Page 51

code3 nuggCustomizing Your Configuration

3

Keypad Mode VT series terminals have two modes for function keys, editing keys, and numeric keys: Application mode and Numeric mode. These keys generate different key codes depending on the mode your VT terminal is using. The default is Numeric mode. If you select Numeric mode, you generate ANSI cursor control ESC sequences that correspond to what appears on the face of the keys. If you select Application mode, you generate application ESC sequences for the key code. For more information, see Appendix B, “VT/ANSI Keyboard Remapping.” Cursor Mode VT series terminals have two modes for arrow keys: Application mode and Cursor mode. These keys generate different key codes depending on the mode your terminal is using. The default is Cursor mode. Numeric Keypad You can use this field to enable or disable Numeric Keypad mode on the JANUS device. The default is disable. When you enable Numeric Keypad mode, numeric keys function like the numeric keys on the numeric keypad. When you disable Numeric Keypad mode, numeric keys function like the numeric keys on the main keyboard. Input Mode

Options are Line mode or Character mode.

@

If you select Line mode, you enter a line of characters on your JANUS device and press before it is transferred to the host. In Line mode, communications overhead is reduced because input is sent one line at a time instead of one or a few characters at a time. If you select Character mode, each character you type is immediately sent to the host. Protocol UDP Plus only. Toggles between 0200R1, standard, and enhanced. You must use the 0200R1 protocol if you want your JANUS device to communicate with the Model 200 Controller. Answerback The answerback string is sent from a connected JANUS device to the host in response to an ENQ from the host or as a key sequence from the user. This field can be up to 30 characters in length. Any ASCII character from 0 to 255 can be entered as part of the answerback string. A carriage return can be placed anywhere in the Answerback field. Enter the following four characters for a carriage return: <cr>.

3-11

Page 52

JANUS 2.4 GHz Terminal Emulation Quick Reference Guide code2 nugg

Communications Host Name Enter the name of the host to which you want the JANUS device to connect. The host name can be up to 15 characters in length and can be the IP address of the host instead of the host name. Note: If you have linked a device with a host name on the controller, you do not need to enter a host name on this screen. If you have not linked a device with a host name on the controller, you must enter a host name for this parameter. The host name on this screen must match a host name in the list of available hosts defined on the controller.

Viewport Viewport Mode Specifies one of the following viewport movement modes: •

Follow enables Viewport Follow Cursor mode.

•

Manual disables Viewport movement.

Side Boundary (Follow mode) Controls side movement of the viewport. The viewport moves when the cursor is the specified number of characters from the side boundary. Options are 1 to 10 characters. The default is 6 characters. Side Jump (Follow mode) Specifies the number of characters the viewport moves in a horizontal direction. Options are 1 to 10 characters. The default is 10 characters. Vertical Boundary (Follow mode) Moves the viewport when the cursor is the specified number of characters from the vertical viewport boundary. Options are 1 to 10 characters. The default is 1 character. Vertical Jump (Follow mode) The JANUS device uses this parameter to control vertical movement of the viewport. Options are 1 to 10 characters. The default is 8 characters.

Permanently Changing Your Configuration You can modify the contents of drive C or drive D (the RAMDRIVE) before the drive images are built by using the shell out switch (/s) when you start the installation utility. You will exit to the DOS command line before the utility builds the drive images. Using DOS commands or a DOS editor, you can then add, delete, or change files. Refer to the JANUS 2.4 GHz Installation Utility User’s Manual for more information on modifying files during the TE installation procedure.

3-12

Page 53

code3 nuggCustomizing Your Configuration

3

Setting Security for the Configuration Application The following section describes how to set a password to allow access to the configuration application.

Setting Security For UDP Plus 3270, 5250, and VT/ANSI You can set a password to control access to the terminal emulation configuration application. When a TE password is enabled, the Verify TE Password screen appears when you use a hot key ( for 3270 and 5250 or for VT/ANSI) to access the configuration application.

>-

<7

A TE password can be a maximum of 10 characters in length and is stored in an encrypted form in the TE.SEC file. A password that you set on the device using the TE configuration feature is only valid for the current TE session. When you reconnect to the host through the Model 200 Controller, the permanent password stored on the Model 200 Controller is again downloaded to the connected device and overwrites TE.SEC. Note: The TE.SEC file should be stored on the E drive and NOT on the C drive. Intermec recommends that you keep a backup encrypted TE.SEC file on the C drive in case the E drive version is lost or damaged. To enable or disable the UDP Plus password

<7 >- 2. Use the : or U to highlight Set Password and press @. 3. Enter information on the Set TE Password screen then Select OK and press @. 1. Press (3270 or 5250) or (VT/ANSI) to access the TE configuration application.

Old Password This field is for password verification purposes. Asterisks representing the password are displayed on the screen. An error message, “Incorrect Old Password Entry” appears if the data you enter does not match the original password.

3-13

Page 54

JANUS 2.4 GHz Terminal Emulation Quick Reference Guide code2 nugg

Note: Leave this field blank if no password is configured. New Password Type the new password in this field. Asterisks are displayed in the field for each keystroke you enter in this field. To disable the security feature, leave this field blank. Verify Password Type the new password again to verify that it was entered correctly. Asterisks are displayed for keystrokes in this field. Note: To remove an existing password, enter the current password in the Old Password field and leave the New Password and Verify Password fields blank. Choose OK to remove password protection. and press

@

4. After you set a password, the Verify TE Password screen is displayed when you attempt to access the TE configuration application. Type the password and press to proceed.

@

Setting Security for TN3270 and TN5250 TE Use the Telnet Configuration Menu to establish or change security settings for devices configured for Telnet 3270 or 5250 terminal emulation. You can only set security for Telnet TE on the JANUS device. Drive E is the default storage location for the password. It is recommended that you store a default encrypted password on drive C as a backup. When you run the installation utility to configure your device, you should include the default TE.SEC security file when you build a drive C image. You can also put a copy of the TE.SEC file on drive E so that it can be changed easily, otherwise you will need to upload the drive, modify TE.SEC, and download a new drive image on the device. For more information on setting security for Telnet 3270 and 5250 terminal emulation, see “Changing Telnet 3270 and 5250 Session Options” earlier in this chapter.

3-14

Page 55

code3 nuggCustomizing Your Configuration

3

Setting Security for Telnet VT/ANSI You can set a password to control access to the terminal emulation configuration application. When a TE password is enabled, the Verify TE Password screen appears when you use a hot key ( ) to access the configuration application.

>-

To enable or disable the Telnet VT/ANSI password

>-

1. Press to access the TE configuration application.

@

2. Use the .

: or U to highlight Set Password and press @

3. Enter information on the Set TE Password screen then Select OK and press . Old Password This field is for password verification purposes. Asterisks representing the password are displayed on the screen. An error message, “Incorrect Old Password Entry” appears if the data you enter does not match the original password. Note: Leave this field blank if no password is configured. New Password Type the new password in this field. Asterisks are displayed in the field for each keystroke you enter in this field. To disable the security feature, leave this field blank. Verify Password Type the new password again to verify that it was entered correctly. Asterisks are displayed for keystrokes in this field. Note: To remove an existing password, enter the current password in the Old Password field and leave the New Password and Verify Password fields blank. Choose OK to remove password protection. and press

@

3-15

Page 56

JANUS 2.4 GHz Terminal Emulation Quick Reference Guide code2 nugg

Using the Auto-Login Feature The TE auto-login feature is invoked at TE startup when an auto-login script is detected. The script file, AUTOLOG.SCR must be stored in the application startup directory. Auto-login information is lost when you reboot your JANUS device. In addition, processing of the auto-login script is terminated if you press any key during the auto-login sequence. The Auto-Login Restart commands ( for 3270/5250 or for VT/ANSI) allow you to restart the auto-login sequence when a host session is broken. For more information on the Auto-Login Restart commands, see Chapter 4, “3270 and 5250 Commands,” or Chapter 5, “VT/ANSI Commands.”

IMPORTANT! Auto-login information is saved when you end a TE session by logging off from the host computer. This DOES NOT prevent another user from establishing a TE session using your login information. You must exit the terminal emulation application to purge auto-login information.

Developing Auto-Login Scripts A typical auto-login script consists of a few Input and InputHidden commands followed by a HostName command, followed by a series of WaitFor and Send commands. A very simple script may not have any input commands if all of the JANUS devices are using the same account. There are six commands you can use to create auto-login scripts. All commands are case sensitive. For example, WaitFor is a command but Waitfor is not a valid command. For more information on auto-login scripts, see “Sample AutoLogin Scripts” in Appendix A.

Auto-Login Script Commands Auto-login script commands are defined below: Input Input is called with two parameters. The first parameter is a quoted string that is used as a prompt to the user. The second parameter is a string variable name indicating where the text string will be stored. InputHidden Same as the Input script command except that user input is echoed as a string of asterisks. HostName HostName is followed by a quoted string. The quoted string can be a host name or an asterisk. The host name command acts as an IF clause. If the host name matches, the following section of the script is executed up to the next host name command. If an asterisk is used, it matches any host name. WaitFor Wait for a list of up to 10 strings. The strings must be quotes and must be separated by a comma. The strings cannot exceed 20 characters in length.

3-16

Page 57

code3 nuggCustomizing Your Configuration

3

Send This command sends a quoted string or string variable to the host. The quoted string can have an embedded control key in VT/ANSI emulation and embedded IBM mnemonics in 3270 and 5250 emulation. PromptSessionStart PromptSessionStart is a predefined variable. If this variable is defined and set to any value other than 0, TE prompts the user to press before starting a Telnet session with the host.

@

Control Characters for Auto-Login Scripts You can also include control characters in your auto-login script. The control character must be enclosed by < > in the AUTOLOG.SCR file. Note: For VT/ANSI terminal emulation, you can also use the corresponding hexadecimal value to represent the control character. For a description of control characters and their hexadecimal equivalents, see the “Full ASCII Table” in your JANUS user’s manual.

3270/5250 Control Characters Control Character

Definition

Control Character

Definition

Control Character

Definition

<ATTN>

Attention

<RTAB>

Right Tab

<F12>

Function Key

<CLEAR>

Clear

<SPACE>

Space

<F13>

Function Key

<CUR_DN>

Cursor Down

<F1>

Function Key

<F14>

Function Key

<CUR_LF>

Cursor Left

<F2>

Function Key

<F15>

Function Key

<CUR_RT>

Cursor Right

<F3>

Function Key

<F16>

Function Key

<CUR_UP>

Cursor Up

<F4>

Function Key

<F17>

Function Key

<DEL>

Delete

<F5>

Function Key

<F18>

Function Key

<ERS_EOF>

Erase EOF

<F6>

Function Key

<F19>

Function Key

<HOME>

Home

<F7>

Function Key

<F20>

Function Key

<INS>

Insert

<F8>

Function Key

<F21>

Function Key

<LTAB>

Left Tab

<F9>

Function Key

<F22>

Function Key

<NEWLN>

New Line

<F10>

Function Key

<F23>

Function Key

<RESET>

Reset

<F11>

Function Key

<F24>

Function Key

3-17

Page 58

JANUS 2.4 GHz Terminal Emulation Quick Reference Guide code2 nugg

VT/ANSI Control Characters Control Character

Definition

Control Character

Definition

Control Character

Definition

<ACK>

Acknowledgment

<ENQ>

Enquiry

<NUL>

Null, or all zeroes

<BEL>

Bell

<EOT>

End of Transmission

<RS>

Record Separator

<BS>

Backspace

<ESC>

Escape

<SI>

Shift In

<CAN>

Cancel

<ETB>

End Transmission Block

<SO>

Shift Out

<CR>

Carriage Return

<ETX>

End of Text

<SOH>

Start of Heading

<DC1>

Device Control 1 (XON)

<FF>

Form Feed

<STX>

Start of Text

<DC2>

Device Control 2

<FS>

File Separator

<SUB>

Substitute

<DC3>

Device Control 3 (XOFF)

<GS>

Group Separator

<SYN>

Synchronous Idle

<DC4>

Device Control

<HT>

Horizontal Tab

<US>

Unit Separator

<DLE>

Data Link Escape

<LF>

Line Feed

<VT>

Vertical Tab

<EM>

End of Medium

<NAK>

Negative Acknowledge

Loading the Auto-Login File Create your auto-login file using any text editor or copy and modify one of the example scripts in Appendix A. Save the file you create as AUTOLOG.SCR. You must load the AUTOLOG.SCR file in the same directory as the TE application. Refer to your JANUS user’s manual for information about creating drive images and loading the drive image on your JANUS device.

3-18

Page 59

code3 nuggCustomizing Your Configuration

3

Configuring Terminal Emulation to Display International Characters You can configure your JANUS 2.4 GHz terminal emulation device to display single byte international characters. In order to use international character sets, you must configure the device to load Code Page 850. Shell out to DOS when you are running the Installation Utility and add the appropriate files to the drive images you are building. Copy the appropriate files to C:\IMFLASH\DRIVEC\DISPTBLS.MAP. Note: International character maps for 3270 and 5250 TE are stored in the USERDATA\TERMAPPS\IBMTE directory on the Model 200 Controller. International character maps for VT/ANSI TE are stored in the USERDATA\TERMAPPS\VTTE directory. Character maps are also provided on the TE application disk

IBM 3270 and 5250 Code Pages Country

Code Page

File

Other Countries

U. S. English

37

037-850.MAP

Canada

Germany

273

273-850.MAP

Norway

277

277-850.MAP

Denmark

Sweden

278

278-850.MAP

Finland

Italy

280

280-850.MAP

Spain

284

284-850.MAP

France

297

297-850.MAP

Portugal

500

500-850.MAP

Belgium, Brazil, Switzerland

VT/ANSI Code Pages To use a custom translation table for VT/ANSI terminal emulation, make a copy of ISO1-850.MAP (for UNIX hosts) or DEC-850.MAP (for DEC/VAX hosts) and copy the file to DISPTBLS.MAP on the JANUS device. Character Set

File

ISO8859-1

ISO1-850.MAP

DEC Multinational

DEC-850.MAP

3-19

Page 60

JANUS 2.4 GHz Terminal Emulation Quick Reference Guidecode2 nugg

AUTOEXEC.BAT and CONFIG.SYS Changes After installing the correct code page table, you will also need to make modifications to the CONFIG.SYS and AUTOEXEC.BAT files on the JANUS device to load the correct Code Page and display the international characters. The CONFIG.SYS change sets up the display system to use Code Page 850. The AUTOEXEC.BAT change selects Code Page 850 for the display. Lines added to CONFIG.SYS DEVICE=D:\DISPLAY.SYS CON=(LCD,437,1)

Lines added to AUTOEXEC.BAT D: MODE CON CP PREP=((850)D:\LCD.CPI) MODE CON CP SELECT=850 NLSFUNC CHCP 850

3-20