For the Intermec M90

Page 17

M90 PDE Unit

If the file is sent successfully, the status screen disapĆ pears. If the transmission fails, the following Files" message appears. Click the OK button to exit, then try to send MYPROG.EXE again. Likely problems could include faulty baud rate settings or cable conĆ nections.

6. Press and release [FN] and press " to exit Mode" and return to Mode." 7. Type at the Mode" prompt, then press [ENT SCAN] for a list of files. Ensure that MYPROG.EXE is listed. If listed, go to the next page. If not, go to page 11 to download the program again.

M90 Series Portable Data Entry Unit User’s Guide

13

Page 18

M90 PDE Unit

Review Hyper Terminal Settings

Do the following to change or view Hyper Terminal settings: 1. DoubleĆclick the communications icon (like the one shown left) to access the Terminal" window. 2. From the Terminal" window, select File → Properties to access the window.

3. Change the COM port in the Connect using field and the icon with the Change Icon button. Click the Configure button to access the Properties" window and change the communication port settings. Click the OK button to save your changes or click the Cancel button to exit this screen without saving your changes. 14

M90 Series Portable Data Entry Unit User’s Guide

Page 19

M90 PDE Unit

Operation, General Your M90 PDE unit has more than likely been adapted to suit your specific requirements by programming the M90 PDE unit with an adapted application program. Thus, you have to follow the instructions supplied by your local dealer.

On/Off The M90 PDE unit has no ON/OFF switch. Just press the [S1] and [FN] keys simultaneously to turn the M90 PDE unit on. To turn the M90 PDE unit off, press the [S1] and the [FN] keys simultaneously again. The M90 PDE unit has an automatic off" feature to reduce power drain from the internal main batteries. This function will turn off the unit if no key has been pressed for one to nine minutes (five minutes is default). The automatĆ ic Off" feature can be disabled. NOTE:

Your terminal might be equipped with a customized keyboard and the keys may not correspond to this manual.

Keyboard The keyboard consists of alphanumeric keys. Each key has several functions. By pressing [S1], [S2], or [S3] before pressing a key, the left character, the center character, or the right character above the keys are entered.

Ready Mode After a warm or cold start, the Liquid Crystal Display (LCD) will indicate the following. M90 VerX.XX MEM XXXX KB >

; Model code and version number ; Size of total installed RAM ; Prompt, shows M90 is in “Ready” mode

M90 Series Portable Data Entry Unit User’s Guide

15

Page 20

M90 PDE Unit

User Mode Press and release the [FN] key, then press and release the key in mode to invoke the mode with the following screen displayed: 1. RUN 3. COM 5. ERA 7. CPY NOTE:

2. TER 4. DIR 6. TYP 8. SET

For the “RUN,” “ERA,” and “TYP” commands, use A and " keys to scroll and select another file.

You can use the corresponding number, 1ć8, or use the -, or keys to move the cursor, and then press the [ENT SCAN] key to select a function. RUN TER COM DIR ERA TYP CPY

Runs the highlighted executable program Terminal mode operation Communication function Display M90 disc directory Erase the highlighted file Type the highlighted file Allows you to make a copy of data from a source and transfer to a destination, valid combinations are as follows: Source Destination Description file1 file2 Copy file1 to file2 file1 COM Output content of file1 to serial port file1 CON Output content of file1 to LCD COM file1 Input data from serial port to file1 CON file1 Input data from keyboard to file1, press the [FN] key, release it, then press and release the key to end the data input. SET Set the parameters of the M90 PDE unit To return to the mode, you have to press the [FN] key, release it, then press and release the key. 16

M90 Series Portable Data Entry Unit User’s Guide

Page 21

M90 PDE Unit

Special Keys S1, S2 and S3 The SHIFT keys which allow you to reach the alternate functions above each key. [S1] enables the left function above the keys, [S2] the center, and [S3] the right function. F1, F2, F3, F4, F5, F6, F7 and F8 These keys are application specific keys. Refer to the inĆ structions supplied by your local dealer.

Move to the previous field. - Move to the previous record.

Move to the next record. [S1] + - Moves the cursor to the first record. [S1] + Moves the cursor to the last record. [DEL] Moves the cursor one position left and clears that position. [ENT SCAN] Enters what you have just written to the M90 PDE unit. Or, if in review mode, it moves to the next field, when in a bar code reading field it will activate the laser scanner.

Enter Data Enter data into the M90 PDE unit via any of the following:

Pressing keys on the keyboard. Using the builtĆin bar code scanner or a bar code wand or scanner. Combining keyboard entry with bar code inputs. Downloading data from a host computer. M90 Series Portable Data Entry Unit User’s Guide

17

Page 22

M90 PDE Unit

Key Entry Enter data in response to the display prompts by pressing the appropriate keys. Conclude each data record by pressĆ ing the [ENT SCAN] key.

Bar Code Reader Entry Enter the data in response to the display prompts by pressĆ ing the [ENT SCAN] key and point the scanner beam to the label.

The LED above the display is red as long as the scanĆ ner beam is reading the bar code. When data is accepted, the LED turns green and the M90 PDE unit emits a short beep.

Downloading Data from Host Computer See Downloading from Host Computer on page 6.

Start Application Program To start the application program, you can enter the fileĆ name in the mode or use the RUN command in the mode. The executable program has the extension EXE.

18

M90 Series Portable Data Entry Unit User’s Guide

Page 23

M90 PDE Unit

Battery Replacement Replacing Main Battery Alkaline batteries have to be replaced when the M90 PDE unit displays: ! WARNING ! MAIN BATTERY VOLTAGE LOW or if you see small battery icons to the right of the display. These indicate that the main battery should be replaced in approximately one hour, otherwise, the keyboard will be set in the position (see page 15). These warning will be periodically repeated until the battery is replaced. If the main battery is not replaced, the M90 will be Off and if the backup battery is fullyĆcharged, the data will be safe for two years. If, however, the backup battery is low on power, the data will remain safe for three weeks. If you are using a rechargeable battery, the M90 will have to be charged for approximately for a half hour after the battery low warning occurs. See page 4 for details. WARNING:

Data will be lost if the main battery is exhausted and the backup battery is too low.

Replacing Backup Battery If the M90 displays the following message, the lithium backup battery has to be replaced. See page 5 for details. ! WARNING ! BACKUP BATT. VOLTAGE LOW NOTE:

The main battery must be inserted during replacement of the backup battery. M90 Series Portable Data Entry Unit User’s Guide

19

Page 24

M90 PDE Unit

Battery Life NOTE:

These approximate time periods are estimated for general usage. Your machine and configuration may differ.

Continuous Operation: When data is continuously entered and the display remains on (not communicating).

Alkaline batteries Rechargeable batteries

Five hours Five hours

Normal Daily Use: When data is entered at a normal rate one barcode scan evĆ ery five seconds.

Alkaline batteries

14 hours

Rechargeable batteries 14 hours No Active Use: When the M90 PDE unit is not used or turned off.

Main batteries: Alkaline batteries Rechargeable batteries Backup battery

Two months Two months Two years

When the main battery is removed, the backup battery will preserve the program and data for two years.

20

M90 Series Portable Data Entry Unit User’s Guide