Page 81

APPENDIX B - M ERCURY SPECIFICATIONS q Radio, Frequency: 2.4 - 2.4835 GHz, Compatible with the Proxim RangeLAN2, Technology: Frequency hopping, spread spectrum, Channels: 15 independent, Output power: 100 mW, Data rate: 1.6 Mbits/sec, Modulation: 4fsk (bsk in back off mode) q Serial Interface, Data rates: 112.5 to 230,400 baud, Data format: 7 or 8 data bits; 1, 1.5, or 2 stop bits; even, odd, or no parity, Control lines: TxD, RxD, RTS, CTS, DTS, DSR @ RS-232 levels, Connector: Female DB-9, Configure and Reset control lines, Pinout (wired to the DCE [Data Communication Equiment] specification), except for pins 1 and 9 1 - Configure, 2 - Tx, 3 - Rx, 4 - DTR, 5 - GND, 6 - DSR, 7 - RTS, 8 - CTS, 9 - Reset q Ethernet Interface, Data rate: 10Mbit, Connector: RJ-45 (10Base-T), Pinout 1 - Tx+, 2 - Tx- 3 - Rx+, 4 - NC, 5 - NC, 6 - Rx-, 7 - NC, 8 - NC

71

Page 82

q Software, Pass-through mode > transparent to application > off-line configuration > line length, delimiters, input timeout as message format options q Power, Input voltage: 7.5 - 15 VDC, Current consumption: CPU

Radio

Total

Sleep

12mA

2mA

14mA

Receive

125mA

175mA

300mA

Transmit

125mA

350mA

475mA, Power connector: 2.5 mm DC power jack q Physical, Imperial Dimensions: 5.5 x 2.77 x .88 inches, weight: 10 Ounces, Metric Dimensions: 14.0 x 7.0 x 2.2 centimeters, weight: 200 grams, Temperature: 20° to 60°C, Humidity: 20% to 90% (non-condensing)

Nomadic Communications’ Mercury radios are certified under the FCC’s (Part 15) spread spectrum regulations allowing for their unlicensed use in the United States. Range will vary depending on a number of factors including the physical environment between Mercury units. Power supplies other than the one provided may cause damage and will void the warranty. Swivel antenna attached with a non-standard connector.

72

Page 83

APPENDIX C - SERIAL PORT SPECIFICATIONS This appendix describes the Mercury’s serial port specification. The Mercury unit uses the RS-232 serial port standard for communicating between a DTE (Data Terminal Equipment) device and a DCE (Data Communications Equipment) device, where the Mercury unit conforms to the DCE side of the connection and the user's device or terminal must conform to the DTE side. Note that the serial cable Nomadic Communications provides with the Mercury unit complies with this standard. The necessary serial cable pinout is shown in Figure B-1. The cable is wired to be a standard 9-pin straight-thru from a computer or terminal. The computer or terminal transmits data on pin 3 and receives data on pin 2. Similarly, the Mercury unit receives data on pin 3 and transmits data on pin 2. Category Data

Pin 3 2

Signal Name Transmitted Data Received Data

Abbr. TD RD

Control

7 8 6 4

Request To Send Clear To Send Data Set Ready Data Terminal Ready

RTS CTS DSR DTR

Electrical

5

Signal Ground

System

1 9

Configure Reset

Figure B-1 Cable Pinout Description

The Mercury is configured to ultimately support two sets of handshake lines for flow control: RTS/CTS (Request to Send/Clear to Send), and DTR/DSR (Data Terminal Ready/Data Set Ready). If you intend to use a cable other than the one that came in the package, there are two pins you should be aware of and make sure are not connected on the Mercury side.

73

Page 84

Pin 1 on the DB-9 side of the cable is the Configure pin. Grounding and then bringing high this pin on the Mercury will cause the Setup Mode main menu to come up in the same way that pressing the Configure button will. If the pin is left grounded, the Mercury will be in a constant state of trying to bring up the menu. You should not have this pin connected. Pin 9 on the DB-9 side of the cable is the Reset pin. Forcing this pin to ground and back to 5V will reset the Mercury in the same way it would if power were turned off and back on. If this pin left grounded, the Mercury will be in a constant reset state. You should not have this pin connected.

74

Page 85

APPENDIX D - LED STATUS INDICATORS AND ERRORS MERCURY-RF1 AND M ERCURY-EN LEDS There are eight LEDs on the Mercury-RF1 and Mercury-EN: q

Power – Lights when power is applied.

q

Error – Lights when the software detects an error condition.

q

Serial Tx – Lights when the Mercury is transmitting data through the serial port.

q

Serial Rx – Lights when the Mercury is receiving data from the serial port.

q

Master – Lights when the Mercury is acting as domain Master.

q

Station – Lights when the Mercury is synchronized to a Master.

q

CD – Lights when the radio detects a carrier.

q

Radio Tx/Rx – Lights with the radio is transmitting or receiving a data packet.

MERCURY-EN LED S There are two additional LEDs on the Mercury-EN: q

Link – Lights when a network is detected to be connected to the other side of the 10Base-T cable.

q

Lan Tx/Rx – Lights when network activity is present on the 10Base-T cable.

ERROR LED Errors are indicated by the unit's Error LED. Upon power-up, the Error LED will blink very briefly. If, however, the error light stays on, this indicates either a hardware or configuration error. In order to determine which one, connect the Mercury to a PC or terminal using the supplied serial cable (not one of your own making) and

75

Page 86

press the Configure button (see Chapter 5, Configuration). If the menu appears, it is a configuration error, and you can view the Event Log to determine the nature of the error. If the menu does not appear, try disconnecting the serial cable from the Mercury and turning the power off and back on; if the Error LED remains lit, call Nomadic Communications Customer Service (at 650/988-7200) for assistance. If the Error LED does not remain on in this case, check the serial cable you are using to insure that pins 1 and 9 are disconnected. If you are sure they are (i.e., the pins are physically missing from the connector), call Customer Service for assistance; otherwise, change the serial cable you are using to a properly modified one. When the Mercury unit is placed into sleep mode, the Power LED will be dimmed and the rest of the LEDs will be turned off for the duration of the standby operation. When the unit leaves the standby mode, the LEDs will come back on if they are configured to do so. In any case, if a serious error condition occurs (i.e., hardware failure or configuration error), the LEDs will always come back on, regardless of their configured state. The LEDs will not come back on for errors such as UART framing and parity errors although these errors will still be shown in the Event Log.

ERROR CODES Errors displayed in the Event Log are as follows:

HARDWARE ERRORS FLASH failure; unable to read or write configuration. FLASH may be damaged. Configuration cannot be accessed or saved. Initialization of interface "lanX" failed. Radio could not be initialized. Possibly a hardware or software failure.

SOFTWARE ERRORS Flow control overflow. This indicates a software bug.

76

Page 87

Flow control underflow. This indicates a software bug. xxxx: file does not exist. Configuration file could not be found. This indicates a software bug.

CONFIGURATION ERRORS xxxx: [yyyy]: section does not exist. Section named yyyy in configuration file named xxxx was missing. xxxx: [ip]: "zzzz": entry refers to non-existant section. Entry zzzz refers to a section that is not located in file xxxx. xxxx: [yyyy]: "zzzz": entry does not exist. Entry zzzz in section yyyy of file xxxx was missing. xxxx: [ip]: "zzzz": entry is invalid. Entry zzzz in section yyyy of file xxxx contains an invalid value. Unable to bring up interface "lanX". Configuration values for the radio may be incorrect. xxxx: <[yyyy]zzzz>: Unable to add route. Route values are out of range compared to the interface values. SCCUART_Restart: Out of buffer memory; efficiency reduced. Buffer allocation values are too high. Values were automatically reduced.

77

Page 88

78

Page 89

APPENDIX E - SPREAD SPECTRUM TECHNOLOGY In 1985, the FCC (Federal Communications Commission) allocated three frequency bands for a radio transmission technique know as Spread Spectrum communications, originally developed by the military. This transmission technique has much greater immunity to interference and noise compared to traditional radio transmission techniques. In addition an increasing number of users can use the same frequency (similar to cellular). In addition, these rules of designed to drive usage towards local data communications. Under the regulations, users of FCC certified Spread Spectrum products do not require a license from the FCC. The only requirement is that the manufacturers of Spread Spectrum products must meet FCC spread spectrum regulations.

INTRODUCTION FCC rule changes in 1985, combined with the continuing evolution of digital technology has catalyzed the development of spread spectrum data communication radios. These radios offer significant performance and operation benefits to end-users. In this section, the operation of spread spectrum radio technology is presented, performance differences between spread spectrum and conventional radios, regulatory implications, and applications are discussed.

CONVENTIONAL RADIO OPERATION For the purposes of this discussion, the term “conventional” will refer to all non-spread spectrum radios. Figure D-1 depicts the radio signal from a conventional radio. This signal is referred to as narrow-band, which means that it contains all of its power in a very narrow portion of the radio frequency bandwidth. Due to the relatively small portion of the radio band that an individual radio transmission occupies, the FCC has traditionally favored these conventional radios. However, as a result of the very narrow frequency, these radios are prone to interference (a single interfering signal at or near their frequency can easily render the radio inoperable).

79

Page 90

RF Power Output

Conventional Radio Signal

Frequency

Figure D-1 Narrow Band Radio Signals

SPREAD SPECTRUM RADIO OPERATION

RF Power Output

Spread spectrum is a technique that takes a narrow band signal and spreads it over a broader portion of the radio frequency band. This has the operational advantage of being resistant it interference, however, due to unfounded concerns over the increased frequency space it occupies, the FCC until recently, did not permit commercial use of the technology.

Spread Spectrum Signal

Frequency

Figure D-2 Spread Spectrum Radio Signal

In performing Spread Spectrum, the transmitter takes the input data and spreads it in a predefined method. Each receiver must understand this predefined method and spread the signal before the data can be interpreted. There are two basic methods to performing the spreading: (1) Frequency Hopping, and (2) Direct Sequencing. Frequency hopping spreads its signals by “hopping” the narrow band signal as a function of time.

80