Page 11

D>JIcode Before You Begin Format Conventions for Bar Codes You can scan the bar codes listed in this manual to enter data or perform a command. The bar code labels in this manual are printed in the Code 39 symbology. Each bar code includes the name and human-readable interpretation. For example:

Change Configuration

Name

*$+*

Bar code (Code 39) Human-readable interpretation

*$+*

2010U.073

The asterisks (*) at the beginning and end of the human-readable interpretation are the start and stop codes for a Code 39 bar code label. If you are creating bar code labels with a bar code utility, it may automatically supply the asterisks as the start and stop code, so that you only need to type the actual text of the command. You can also create and print configuration labels and reader command labels in Code 93, which has its own start and stop codes.

Other Related Manuals You may need to refer to other manuals when working with JANUS 2.4 GHz terminal emulation software. To order additional manuals, contact your local Intermec representative. Intermec Manuals

Intermec Part No.

0110 Access Point User’s Manual

065053

Model 200 Controller System Manual

063439

JANUS 2010 Hand-Held Computer User’s Manual (4MB)

065714

JANUS 2020 Hand-Held Computer User’s Manual (4MB)

065715

JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB)

065716

JANUS 2.4 GHz Installation Utility User’s Manual (4MB)

064673

Other Manuals Intermec recommends that 5250 users obtain a copy of the IBM 5494 Remote Control Unit Functions Reference Manual for more detailed information regarding 5250 commands, local editing functions, and error messages.

xi

Page 12

This page is a scan with no text; see it in the PDF.

Page 13

1 Getting Started

Page 14

This page is a scan with no text; see it in the PDF.

Page 15

nuggcd39 Getting Started

1

This chapter provides basic information for setting up and using your JANUS data collection computer with 2.4 GHz terminal emulation software.

Introduction JANUS 2.4 GHz terminal emulation (TE) runs on the industry standard TCP/IP protocol and Intermec’s UDP Plus protocol. Both protocols provide reliable data transfer between a host computer and your JANUS 2.4 GHz RF device, which functions as a computer terminal. Intermec TE software can emulate the following types of terminals: •

VT100/220/320 and ANSI

•

IBM 3270

•

IBM 5250

In addition to the software shipped with all JANUS devices, your JANUS TE device contains a special keypad and software that provides most of the commands available for the supported terminals. You can use your JANUS TE device to: •

View terminal screens on your JANUS display.

•

Enter data into the screens using the scanner or keypad.

•

Access host commands and perform host functions.

•

Automatically transmit the data to the host.

Other features of your JANUS TE device include: •

Auto-login capability.

•

Password security.

•

Choice of SNA or TCP/IP (Telnet) protocols for IBM terminal emulation.

•

5250 Field Advance configuration.

•

Support for display of single byte international character sets.

The terminal emulation disk contains a README.DOC file. This file may contain information about the product that was not available when this manual was published. You can view or print this file with any text editor.

1-3

Page 16

JANUS 2.4 GHz Terminal Emulation Quick Reference Guidenuggcd39

Installing Terminal Emulation Software Refer to the JANUS 2.4 GHz Installation Utility User’s Manual (4MB), Part Number 064673, for detailed information on installing terminal emulation software and configuring your JANUS 2.4 GHz RF device. The JANUS 2.4 GHz installation utility user’s manual is included with your installation kit. After terminal emulation software is installed, Intermec recommends that you issue a PING command to the IP address of your newly installed JANUS TE device. The PING command usually runs until you interrupt it with Ctrl-C or an equivalent command. A response to PING indicates that the new IP address is alive. The times reported by PING are the approximate times it took for each message to reach another address or host and come back, measured in milliseconds. Note: If you have problems establishing a connection with an ANSI terminal on a UNIX system, you may need to install the Intermec RDR ANSI terminfo file on your system. RDR ANSI is a terminal information database file that contains escape sequences associated with ANSI terminal keystrokes. Contact Intermec Technical Support for additional information or a copy of the RDR ANSI terminfo file.

1-4

Page 17

nuggcd39 Getting Started

1

System Connectivity Options The following two diagrams illustrate your system connectivity options. The host side of terminal emulation is provided through a Telnet Session Manager for the TCP/IP protocol stack, and an SNA session manager residing on the Model 200 Controller for 3270 or 5250 UDP Plus clients. The Direct Host Connection option has one or more host computers communicating with one or more access points spread on an Ethernet network. The access points in turn communicate with JANUS 2.4 GHz devices running terminal emulation software.

Direct Host Connection Host

• Telnet

Ethernet

Access point

JANUS devices 2-4TEQ.004

1-5

Page 18

JANUS 2.4 GHz Terminal Emulation Quick Reference Guidenuggcd39

With the Model 200 Controller connection, one or more host computers are communicating with a Model 200 Controller, which in turn communicates with one or more access points on separate Ethernet networks.

Model 200 Controller Connection Host • Telnet • SNA

Ethernet, Token Ring Model 200 Controller

Ethernet

Access point

JANUS devices 2-4TEQ.003

1-6

Page 19

nuggcd39 Getting Started

1

Starting Telnet Terminal Emulation Before you can begin using your JANUS device with terminal emulation software as a terminal, you must start the terminal emulation program. You only need to start the program the first time you use it or if you exit. The JANUS device resumes terminal emulation for each data collection session. To start terminal emulation 1. Type RWSTR at the DOS prompt on your JANUS device and press @ . You can then start a TE session by issuing one of the following commands from the DOS prompt. You need to run NET.BAT before using these TE commands. Terminal Type

TE Command

Optional Parameters

3270

TN3270 [hostname] hostname is the host IP address or host name. If you use the host name, then you must install a HOSTS file on drive C of the JANUS device. For more information on creating a HOSTS file, see “Creating a HOSTS File” in Chapter 2 of the JANUS 2.4 GHz Installation Utility User’s Manual.

5250

TN5250 [hostname]

VT100/220/320 and ANSI

TNVT.EXE [hostname]

Note: You must have TN3270.EXE and JAN3270.MAP or TN5250.EXE and JAN5250.MAP files located in the same directory before you can use the TN3270 and TN5250 commands.

1-7

Page 20

JANUS 2.4 GHz Terminal Emulation Quick Reference Guidenuggcd39

2. Wait a few seconds while the display clears and the terminal emulation program starts. Once the display on the JANUS device shows the Sign on screen, you are ready to use your device as a terminal.

Sign on

User................. Password............. Program/procedure.... Menu................. Current library......

TNAPP

F

2-4TEQ.006

Exiting Telnet Terminal Emulation If you want to use your JANUS device as a personal computer, you must exit the terminal emulation program. Pressing the L button does not exit terminal emulation, instead it toggles the JANUS device between an operating state and a suspend state. Once you have started terminal emulation, your JANUS device resumes the terminal emulation program every time you press L and switch it to an operating state. To exit 3270 and 5250 terminal emulation 1. Press < 7 to access the TE Configuration Menu. 2. Press 0 @ to close the current connection and exit to DOS. To exit VT and ANSI terminal emulation 1. Press > I to access the Exit Menu. 2. Highlight the Exit TE option and press @ . Or, Press > K to exit terminal emulation directly.

1-8