For the Intermec M90
Page 111
SECTION 4
" NOTE:
DOS System Call
The following function does not check system input-data buffers. It waits for interrupts and new input data. M90 shuts off according to system settings if there is no data input during the auto-off time period.
2 Wait Interrupt - Input Data with Buffer Check Entry Parameter: AH=2 Return Value: AL=(bit sets) Bit 0: Keypad Bit 1: Scanner Bit 2: RS-232 receiver Bit 3: Other or userĆdefined interrupts Bit 4: PowerĆon " NOTE:
If there is input data in the system buffers, the function returns directly. Otherwise, it waits for interrupts and new input data. M90 shuts off according to system settings if there is no data input during the auto-off time period.
3 Wait Interrupt - Input Data with Timeout Entry Parameter: AH=3 CX=Timeout 10-30,000 ms Return Value: AL=0 Keypad AL=1 Scanner AL=2 RS-232 receiver AL=3 Other or userĆdefined interrupts AL=4 PowerĆon AL=5 Timeout
M90 Series Portable Data Entry Unit Reference Manual
4-41
Page 112
DOS System Call
" NOTE:
SECTION 4
The Wait Interrupt – Input Data with Buffer Check and Timeout function does not check system input data buffers. If there is input data in the system buffers, the function returns directly. Otherwise, it waits for interrupts and new input data. M90 will not turn off according to system settings.
4 Wait Interrupt Ċ Input Data with Buffer Check and Timeout Entry Parameter: AH=4 CX=Timeout 10-30,000 ms Return Value: AL=(bit sets) Bit 0: Keypad Bit 1: Scanner Bit 2: RS-232 receiver Bit 3: Other or userĆdefined interrupts Bit 4: PowerĆon
Beeper Frequency and Time Control: INT 31H Entry Parameter: AX=Frequency BX=Time duration Return Value: None Note:
4-42
AX 0 1 2 3 4 5 6 7 8
Frequency(Hz) BX 200 0 400 1 600 2 800 3 1K 4 2K 5 2.5K 6 3K 7 5K 8
M90 Series Portable Data Entry Unit Reference Manual
Time Duration 10 ms 50 ms 100 ms 200 ms 500 ms 800 ms 1 second 1.5 seconds 2 seconds
Page 113
SECTION 4
DOS System Call
Table 4-6 Implemented BIOS Functions (INT 31h) Function
Description
Comment
(Not applicable)
Beeper frequency and Time Control
Added function
RS-232 Function: INT 33H 0 Set Communication Parameters Entry Parameter: AH=0 AL Bits 7ć4: 0001xxxx Baud 150 0010xxxx Baud 300 0011xxxx Baud 600 0100xxxx Baud 1200 0101xxxx Baud 2400 0110xxxx Baud 4800 0111xxxx Baud 9600 1000xxxx Baud 19200 1001xxxx Baud 38400 1010xxxx Baud 57600 Bits 3ć2: xxxx00xx No parity xxxx01xx Odd parity xxxx11xx Even parity Bit 1: xxxxxx0x One stop bit xxxxxx1x Two stop bits Bit 0: xxxxxxx0 7 data bits xxxxxxx1 8 data bits Return Value: None 1 Input Character Entry Parameter: AH=1 Return Value: If no character received: AH=1 AL=Unpredictable If a character received: AH=0 AL=Character input M90 Series Portable Data Entry Unit Reference Manual
4-43
Page 114
DOS System Call
SECTION 4
2 Output Character Entry Parameter: AH=2 AL=Character output Return Value: None 3 Enable RS-232 Port Entry Parameter: AH=3 Return Value: None 4 Disable RS-232 Port Entry Parameter: AH=4 Return Value: None 5 Set RTS/DTR Entry Parameter: AH=5 AL= Bit 0: Bit 1: Return Value:
None
0 1 0 1
Set RTS low level Set RTS high level Set DTR low level Set DTR high level
6 Get RS-232 Hardware Status Entry Parameter: AH=6 Return Value: AL= Bit 0: 0 Get RTS low level 1 Get RTS high level Bit 1: 0 Get DTR low level 1 Get DTR high level Bit 2: 0 Get OUT0 low level 1 Get OUT0 high level Bit 3: 0 Get CTS low level 1 Get CTS high level Bit 4: 0 Get DSR low level 1 Get DSR high level Bit 5: 0 Get RI low level 1 Get RI high level Bit 6: 0 Get DCD low level 1 Get DCD high level
4-44
M90 Series Portable Data Entry Unit Reference Manual
Page 115
SECTION 4
" NOTE:
DOS System Call
Bits 4, 5, and 6 (DSR, RI, and DCD) are returning the same value as RI. If Function 6 is called when the M90 is in an office dock, RI is the only signal present in the connector. If the M90 is connected via the direct connect cable, all of those bits are undefined as neither signal is present in the Modular connector at the bottom of the M90.
7 Set OUT0 Signal Entry Parameter: AH=7 AL=0 AL=1 Return Value:
None
Set OUT0 signal in Modular 10Ćpin connector to low Set OUT0 signal in Modular 10Ćpin connector to high
Table 4-7 Implemented BIOS Functions (INT 33h) Function Description
Comment
00h
Set Communication Parameters
Added function
01h
Input RS-232 character
Added function
02h
Output RS-232 character
Added function
03h
Enable RS-232 port
Added function
04h
Disable RS-232 port
Added function
05h
Set RTS/DTR
Added function
06h
Get RS-232 hardware status
Added function
07h
Set OUT0 signal in Modular 10Ćpin connector
Added function
M90 Series Portable Data Entry Unit Reference Manual
4-45
Page 116
DOS System Call
4-46
M90 Series Portable Data Entry Unit Reference Manual
SECTION 4
Page 117
Appendix A
Connector Pin Assignments "
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
Table A-1 10-Pin Modular Connector Pin # Signal
Direction Description
1
DC 9 V
Power
9Ćvolt charge power
2
TXD
Output
Transmitted Data
3
RXD
Input
Receive Data
4
I/O 5 V
Power
Regulated 5Ćvolt max 100 mA
5
GND
Power
Ground
6
DTR
Output
Data Terminal Ready
7
CTS
Input
Clear to Send
8
RTS
Output
Request to Send
9
WANDSIG1
Input
Wand input
10
OUT0
Output
Digital OUT0 signal
M90 Series Portable Data Entry Unit Reference Manual
A-1
Page 118
Connector Pin Assignments
A-2
M90 Series Portable Data Entry Unit Reference Manual
APPENDIX A
Page 119
Appendix B
Programming Applications "
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
The M90 provides a utility for putting application programs into the system Read-Only Memory (ROM) area. Once in the ROM, the programs become userĆresident applications in the M90 system. The advantage of the userĆresident apĆ plication is that they do not have to be downloaded from a host computer through M90 RS-232 port and cannot be acĆ cidentally deleted. It can also save the Random Access Memory (RAM) space for the system. Up to eight userĆresiĆ dent applications can be in the M90, with the total file size less than or equal to 128 KB. The M90 system EXEC job scheduler supports the userĆresĆ ident application. The ROM resident user applications must be of *.EXE type. The system does not allow data files. EXEC searches userĆresident applications first when a RUN command executes. If there is an AUTOEXEC.EXE userĆresident application, it runs after powerĆon when the M90 is in Mode." To add a program to the ROM disk, download the program to the RAM disk as described later in this appendix, then start the M90 in the Mode." Select System → Programming → Add Program. Adding a program is fully described under Modes" in Section 3. " NOTE:
As this requires reprogramming of the FLASH in the M90, make sure that either the M90 battery is fully charged or that the M90 is on charge (office dock). A power failure during flash programming could corrupt the FLASH. If this occurs, you must have the M90 FLASH EEPROM replaced at a service center. M90 Series Portable Data Entry Unit Reference Manual
B-1
Page 120
Programming Applications
APPENDIX B
Reprogramming the M90 Flash The following steps explain how to update the existing flash program in the M90. The M90 Flash can be updated to a new version. Download the new flash to the M90 RAM disk, then start the M90 in Mode." Select System → ProĆ gramming → Update Flash (see Modes" in Section 3). " NOTE:
As this requires reprogramming of the FLASH in the M90, make sure that either the M90 battery is fully charged or that the M90 is on charge (office dock). A power failure during flash programming could corrupt the FLASH. If this occurs, the M90 has to have the FLASH EEPROM replaced at a service center.
Download Application or BIOS to M90 Set Up M90 Downloading from Host Computer Connect the host personal computer (PC) to the M90 unit with a serial null modem cable. Select in the Mode" and the M90 enters the server" mode with default communication parameters 19200 bps, 8 bit, 1 stop, no parity, and no flow control.
Kermit Communications Program To set up the PC to talk to the M90 unit using a Kermit communications program, consult your manual for the KerĆ mit communications program.
B-2
M90 Series Portable Data Entry Unit Reference Manual