Page 183

Scanner Support

SECTION 6

IS9CConfig::GetStandard2of5

This function retrieves the current Standard 2 of 5 settings. Syntax: HRESULT IS9CConfig::GetStandard2of5( ITC_STANDARD2OF5_DECODING* peDecode, ITC_STANDARD2OF5_FORMAT* peFormat, ITC_STANDARD2OF5_CHECK_DIGIT* peCheck, ITC_BARCODE_LENGTH_ID* peLengthId, BYTE rgbLengthBuff, DWORD* pdwNumBytes ); Parameters: peDecode

[out]

Pointer to the ITC_STANDARD2OF5_DECODING location to receive the decoding for Standard 2 of 5 symbology.

peFormat

[out]

Pointer to the ITC_STANDARD2OF5_FORMAT location to receive the format.

peCheck

[out]

Pointer to the ITC_STANDARD2OF5_CHECK_DIGIT location to receive Modulo 10 check digit.

peLengthId

[out]

Pointer to the ITC_BARCODE_LENGTH_ID location to receive an indicator of either ITC_BARCODE_LENGTH or ITC_BARCODE_FIXED_LENGTH.

rgbLengthBuff

[out,size_is(3)] An array of bytes to receives 1 byte of data for ITC_BARCODE_LENGTH, or 3 bytes of data for ITC_BARCODE_FIXED_LENGTH.

pdwNumBytes

[out]

Pointer to the DWORD location to receive a number indicating number of bytes in rbgLengthBuff[]: 1 byte for ITC_BARCODE_LENGTH or 3 bytes for ITC_BARCODE_FIXED_LENGTH.

Return Values: HRESULT that indicates success or failure.

6-46

700 Series Color Mobile Computer User’s Manual

Page 184

Scanner Support

SECTION 6

IS9CConfig::SetStandard2of5

This function updates the Standard 2 of 5 settings with new values. Syntax: HRESULT IS9CConfig::SetStandard2of5( ITC_STANDARD2OF5_DECODING eDecode, ITC_STANDARD2OF5_FORMAT eFormat, ITC_STANDARD2OF5_CHECK_DIGIT eCheck, ITC_BARCODE_LENGTH_ID eLengthId, BYTE rgbLengthBuff[], DWORD dwNumBytes ); Parameters: eDecode

[in] Identifies the decoding for Standard 2 of 5 symbology.

eFormat

[in] Identifies the format.

eCheck

[in] Identifies the Modulo 10 check digit.

eLengthId

[in] Use ITC_BARCODE_LENGTH_NO_CHANGE to indicate no change for bar code length. Use ITC_BARCODE_LENGTH for any length and minimum length, and set rgbLengthBuff[0] to a valid length value. Use ITC_BARCODE_FIXED_LENGTH to compose 1 or 2 or 3 fixed lengths, and set 3 bytes: rgbLengthBuff[0], rgbLengthBuff[1], rgbLengthBuff[2] with valid values.

rgbLengthBuff

[in,size_is(dwNumBytes)] An array of bytes containing bar code lengths when eLengthId = ITC_BARCODE_LENGTH or ITC_BARCODE_FIXED_LENGTH.

dwNumBytes

[in] Number of bytes in rbgLengthBuff[]. For S9C, this value is: 1 When eLengthId = ITC_BARCODE_LENGTH, 3 When eLengthId = ITC_BARCODE_FIXED_LENGTH.

Return Values: HRESULT that indicates success or failure.

Standard 2 of 5 Default Settings Parameter

Default

Valid Range

Decoding

Not Active

ITC_STANDARD2OF5_DECODING

Format

Identicon (6 Start/Stop bars)

ITC_STANDARD2OF5_FORMAT

Check Digit

Not Used

ITC_STANDARD2OF5_CHECK_DIGIT

Bar Code Length

Minimum Length = 6

0x00–0xFE ITC_BC_LENGTH_NO_CHANGE

700 Series Color Mobile Computer User’s Manual

6-47

Page 185

Scanner Support

SECTION 6

Standard 2 of 5 Enumerations typedef enum tagStandard2of5Decoding { ITC_STANDARD2OF5_NOTACTIVE = 0, // Default ITC_STANDARD2OF5_ACTIVE = 1, ITC_STANDARD2OF5_NO_CHANGE = 255 } ITC_STANDARD2OF5_DECODING; typedef enum tagStandard2of5Format { ITC_STANDARD2OF5_FORMAT_IDENTICON, // Default ITC_STANDARD2OF5_FORMAT_COMPUTER_IDENTICS, ITC_STANDARD2OF5_FORMAT_NO_CHANGE = 255 } ITC_STANDARD2OF5_FORMAT; typedef enum tagStandard2of5CheckDigit { ITC_STANDARD2OF5_CHECK_NOTUSED, // Default ITC_STANDARD2OF5_CHECK_XMIT, ITC_STANDARD2OF5_CHECK_NOTXMIT, ITC_STANDARD2OF5_CHECK_NO_CHANGE = 255 } ITC_STANDARD2OF5_CHECK_DIGIT; typedef enum tagBarcodeLengthId { ITC_BARCODE_LENGTH = 0, ITC_BARCODE_FIXED_LENGTH, ITC_BARCODE_LENGTH_NO_CHANGE = 255 } ITC_BARCODE_LENGTH_ID;

6-48

700 Series Color Mobile Computer User’s Manual

Page 186

Scanner Support

SECTION 6

IS9CConfig::GetTelepen

This function retrieves the current Telepen settings. Syntax: HRESULT IS9CConfig::GetTelepen( ITC_TELEPEN_DECODING* peDecode, ITC_TELEPEN_FORMAT* peFormat ); Parameters: peDecode [out] peFormat [out]

Pointer to the ITC_TELEPEN_DECODING location to receive the decoding for TELEPEN symbology. Pointer to the ITC_TELEPEN_FORMAT location to receive the format.

Return Values: HRESULT that indicates success or failure.

IS9CConfig::SetTelepen

This function updates the Telepen settings with new values. Syntax: HRESULT IS9CConfig::SetTelepen( ITC_TELEPEN_DECODING* eDecode, ITC_TELEPEN_FORMAT* eFormat ); Parameters: eDecode eFormat

[in] Identifies the decoding for Telepen symbology. [in] Identifies the format.

Return Values: HRESULT that indicates success or failure.

Telepen Default Settings Parameter

Default

Valid Range

Decoding

Not Active

ITC_TELEPEN_DECODING

Format

ASCII

ITC_TELEPEN_FORMAT

Telepen Enumerations typedef enum tagTelepenDecoding { ITC_TELEPEN_NOTACTIVE = 0, // Default ITC_TELEPEN_ACTIVE = 1, ITC_TELEPEN_NO_CHANGE = 255 } ITC_TELEPEN_DECODING; typedef enum tagTelepenDecoding { ITC_TELEPEN_FORMAT_ASCII, // Default ITC_TELEPEN_FORMAT_NUMERIC, ITC_TELEPEN_FORMAT_NO_CHANGE = 255 } ITC_TELEPEN_FORMAT;

700 Series Color Mobile Computer User’s Manual

6-49

Page 187

Scanner Support

SECTION 6

IS9CConfig::GetUpcEan This function retrieves the current UPC/EAN settings. Syntax: HRESULT IS9CConfig::GetUpcEan( ITC_UPCEAN_DECODING* upceanDecode, ITC_UPCA_SELECT* upcASelect, ITC_UPCE_SELECT* upcESelect, ITC_EAN8_SELECT* ean8Select, ITC_EAN13_SELECT* ean13Select, ITC_UPCEAN_ADDON_DIGITS* upcAddOnDigits, ITC_UPCEAN_ADDON_TWO* upcAddOn2, ITC_UPCEAN_ADDON_FIVE* upcAddOn5, ITC_UPCA_CHECK_DIGIT* upcACheck, ITC_UPCE_CHECK_DIGIT* upcECheck, ITC_EAN8_CHECK_DIGIT* ean8Check, ITC_EAN13_CHECK_DIGIT* ean13Check, ITC_UPCA_NUMBER_SYSTEM* upcANumSystem, ITC_UPCE_NUMBER_SYSTEM* upcENumSystem, ITC_UPCA_REENCODE* upcAReencode, ITC_UPCE_REENCODE* upcEReencode, ITC_EAN8_REENCODE* ean8Reencode ); Parameters: upceanDecode

[out]

Pointer to the ITC_UPCEAN_DECODING location to receive the decoding for UPC/EAN symbology.

upcASelect

[out]

Pointer to the ITC_UPCA_SELECT location to receive the UPC-A selection state.

upcESelect

[out]

Pointer to the ITC_UPCE_SELECT location to receive the UPC-E selection state.

ean8Select

[out]

Pointer to the ITC_EAN8_SELECT location to receive the EAN-8 selection state.

ean13Select

[out]

Pointer to the ITC_EAN13_SELECT location to receive the EAN-13 selection state.

upcAddOnDigits [out]

Pointer to the ITC_UPCEAN_ADDON_DIGITS location to receive the add-on digits.

upcAddOn2

[out]

Pointer to the ITC_UPCEAN_ADDON_TWO location to receive the add-on 2 digits.

upcAddOn5

[out]

Pointer to the ITC_UPCEAN_ADDON_FIVE location to receive the add-on 5 digits.

upcACheck

[out]

Pointer to the ITC_UPCA_CHECK_DIGIT location to receive the UPC-A check digit.

upcECheck

[out]

Pointer to the ITC_UPCE_CHECK_DIGIT location to receive the UPC-E check digit.

ean8Check

[out]

Pointer to the ITC_EAN8_CHECK_DIGIT location to receive the EAN-8 check digit.

ean13Check

[out]

Pointer to the ITC_EAN13_CHECK_DIGIT location to receive the EAN-13 check digit.

upcANumSystem [out]

6-50

700 Series Color Mobile Computer User’s Manual

Pointer to the ITC_UPCA_NUMBER_SYSTEM location to receive the UPC-A number system.

Page 188

Scanner Support

SECTION 6 upcENumSystem [out] upcAReencode

[out] upcEReencode

[out] ean8Reencode

[out]

Pointer to the ITC_UPCE_NUMBER_SYSTEM location to receive the UPC-E number system. Pointer to the ITC_UPCA_REENCODE location to receive the UPC-A reencoding. Pointer to the ITC_UPCE_REENCODE location to receive the UPC-E reencoding. Pointer to the ITC_EAN8_REENCODE location to receive the EAN-8 reencoding.

Return Values: HRESULT that indicates success or failure.

IS9CConfig::SetUpcEan

This function updates the UPC/EAN settings with new values. Syntax: HRESULT IS9CConfig::SetUpcEan( ITC_UPCEAN_DECODING upceanDecode, ITC_UPCA_SELECT upcASelect, ITC_UPCE_SELECT upcESelect, ITC_EAN8_SELECT ean8Select, ITC_EAN13_SELECT ean13Select, ITC_UPCEAN_ADDON_DIGITS upcAddOnDigits, ITC_UPCEAN_ADDON_TWO upcAddOn2, ITC_UPCEAN_ADDON_FIVE upcAddOn5, ITC_UPCA_CHECK_DIGIT upcACheck, ITC_UPCE_CHECK_DIGIT upcECheck, ITC_EAN8_CHECK_DIGIT ean8Check, ITC_EAN13_CHECK_DIGIT ean13Check, ITC_UPCA_NUMBER_SYSTEM upcANumSystem, ITC_UPCE_NUMBER_SYSTEM upcENumSystem, ITC_UPCA_REENCODE upcAReencode, ITC_UPCE_REENCODE upcEReencode, ITC_EAN8_REENCODE ean8Reencode ); Parameters: upceanDecode [in] upcASelect [in] upcESelect [in] ean8Select [in] ean13Select [in] upcAddOnDigits [in] upcAddOn2 [in] upcAddOn5 [in] upcACheck [in] upcECheck [in] ean8Check [in] ean13Check [in] upcANumSystem [in] upcENumSystem [in] upcAReencode [in] upcEReencode [in] ean8Reencode [in]

Identifies the decoding for UPC/EAN symbology. Identifies the UPC-A selection state. Identifies the UPC-E selection state. Identifies the EAN-8 selection state. Identifies the EAN-13 selection state. Identifies the Add-on digits. Identifies the Add-on 2 digits. Identifies the Add-on 5 digits. Identifies the UPC-A check digit. Identifies the UPC-E check digit. Identifies the EAN-8 check digit. Identifies the EAN-13 check digit. Identifies the UPC-A number system. Identifies the UPC-E number system. Identifies the UPC-A reencoding. Identifies the UPC-E reencoding. Identifies the EAN-8 reencoding. 700 Series Color Mobile Computer User’s Manual

6-51

Page 189

Scanner Support

SECTION 6

Return Values: HRESULT that indicates success or failure.

UPC/EAN Default Settings Parameter

Default

Valid Range

Decoding

ITC_UPCEAN_NO_CHANGE

UPC-A UPC-E EAN-8 EAN-13 Add On Digits Add On 2 Digits Add On 5 Digits UPC-A Check Digit UPC-E Check Digit EAN-8 Check Digit EAN-13 Check Digit UPC-A Number System UPC-E Number System Reencode UPC-A Reencode UPC-E Reencode EAN-8

Active Active Active Active Not Required Not Active Not Active Transmitted Transmitted Transmitted Transmitted Transmitted Transmitted UPC-A transmitted as EAN-13 UPC-E transmitted as UPC-E EAN-8 transmitted as EAN-8

This parameter is no longer used and must be set to this value. ITC_UPCA_SELECT ITC_UPCE_SELECT ITC_EAN8_SELECT ITC_EAN13_SELECT ITC_UPCEAN_ADDON_DIGITS ITC_UPCEAN_ADDON_TWO ITC_UPCEAN_ADDON_FIVE ITC_UPCA_CHECK_DIGIT ITC_UPCE_CHECK_DIGIT ITC_EAN8_CHECK_DIGIT ITC_EAN13_CHECK_DIGIT ITC_UPCA_NUMBER_SYSTEM ITC_UPCE_NUMBER_SYSTEM ITC_UPCA_REENCODE ITC_UPCE_REENCODE ITC_EAN8_REENCODE

UPC/EAN Enumerations typedef enum tagUpcEanDecoding { ITC_UPCEAN_NOTACTIVE = 0, ITC_UPCEAN_ACTIVE = 1, ITC_UPCEAN_NO_CHANGE = 255 } ITC_UPCEAN_DECODING; typedef enum tagUpcASelect { ITC_UPCA_DEACTIVATE, ITC_UPCA_ACTIVATE, ITC_UPCA_NO_CHANGE = 255 } ITC_UPCA_SELECT; typedef enum tagUpcESelect { ITC_UPCE_DEACTIVATE, ITC_UPCE_ACTIVATE, ITC_UPCE_NO_CHANGE = 255 } ITC_UPCE_SELECT; typedef enum tagEan8Select { ITC_EAN8_DEACTIVATE, ITC_EAN8_ACTIVATE, ITC_EAN8_NO_CHANGE = 255 } ITC_EAN8_SELECT; typedef enum tagEan13Select { ITC_EAN13_DEACTIVATE, ITC_EAN13_ACTIVATE, ITC_EAN13_NO_CHANGE = 255 } ITC_EAN13_SELECT; typedef enum tagUpcEanAddonDigits { ITC_UPCEAN_ADDON_NOT_REQUIRED, ITC_UPCEAN_ADDON_REQUIRED, ITC_UPCEAN_ADDON_NO_CHANGE = 255

6-52

700 Series Color Mobile Computer User’s Manual

// Default

// Default

// Default

// Default

// Default

// Default

Page 190

Scanner Support

SECTION 6

} ITC_UPCEAN_ADDON_DIGITS; typedef enum tagUpcEanAddonTwo { ITC_UPCEAN_ADDON_TWO_NOTACTIVE = 0, ITC_UPCEAN_ADDON_TWO_ACTIVE = 1, ITC_UPCEAN_ADDON_TWO_NO_CHANGE = 255 } ITC_UPCEAN_ADDON_TWO; typedef enum tagUpcEanAddonFive { ITC_UPCEAN_ADDON_FIVE_NOTACTIVE = 0, ITC_UPCEAN_ADDON_FIVE_ACTIVE = 1, ITC_UPCEAN_ADDON_FIVE_NO_CHANGE = 255 } ITC_UPCEAN_ADDON_FIVE; typedef enum tagUpcACheckDigit { ITC_UPCA_CHECK_NOTXMIT = 0, ITC_UPCA_CHECK_XMIT = 1, ITC_UPCA_CHECK_NO_CHANGE = 255 } ITC_UPCA_CHECK_DIGIT; typedef enum tagUpcECheckDigit { ITC_UPCE_CHECK_NOTXMIT = 0, ITC_UPCE_CHECK_XMIT = 1, ITC_UPCE_CHECK_NO_CHANGE = 255 } ITC_UPCE_CHECK_DIGIT; typedef enum tagEan8CheckDigit { ITC_EAN8_CHECK_NOTXMIT = 0, ITC_EAN8_CHECK_XMIT = 1, ITC_EAN8_CHECK_NO_CHANGE = 255 } ITC_EAN8_CHECK_DIGIT; typedef enum tagEan13CheckDigit { ITC_EAN13_CHECK_NOTXMIT = 0, ITC_EAN13_CHECK_XMIT = 1, ITC_EAN13_CHECK_NO_CHANGE = 255 } ITC_EAN13_CHECK_DIGIT; typedef enum tagUpcANumberSystem { ITC_UPCA_NUM_SYS_NOTXMIT = 0, ITC_UPCA_NUM_SYS_XMIT = 1, ITC_UPCA_NUM_SYS_NO_CHANGE = 255 } ITC_UPCA_NUMBER_SYSTEM; typedef enum tagUpcENumberSystem { ITC_UPCE_NUM_SYS_NOTXMIT = 0, ITC_UPCE_NUM_SYS_XMIT = 1, ITC_UPCE_NUM_SYS_NO_CHANGE = 255 } ITC_UPCE_NUMBER_SYSTEM; typedef enum tagUpcAReencode { ITC_UPCA_XMIT_AS_EAN13, ITC_UPCA_XMIT_AS_UPCA, ITC_UPCA_XMIT_NO_CHANGE = 255 } ITC_UPCA_REENCODE; typedef enum tagUpcEReencode { ITC_UPCE_XMIT_AS_UPCE, ITC_UPCE_XMIT_AS_UPCA, ITC_UPCE_XMIT_NO_CHANGE = 255 } ITC_UPCE_REENCODE; typedef enum tagEan8Reencode { ITC_EAN8_XMIT_AS_EAN8, ITC_EAN8_XMIT_AS_EAN13, ITC_EAN8_XMIT_NO_CHANGE = 255 } ITC_EAN8_REENCODE;

// Default

// Default

// Default

// Default

// Default

// Default

// Default

// Default

// Default

// Default

//Default

700 Series Color Mobile Computer User’s Manual

6-53

Page 191

Scanner Support

SECTION 6

IS9CConfig2 Functions This interface is derived from the IS9CConfig interface and provides additional methods that can be used to set and retrieve the 700 Series Computer’s bar code configuration. All supported symbologies are initialized to their defaults when the S9C firmware is loaded. GET/SET functions use enumerations as their parameters. In most enumerations, there is an enumerator xx_NO_CHANGE (such as ITC_CODE39_NO_CHANGE), where xx refers to a particular enumeration. This enumerator can be used during a call to a SET to indicate that no change is to be made to that particular parameter. This prevents the called function from having to format the same S9C command and send it down to the scanner. To specify a bar code length of “any length,” use a value of “0” for the bar code length argument. IS9CConfig2 functions are the following. IS9CCONFIG.H is the header file and ITCUUID.LIB contains the IID_IADC Interface GUID value used to obtain the interface. " " " " " " " " " "

6-54

IS9CConfig2::GetCode11 (page 6-55) IS9CConfig2::SetCode11 (page 6-55) IS9CConfig2::GetCustomSymIds (page 6-56) IS9CConfig2::SetCustomSymIds (page 6-56) IS9CConfig2::GetGlobalAmble (page 6-58) IS9CConfig2::SetGlobalAmble (page 6-58) IS9CConfig2::GetPDF417Ext (page 6-59) IS9CConfig2::SetPDF417Ext (page 6-59) IS9CConfig2::GetSymIdXmit (page 6-60) IS9CConfig2::SetSymIdXmit (page 6-60)

700 Series Color Mobile Computer User’s Manual