 42
Not active SR30 Handheld Scanner User’s Guide
Page 53
Appendix B, Default Settings
Operating Setting Commands (continued) Command Tolerance
Default Value No tolerance
Beeps/green indicator LED Volume
High
Note (tone frequency)
High (2090 Hz)
Power-up beeps/Power-up LED
On
Good read beeps Number
1
Duration
80 ms
Timing
Before transmission
Good read LED duration
80 ms
Error beep
On
Setup beep
On
Bad read message
Not active Default=“NOREAD”
Note: The next table applies to area imagers only.
Imager Setting Commands Command
Default Value
Pre-defined imager settings 1D codes only
N/A
Standard 1D and 2D codes
N/A
1D and 2D codes, bright environment
N/A
1D and 2D codes with reflective surface
N/A
General Aimer flashing
Aimer flashing (optimized for decode)
Decode mode
2D imager
SR30 Handheld Scanner User’s Guide
43
Page 54
Appendix B, Default Settings
Imager Setting Commands (continued) Command
Default Value
Illumination level
Maximum 100%
Illumination mode
Illumination LEDs always on
Image data interface
RS-232
Image data transmission
Synchronous
Image flip
None
Image rotation
Sensor view (no rotation)
Initial 1D search area
Center
Lighting goal
42
Lighting mode
Illumination priority
Snapshot Snapshot compression
None
Snapshot resolution
Full resolution
Events Snapshot ready event
Not active
Video Select video start condition
N/A
Select video stop condition
N/A
Video on
N/A
Video off
N/A
Video compression
None
Video compression quality
No compression
Video resolution
Full resolution
Video decode mode
Not active
Events Video start event
Not active
Video stop event
Not active
Signature capture Scenario 1-4 Activation
44
Not active
SR30 Handheld Scanner User’s Guide
Page 55
Appendix B, Default Settings
Imager Setting Commands (continued) Command
Default Value
Capture area definition Automatic correction
Both horizontal and vertical
Image validation Focus check
Not active
Image ratio check
Not active
Image processing Projective mapping and resolution
Not active
Contrast enhancement
Disable
Noise reduction
No noise reduction
Edge enhancement
Disable
Image output Output format
Grayscale
Output compression
None
Output compression quality
50
Reset scenario
Configuration and Utility Commands Command
Default Value
Get firmware version
N/A
Get decode version
N/A
Get shutter speed
N/A
Get configuration signature
N/A
Get 1D filter sequence
N/A
Get filter list
N/A
Firmware upgrade with RS-232 cable
N/A
Host Interface Processor (HIP) firmware upgrade
N/A
Optical setup (using configuration bar codes)
Enable
SR30 Handheld Scanner User’s Guide
45
Page 56
Worldwide Headquarters 6001 36th Avenue West Everett, Washington 98203 U.S.A. tel 425.348.2600 fax 425.355.9551 www.intermec.com © 2008 Intermec Technologies Corporation. All rights reserved.
SR30 Handheld Scanner User’s Guide
*123-456-789* P/N 934-017-002