Page 308
Appendix B
Unit Manager "
"
" NOTE:
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
Parameter information, such as SNMP OID and options, is detailed in Appendix A, “Control Panel Applets.”
Configuration parameters are also configurable using a Unit Manager application which accesses the 700 Series Computer through a web browser on your desktop PC via the SRDEVMGMT.CAB file. To use the Unit Manager, install this CAB file from the 700C Software Tools CDROM. See the Software Tools Help on the 700C Tools CD for assistance. See the Unit Manager Help on the 700C Tools CD for information on using the Unit Manager application.
Data Collection Within the Unit Manager, click Configuration from the left navigation bar, then click the Data Collection icon to access any of these tabs: Symbologies, Symbology ID, Beeper/LED/Buttons, or Virtual Wedge.
Symbologies Within the Unit Manager, select Configuration Management → Data Collection, then click the Symbologies tab to access the following parameters. Options for these parameters are listed on the page provided. These are listed in alphabetical order. " " "
" "
" " " "
Codabar (page A-7) Code 11 (page A-21) Code 128 (page A-10) " Code 128 Options (page A-11) " Code 128 FNC1 Character (page A-12) Code 39 (page A-5) Code 93 (page A-9) " Code 93 Length (page A-9) Datamatrix (page A-23) Interleaved 2 of 5 (page A-18) Matrix 2 of 5 (page A-19) MSI (page A-14) 700 Series Color Mobile Computer User’s Manual
B-1
Page 309
Unit Manager
APPENDIX A
"
" " " " "
PDF 417 (page A-15) " Macro PDF (page A-16) " Micro PDF 417 (page A-17) Plessey (page A-13) QR Code (page A-22) Standard 2 of 5 (page A-6) Telepen (page A-20) UPC/EAN (page A-8)
Symbology ID Within the Unit Manager, select Configuration Management → Data Collection, then click the Symbology ID tab to access the following parameters. Options for these parameters are listed on the page provided. These are listed in alphabetical order. " " "
Prefix (page A-30) Suffix (page A-31) Symbology ID (page A-24) " Codabar user ID (page A-25) " Code 11 user ID (page A-29) " Code 128 user ID (page A-25) " Code 39 user ID (page A-25) " Code 93 user ID (page A-26) " EAN-13 user ID (page A-28) " EAN-8 user ID (page A-28) " Interleaved 2 of 5 user ID (page A-26) " Matrix 2 of 5 user ID (page A-28) " MSI user ID (page A-26) " PDF 417 user ID (page A-26) " Plessey user ID (page A-27) " Standard 2 of 5 user ID (page A-27) " Telepen user ID (page A-28) " UPC-A user ID (page A-27) " UPC-E user ID (page A-27)
Beeper/LED/Button Within the Unit Manager, select Configuration Management → Data Collection, then click the Beeper/LED/Button tab to access the following parameters. Options for these parameters are listed on the page provided. These are listed in alphabetical order. " " " " "
B-2
Beeper Frequency (page A-33) Beeper Volume (page A-32) Good Read Beep Duration (page A-35) Good Read Beeps (page A-34) Record Button (page A-36)
700 Series Color Mobile Computer User’s Manual
Page 310
Unit Manager
APPENDIX B
Virtual Wedge Within the Unit Manager, select Configuration Management → Data Collection, then click the Virtual Wedge tab to access the following parameters. Options for these parameters are listed on the page provided. These are listed in alphabetical order. " " " " "
Code Page (page A-41) Grid (page A-40) Postamble (page A-39) Preamble (page A-38) Virtual Wedge (page A-37)
SNMP Within the Unit Manager, click Configuration from the left navigation bar, then click the SNMP icon to access any of these tabs: Security, Traps, or Identification.
Security Within the Unit Manager, select Configuration Management → SNMP, then click the Security tab to access the following parameters. Options for these parameters are listed on the page provided. These are listed in alphabetical order. " " " " "
Encryption Key (page A-47) Read Encryption (page A-45) Read Only Community (page A-43) Read/Write Community (page A-44) Write Encryption (page A-46)
Traps Within the Unit Manager, select Configuration Management → SNMP, then click the Traps tab to access the following parameters. Options for these parameters are listed on the page provided. These are listed in alphabetical order. " "
Authentication (page A-48) Threshold (page A-49)
Identification Within the Unit Manager, select Configuration Management → SNMP, then click the Identification tab to access the following parameters. Options for these parameters are listed on the page provided. These are listed in alphabetical order. " " "
Contact (page A-50) Location (page A-52) Name (page A-51) 700 Series Color Mobile Computer User’s Manual
B-3
Page 311
Unit Manager
APPENDIX B
Unit Within the Unit Manager, click Configuration from the left navigation bar, then click the Unit icon to access any of these tabs: Date/Time, Display, Keypad, Power Management, or Speaker.
Date/Time Sets the current date and time. Action: Click the Date/Time tab, then select Date or Time and make changes in the entry field, or tap (+) to expand either the Date or Time parameter, select the setting to be changed, then select a value from the drop-down list or enter a new value to change this setting. SNMP OID: Date: 1.3.6.1.4.1.1963.15.501.2.1.0 Time: 1.3.6.1.4.1.1963.15.501.2.2.0 Options: Date Time
B-4
Year 0000–999 (1999) Month 1–12 (6) Day 1–31 (1) Hour 0–23 (0) Minute 0–59 (00) Second 0–59 (00)
700 Series Color Mobile Computer User’s Manual
Page 312
Unit Manager
APPENDIX B
Backlight Timeout Sets the length of time that the display backlight remains on. If you set a longer timeout value, you use the battery power at a faster rate. Action: Click the Display tab, then select an option from the Backlight timeout drop-down list. SNMP OID: 1.3.6.1.4.1.1963.15.13.1.0 Syntax: DFdata where data is any of the following: 10 10 seconds 30 30 seconds 60 1 minute (default) 120 2 minutes 180 3 minutes 240 4 minutes 300 5 minutes
700 Series Color Mobile Computer User’s Manual
B-5
Page 313
Unit Manager
APPENDIX B
Key Clicks Enables or disables the keypad clicks. The 700 Series Computer emits a click each time you press a key or decode a row of a two-dimensional symbology. Action: Click the Keypad tab, then select an option from the Key clicks drop-down list. SNMP OID: 1.3.6.1.4.1.1963.15.12.1.0 Syntax: KCdata where data is any of the following: 0 Disable clicks 1 Enable soft key clicks 2 Enable loud key clicks (default)
B-6
700 Series Color Mobile Computer User’s Manual
Page 314
Unit Manager
APPENDIX B
Automatic Shutoff Sets the length of time the 700 Series Computer remains on when there is no activity. When you turn on the 700 Computer, it either resumes exactly where it was when you turned it off or boots and restarts your application. Action: Click the Power Management tab, then select an option from the Automatic shutoff drop-down list. SNMP OID: 1.3.6.1.4.1.1963.15.1 1.3.0 Syntax: EZdata where data is any of the following: 1 1 minute 2 2 minutes 3 3 minutes (default) 4 4 minutes 5 5 minutes
700 Series Color Mobile Computer User’s Manual
B-7
Page 315
Unit Manager
APPENDIX B
Volume Changes the volume of all audio signals. Action: Click the Speaker tab, then select an option from the Volume drop-down list. SNMP OID: 1.3.6.1.4.1.1963.15.3.1.3.0 Syntax: BVdata where data is any of the following: 0 Off 1 Very quiet 2 Quiet 3 Normal (default) 4 Loud 5 Very loud
B-8
700 Series Color Mobile Computer User’s Manual
Page 316
Unit Manager
APPENDIX B
Using Reader Commands After the 700 Series Computer is connected to your network, you can send the 700 Series Computer a reader command from an application to perform a task, such as changing the time and date. Some reader commands temporarily override the configuration settings and some change the configuration settings.
Change Configuration The Change Configuration command must precede any configuration command. If you enter a valid string, the 700 Series Computer configuration is modified and the computer emits a high beep. To send the Change Configuration command through the network, use the $+ [command] syntax where command is the two-letter command syntax for the configuration command followed by the value to be set for that command. You can also make changes to several different commands by using the $+ [command]...[command n] syntax. There are seven configuration command settings that can be changed in this way. See each command for information on respective acceptable “data” values. Command
Syntax
Audio Volume Automatic Shutoff Backlight Timeout Key Clicks Virtual Wedge Grid Virtual Wedge Postamble Virtual Wedge Preamble
BVdata EZdata DFdata KCdata AFdata AEdata ADdata
" NOTE:
See Appendix A, “Control Panel Applets” for more information about the Virtual Wedge Postamble and Virtual Wedge Preamble commands.
EXAMPLE 1:
To change the Beep Volume to Off, you can send this string to the 700 Series Computer through the network: $+BV0 where: $+ Indicates Change Configuration. BV Specifies the Audio Volume parameter. 0 Specifies a value of Off.
EXAMPLE 2:
To change the Beep Volume to Very Quiet and the Virtual Wedge Grid to 123: $+BV1AF123 where: $+ Indicates Change Configuration BV1 Specifies Audio Volume, set to Very Quiet (1) AF123 Specifies Virtual Wedge Grid, set to a value of 123.
700 Series Color Mobile Computer User’s Manual
B-9
Page 317
Unit Manager
APPENDIX B
Set Time and Date This command sets the date and time on the 700 Series Computer. The default date and time is June 1, 1999 at 12:00 AM. From the network, send the following: /+ yyyymmddhhmmss where acceptable values for the date are: yyyy mm dd hh mm ss
0000–9999 01–12 01–31 00–23 00–59 00–59
Year Month of the year Day of the month Hour Minutes Seconds
You can also set the time and date by using Configuration Management in Unit Manager, or by using the Clock control panel applet in the Settings menu. To access this control panel applet, tap Start → Settings → the System tab → the Clock icon to access its control panel applet.
B-10