Page 1

Quick Start Guide Kurzanleitung Manual de Consulta Rápida Guía de comienzo rápido

SF51

Cordless Scanner Schnurlos-Scanner Leitor sem Fio Escáner inalámbrico

Page 2

Contents SF51 Cordless Scanner Quick Start Guide . . . . . . . . . . . . . . 3 Kurzanleitung für den Schnurlos-Scanner SF51 . . . . . . . . . . 9 Manual de Consulta Rápida do Leitor sem Fio SF51 . . . . . 16 Guía de comienzo rápido del escáner inalámbrico SF51 . . . 23 ii

Page 3

SF51 Cordless Scanner Quick Start Guide The SF51 Cordless Scanner is a small, rugged handheld scanner that uses a Bluetooth™ radio for RF communications. The SF51 makes data collection easy and includes these features: Scan button Intermec Ready-to-Work indicator

Scanner

Magnetic connector Status light

This guide describes how to set basic parameters to start using the SF51. This device contains permanent magnets that can generate magnetic fields of greater than 10 gauss. Caution should be used by anyone with a Pacemaker, Implantable Cardioverter Defibrillator (ICD), or Heart Failure Device. Check with your doctor for detailed information before using this device.

Out of the Box

Belt clip holder SF51 Cordless Scanner

CD

Documentation 3

Page 4

Charging the SF51 • Place the SF51 in a 1-bay (Model 074645) or 4-bay (Model 074646) charger. The 1-bay charger is shown below.

Status light

The status light on the SF51 turns on to indicate battery charge status. A fully discharged battery charges in approximately 3 hours. For more information, see the instructions that ship with the charger.

Connecting the SF51 to a Host Device You can use Bluetooth radio communications to connect the SF51 to these host devices: • Bluetooth enabled Intermec computer • PC with a USB Bluetooth adapter (P/N 203-771-xxx) • Other Bluetooth enabled devices that support Serial Port Profile (SPP) Before connecting the SF51 to a host device, you need to: • install EasySet version 5.2 or later on your PC. EasySet is available on the CD that ships with the SF51. • note the Bluetooth address of the host device and the SF51. The SF51 Bluetooth address is located in the upper right corner of the label on the back of the SF51.

4

Page 5

Bluetooth address

To connect to an Intermec computer 1 On your PC, start EasySet. Make sure that SF51 is selected as your product. 2 From the EasySet commands window, select Data transmission settings > Bluetooth Parameters > connect/ disconnect. 3 Double-click compose BT address. 4 Enter the Bluetooth address of your Intermec computer and click OK. The bar code appears on the setup sheet. 5 Scan the bar code onscreen with the SF51, or print the bar code setup sheet and scan the bar code. The SF51 beeps once, the green status light flashes once, and the blue Intermec Ready-to-Work™ indicator starts blinking. When the SF51 connects to your Intermec computer, the SF51 emits a series of beeps from low to high, and the blue Intermec Ready-to-Work indicator turns on. The SF51 is ready to scan data. Note: You can also use the Bluetooth Device Utility or the Bluetooth control panel on your Intermec computer. For help, see the documentation for your Intermec computer. To connect to a PC with the USB Bluetooth adapter 1 Install the USB Bluetooth adapter (P/N 203-771-xxx). 2 Connect and pair your SF51 to your host PC. For more information, see the USB Bluetooth Adapter Instructions (P/N 074479) that ship with the adapter. 5

Page 6

Scanning Bar Codes 1 Press the Scan button to turn on the SF51. Once the SF51 establishes a Bluetooth connection, you can scan bar codes. 2 Point the SF51 at the bar code label and hold the SF51 at a slight angle 15 to 25 cm (6 to 10 in) from the label. You can use one of the test bar codes in the next section. 3 Press the Scan button. The red aiming beam turns on. TE *IN

RME

C*

4 If you are scanning a 1D bar code, direct the beam so that it falls across all bars in the bar code label. If you are scanning a 2D bar code, pass the beam over the bar code label in a steady sweeping motion. The scanner emits a crackle sound. When the SF51 successfully reads a bar code label, you hear a single beep and the status light briefly turns green. 5 Release the Scan button.

Using Test Bar Codes The SF51 ships with these bar code symbologies enabled: • Code 39 • Code 128 • UPC/EAN • PDF417 (only available on the SF51 with PDF version) To enable more bar code symbologies, see the SF51 Cordless Scanner User’s Guide (P/N 074474).

6

Page 7

To make sure that your SF51 is working properly 1 Start your data collection application. 2 Scan one of these test bar codes. Code 39 Test Bar Code

* 1 2 3 4 5 6 *

UPC-E Test Bar Code

0

123456

5

The test bar code data should appear in your application.

Troubleshooting Problem

Possible Solution

The SF51 may not be connected to a host. You scan a bar code, the status light flashes red for Make sure the blue Intermec Ready-to2 seconds, and the scanner Work indicator is on and the SF51 is linked to your host device. beeps three times. You press the Scan button, The battery is low. Charge the battery and the status light turns immediately and try scanning again. on and stays red. You cannot establish a Bluetooth connection (the Intermec Ready-to-Work indicator is not on).

Scan the following bar code to reset the scanner to its default configuration and try establishing a link again. You will need to reconfigure the SF51. Administrator Reset to Factory Defaults

\60\08\55\22

7

Page 8

Useful Bar Codes These bar codes can be useful if you need to call Intermec Product Support. Use the Scanner Power Down bar code to turn off the SF51. Use the other bar codes to get SF51 version and Bluetooth address information. If you are viewing this document online, you may be able to scan these bar codes directly onscreen with your SF51. Get Product Version

\30\0F\37\20 Get Sub-System Versions

\60\0F\37\23 Get SF51 Bluetooth Address

\60\0F\37\23 Scanner Power Down

\60\08\2A\46

Where to Go From Here Go to the Intermec web site at www.intermec.com to find manuals as PDF files. To order accessories and printed documentation, contact your local Intermec sales representative. If you have any problems, please visit our Product Support web site at intermec.custhelp.com. Patent Information: This product is protected by one or more patents. Refer to the SF51 Cordless Scanner User’s Guide (P/N 074474) for the list of patents. Electrical Rating: x 5V, 1.5A 8