Page 280
Control Panel Applets
APPENDIX A
Suffix
Appends a string of up to 20 ASCII characters to all scanned data. Action: Tap the Suffix parameter, then enter a suffix value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.30.1 Options: Acceptable values are up to 20 ASCII characters. Embedded null (<NUL >) characters are not allowed. Default is no characters (disabled).
700 Series Color Mobile Computer User’s Manual
A-31
Page 281
Control Panel Applets
APPENDIX A
Beeper/LED/Buttons To access the settings from the 700 Series Computer, tap Start → Settings → the System tab → the Data Collection icon to access its control panel applet. Use the right and left arrows to scroll to the Beeper/LED/Buttons tab, then tap this tab to access its parameters. Most of these functions are not available when using an imager. The following table shows which functions are supported either by an imager or by a laser scanner.
Beeper Function
Imager
Laser Scanner
Beeper Volume
X
X
Beeper Frequency
X
Good Read Beeps
X
Good Read Beep Duration
X
Record Button
X
X
The following are parameters for features on the700 Series Computer. Note that these are listed in the order of their appearance.
Beeper Volume
Sets the volume for the good read beep. Action: Tap the Beeper volume parameter, then select an option to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.1.4.1.6.1 Options: 0 Low 1 High (default) 2 Medium 3 Vibrate
A-32
700 Series Color Mobile Computer User’s Manual
Page 282
Control Panel Applets
APPENDIX A
Beeper Frequency
Sets the frequency for the good read beep. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap the Beeper frequency parameter, then enter a frequency value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.1.4.1.7.1 Options: 1000–4095 (default is 2090)
700 Series Color Mobile Computer User’s Manual
A-33
Page 283
Control Panel Applets
APPENDIX A
Good Read Beeps
Sets the number of good read beeps. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap the Good read beeps parameter, then select an option to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.1.4.1.8.1 Options: 0 No beeps 1 One beep (default) 2 Two beeps
A-34
700 Series Color Mobile Computer User’s Manual
Page 284
Control Panel Applets
APPENDIX A
Good Read Beep Duration
Sets the duration of the good read beep. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap the Good read beep duration parameter, then enter a duration value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.1.4.1.9.1 Options: 0–2550
Beep duration in milliseconds. (default is 80)
700 Series Color Mobile Computer User’s Manual
A-35
Page 285
Control Panel Applets
APPENDIX A
Record Button
This allows the configuration of the left scan button on the 700 Series Computer to either activate the scanner or the Record feature via a Pocket PC application. See Section 2, “Pocket PC 2002,” for more information about recording a message. Action: Tap the Record button parameter, then select either option to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.1.4.1.13.1 Options: 0 Scanner (default) 1 Record
A-36
700 Series Color Mobile Computer User’s Manual
Page 286
Control Panel Applets
APPENDIX A
Virtual Wedge To access the settings from the 700 Series Computer, tap Start → Settings → the System tab → the Data Collection icon to access its control panel applet. Use the right and left arrows to scroll to the Virtual Wedge tab, then tap this tab to access its parameters. The following are parameters for the virtual wedge scanner. Note that these are listed in the order of their appearance within the Virtual Wedge tab.
Virtual Wedge
Enables or disables the virtual wedge for the internal scanner. The virtual wedge retrieves scanned Automatic Data Collection (ADC) data and sends it to the keypad driver so that the 700 Series Computer can receive and interpret the data as keypad input. Because the virtual wedge translates incoming data into keypad input, the size of the keypad buffer limits the effective length of the label to 128 characters. Longer labels may be truncated. For labels of more than 128 characters, you need to develop an application that bypasses the keypad buffer. Action: Tap the Virtual Wedge parameter, then tap an option to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.2.1.1.2.1 Options: 0 Disable 1 Enable (default)
700 Series Color Mobile Computer User’s Manual
A-37
Page 287
Control Panel Applets
APPENDIX A
Preamble
Sets the preamble that precedes any data you scan with the 700 Series Computer. Common preambles include a data location number or an operator number. Action: Tap the Preamble parameter, then enter a preamble value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.2.1.1.3.1 Syntax: ADdata where data is any acceptable values up to 31 ASCII characters. Embedded null (<NUL >) characters are not allowed. Default is no characters (disabled).
" NOTE:
When you enter the AD command without data, the preamble is disabled. If you want to use quotation marks or these combinations of characters: AD AE AF KC BV EX DF as part of the appended data, separate those characters from the AD command with quotes. If you do not use quotes as described here, the 700 Series Computer will interpret the characters as another configuration command. See the following example:
EXAMPLE:
To use the two-character string BV as a preamble, scan this command (as a Code 39 label) or send this command through the network: $+AD“BV”
A-38
700 Series Color Mobile Computer User’s Manual
Page 288
Control Panel Applets
APPENDIX A
Postamble
Sets the postamble that is appended to any data you scan with the 700 Series Computer. Common postambles include cursor controls, such as tabs or carriage return line feeds. Action: Tap the Postamble parameter, then enter a postamble value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.2.1.1.4.1 Syntax: AEdata where data is any acceptable values up to 31 ASCII characters. Embedded null (<NUL >) characters are not allowed. Default is the tab character (\t).
" NOTE:
When you enter the AE command without data, the postamble is disabled. If you want to use quotation marks or these combinations of characters: AD AE AF KC BV EX DF as part of the appended data, separate those characters from the AE command with quotes. If you do not use quotes as described here, the 700 Series Computer will interpret the characters as another configuration command. See the following example:
EXAMPLE:
To use the two-character string BV as a postamble, scan this command (as a Code 39 label) or send this command through the network: $+AE“BV”
700 Series Color Mobile Computer User’s Manual
A-39
Page 289
Control Panel Applets
APPENDIX A
Grid
Sets the virtual wedge grid, which filters the data coming from this 700 Series Computer. The data server supports data filtering, which allows you to selectively send scanned data. The virtual wedge grid is similar to the “format” argument of the C Runtime Library scan function. Action: Tap the Grid parameter, then enter a grid value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.2.1.1.5.1 Syntax: AF<symID> filter-expression= > editing-expression where: <symID> The AIM symbology ID. filter-expression Any character string that includes valid filter expression values, and editing-expression is any character string that includes valid editing expression values. <width> is any positive integer or NULL. A NULL width means that the field type (defined next) applies all the way to the end of the data string. A non-NULL width means that the field applies to that many characters of data. The grid can be up to 240 characters in length. Default is NULL.
A-40
700 Series Color Mobile Computer User’s Manual