For the Intermec M90

Page 81

SECTION 4

DOS System Call

1F Code 39 Settings Entry Parameter: AH=1FH BH=7 BL=1 AL= Bit 0:

0 1

Bit 1:

0 1

Bit 2: Bit 3:

0 1 0 1

Bit 4: Return Value:

None

0 1

Disable Code 39 decoding Enable Code 39 decoding Disable Check Digit verification Enable Check Digit verification NoĆsend Check Digit Send Check Digit NoĆsend Start/Stop characters Send Start/Stop characters Full ASCII OFF Full ASCII ON

1F Interleaved 2 of 5 Settings Entry Parameter: AH=1FH BH=7 BL=2 AL= Bit 0: 0 Disable I 2 of 5 decoding 1 Enable I 2 of 5 decoding Bit 1: 0 Disable Check Digit verification 1 Enable Check Digit verification Bit 2: 0 NoĆsend Check Digit 1 Send Check Digit Return Value: None

M90 Series Portable Data Entry Unit Reference Manual

4-11

Page 82

DOS System Call

SECTION 4

1F Codabar Settings Entry Parameter: AH=1FH BH=7 BL=3 AL= Bit 0:

0 1

Bit 1:

0 1

Bit 2: Bit 3:

0 1 0 1

Return Value:

None

Disable Codabar decoding Enable Codabar decoding Disable Check Digit verification Enable Check Digit verification NoĆsend Check Digit Send Check Digit NoĆsend Start/Stop characters Send Start/Stop characters

1F Code 128 Setting Entry Parameter: AH=1FH BH=7 BL=5 AL=Bit 0: 0 Disable Code 128 decoding 1 Enable Code 128 decoding Return Value: None 1F EAN 128 Setting Entry Parameter: AH=1FH BH=7 BL=6 AL=Bit 0: 0 Disable EAN 128 decoding 1 Enable EAN 128 decoding Return Value: None

4-12

M90 Series Portable Data Entry Unit Reference Manual

Page 83

SECTION 4

DOS System Call

1F Code 93 Setting Entry Parameter: AH=1FH BH=7 BL=7 AL=Bit 0: 0 Disable Code 93 decoding 1 Enable Code 93 decoding Return Value: None 1F UPC-A Settings Entry Parameter: AH=1FH BH=7 BL=11H AL= Bit 0: Bit 2: Bit 3: Return Value:

None

1F UPC-E Settings Entry parameter: AH=1FH BH=7 BL=12H AL= Bit 0: Bit 2: Bit 3: Bit 4: Return Value:

None

0 1 0 1 0 1

Disable UPC-A decoding Enable UPC-A decoding NoĆsend Check Digit Send Check Digit NoĆsend Leading Digit Send Leading Digit

0 1 0 1 0 1 0 1

Disable UPC-E decoding Enable UPC-E decoding NoĆsend Check Digit Send Check Digit NoĆsend Leading Digit Send Leading Digit Disable Zero Expansion Enable Zero Expansion

M90 Series Portable Data Entry Unit Reference Manual

4-13

Page 84

DOS System Call

SECTION 4

1F EAN-13 Settings Entry Parameter: AH=1FH BH=7 BL=13H AL= Bit 0:

0

0 1 0 1

Disable EAN-13 decoding Enable EAN-13 decoding NoĆsend Check Digit Send Check Digit NoĆsend Leading Digit Send Leading Digit

0 1 0 1

Disable EAN-8 decoding Enable EAN-8 decoding NoĆsend Check Digit Send Check Digit

1 Bit 2: Bit 3: Return Value:

None

1F EAN-8 Settings Entry Parameter: AH=1FH BH=7 BL=14H AL= Bit 0: Bit 2: Return Value:

4-14

None

M90 Series Portable Data Entry Unit Reference Manual

Page 85

SECTION 4

DOS System Call

1F Code 39 Settings Entry parameter: AH=1FH BH=8 BL=1 Return Value: AL=Bit 0: 0 Disable Code 39 decoding 1 Enable Code 39 decoding Bit 1: 0 Disable Check Digit verification 1 Enable Check Digit verification Bit 2: 0 NoĆsend Check Digit 1 Send Check Digit Bit 3: 0 NoĆsend Start/Stop characters 1 Send Start/Stop characters Bit 4: 0 Full ASCII OFF 1 Full ASCII ON 1F Interleaved 2 of 5 Settings Entry Parameter: AH=1FH BH=8 BL=2 Return Value: AL= Bit 0: 0 Disable I 2 of 5 decoding 1 Enable I 2 of 5 decoding Bit 1: 0 Disable Check Digit verification 1 Enable Check Digit verification Bit 2: 0 NoĆsend Check Digit 1 Send Check Digit

M90 Series Portable Data Entry Unit Reference Manual

4-15

Page 86

DOS System Call

SECTION 4

1F Codabar Settings Entry Parameter: AH=1FH BH=8 BL=3 Return Value: AL= Bit 0:

0 1

Bit 1:

0 1

Bit 2: Bit 3:

0 1 0 1

Disable Codabar decoding Enable Codabar decoding Disable Check Digit verification Enable Check Digit verification NoĆsend Check Digit Send Check Digit NoĆsend Start/Stop characters Send Start/Stop characters

1F Code 128 Setting Entry Parameter: AH=1FH BH=8 BL=5 Return Value: AL=Bit 0: 0 Disable Code 128 decoding 1 Enable Code 128 decoding 1F EAN 128 Setting Entry Parameter: AH=1FH BH=8 BL=6 Return Value: AL=Bit 0: 0 Disable EAN 128 decoding 1 Enable EAN 128 decoding 1F Code 93 Setting Entry Parameter: AH=1FH BH=8 BL=7 Return Value: AL=Bit 0: 0 Disable Code 93 decoding 1 Enable Code 93 decoding 4-16

M90 Series Portable Data Entry Unit Reference Manual

Page 87

SECTION 4

DOS System Call

1F UPC-A Settings Entry Parameter: AH=1FH BH=8 BL=11H Return Value: AL= Bit 0: Bit 2: Bit 3: 1F UPC-E Settings Entry parameter: AH=1FH BH=8 BL=12H Return Value: AL= Bit 0: Bit 2: Bit 3: Bit 4: 1F EAN-13 Settings Entry Parameter: AH=1FH BH=8 BL=13H Return Value: AL= Bit 0:

0 1 0 1 0 1

Disable UPC-A decoding Enable UPC-A decoding NoĆsend Check Digit Send Check Digit NoĆsend Leading Digit Send Leading Digit

0 1 0 1 0 1 0 1

Disable UPC-E decoding Enable UPC-E decoding NoĆsend Check Digit Send Check Digit NoĆsend Leading Digit Send Leading Digit Disable Zero Expansion Enable Zero Expansion

0

Disable EAN-13 decoding Enable EAN-13 decoding NoĆsend Check Digit Send Check Digit NoĆsend Leading Digit Send Leading Digit

1 Bit 2: Bit 3:

0 1 0 1

M90 Series Portable Data Entry Unit Reference Manual

4-17

Page 88

DOS System Call

SECTION 4

1F EAN-8 Settings Entry Parameter: AH=1FH BH=8 BL=14H Return Value: AL= Bit 0: Bit 2:

0 1 0 1

Disable EAN-8 decoding Enable EAN-8 decoding NoĆsend Check Digit Send Check Digit

25 Set Interrupt Vector Entry Parameter: AH=0x25 AL=Interrupt number DS:DX=Address of interrupt routine Return Value: None 2A Get System Date Entry Parameter: AH=0x2A Return Value: CX=Year (1980 through 2079) DH=Month (1ć12) DL=Day (1ć31) AL=Day of week (0ć6) 2B Set System Date Entry Parameter: AH=0x2B CX=Year (1980 through 2079) DH=Month (1ć12) DL=Day (1ć31) Return Value: AL=0 OK AL=FFH Input parameter error 2C Get System Time Entry Parameter: AH=0x2C Return Value: CH=Hour (0ć23) CL=Minutes (0ć59) DH=Seconds (0ć59) DL=1/100th of a second (0ć99)

4-18

M90 Series Portable Data Entry Unit Reference Manual

Page 89

SECTION 4

DOS System Call

2D Set System Time Entry Parameter: AH=0x2D CH=Hour (0ć23) CL=Minutes (0ć59) DH =Seconds (0ć59) Return Value: AL=0 OK AL=FFH Input parameter error 2E Set Alarm Date Entry Parameter: AH=0x2E AL=0 Disable alarm AL=1 Enable Every Day/Time type alarm AL=2 Enable Specific Date/Time type alarm If AL=2 CX=Year (1980 through 2079) DH=Month (1ć12) Dl=Day (1ć31) Return Value: AL=0 OK AL=FFH Setting error 2F Set Alarm Time Entry Parameter: AH=0x2F CH=Hour (0ć23) CL=Minutes (0ć59) DH=Seconds (0ć59) Return Value: AL=0 OK AL=FFH Input parameter error 30 Get M90 DOS Version Number Entry Parameter: AH=0x30 Return Value: AL=2 AH=0 CL=Major firmware version number CH=Minor firmware version number

M90 Series Portable Data Entry Unit Reference Manual

4-19

Page 90

DOS System Call

" NOTE:

SECTION 4

“Major” indicates the prefix in the version number and “Minor” indicates the suffix in the version number (i.e. “.YY”). For example, “X.YY” has “X” for the major version number and “YY” for the minor version number.

35 Get Interrupt Vector Entry Parameter: AH=0x35 AL=Interrupt number Return Value: ES:BX=Address of interrupt routine 36 Get Free Disk Cluster Entry Parameter: AH=0x36 Return Value: AX=1 (Number of sectors per cluster) BX=Number of available clusters CX=1024 (Number of bytes per sector) DX=Number of total clusters in RAM disk 37 Set EXEC Memory Size Entry Parameter: AH=0x37 AL=0 DX=size in KB 1-488 Return Value: AL=0 OK AL=1 Error 37 Get EXEC Memory Size Entry Parameter: AH=0x37 AL=1 Return Value: AX=Current EXEC memory size in KB CX=Maximum KB EXEC memory size

4-20

M90 Series Portable Data Entry Unit Reference Manual