The text of a manual · part 6 of 42
JANUS 2050 Vehicle-Mount Computer (4MB) User's Manual, pages 51 to 60
Pages 51 to 60 of 419
The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec J2050
Page 51
JANUS 2050 Vehicle Mount Computer User’s Manual (4MB)39 nugget A Italian Keypad TM
I/O
F6 Conn
F1
Data F7
F2
Ctrl
Alt
Shift
Maius
F8
F3 F9
F4 f F10
F5
?
A '
\
G °
H
M
I
N T
[ +
J ;
O U
K
P
@
L
Q
-
R
4 fine !
-
W
7
$
_
.
V
/
F ] ò
:
,
<
E
X
1
Z
Ctrl
Alt
(
* %
8 5 invio .
2 ins
Maius
Y pag
+
Ç
*
D è
>
# ù
S
C '
§
à
é
^
B f
= space
)
/ &
9 6 pag £
3 bloc num canc
0
Esc
.
invio
2050U.048
2-12
Page 52
39 nugget A Operating the JANUS 2050
2
Spanish Keypad TM
I/O
F6 Conn
F1
Data F7
Ctrl
F2
Alt F8
Shift
F3
Bloq mayus
F9
F4 f F10
F5
?
°
A -
`
G
Ü
˙
B
C [
=
H
*
D
I
J
M
N
O
S
T
U
K >
P ,
\
' home
+
&
*
7
-
Q
Z
Ctrl
Alt
(
9
/
R end enter pg dn
!
@
#
4
X
1
Caps
Y
8
$
/
W
* % pg up
L ?
.
V
F ;
]
<
"
:
E f space
5 2
^ ins del
)
>
0
6 3
Esc num lock
.
enter
2050U.047
2-13
Page 53
JANUS 2050 Vehicle Mount Computer User’s Manual (4MB)39 nugget A
Terminal Emulation (TE) Keypads A JANUS 2050 configured for terminal emulation comes with a keypad that contains most of the keys available on an IBM 3270 or 5250 keyboard. The TE keypads are similar to the regular JANUS 2050 keypads, but have additional commands that are specific to IBM 3270 or 5250 systems. The following illustration shows the 3270 and 5250 keypads.
~
F13
_
A sysrq
\
[
|
F17
<
]
,
> attn
.
?
$
4 reset
R
PA3
V
/ end exit
W
!
X
1
Caps
Z
Ctrl
8 pg left
L
PA2
7 pg up *
(
9
F24
Q e-eof
Y
;
home &
F
F23
P clear
F18
K PA1
U
:
E
F22
O hm
}
J stat
T e-Inp
F16
I
N
S
{
D
F21
NL
M
C l
=
H AT
'
F15
C
F20
-
G "
+
B
F19
`
F14 f
Alt pg right %
5
^
6 enter pg dn
@
#
2
3 ins del
)
> space
0
Esc num lock
.
enter
3270
~
F13
_
A -
G sysrq
'
S e-Inp
C l
Y
5250
2-14
=
H N \
{
F21
[ stat
<
T
|
F22 clear
E ]
U attn
;
V
?
help
W
F24
7
$
4
Alt
8 exit
X
!
f
(
9 pg right %
5 end
^
6 pg dn
1
Caps
Ctrl pg up * pg left reset
R / home &
L R
Q .
F18
F
F23
>
P ,
:
K R err rst
Z
}
J
O hm
F16
D
I NL
M
F15
C
F20
AT
"
+
B
F19
`
F14 space
@
2
# ins del
)
>
0
3
Esc fld exit
.
num lock enter
2050U.019
Page 54
39 nugget A Operating the JANUS 2050
2
Accessing TE Commands on the Keypad As on all terminal keyboards, the keys on the JANUS 2050 TE keypad have their main function marked directly on the key itself. To access that character or function, just press the key. Your JANUS 2050 TE provides access to additional keys and commands. These keys are described below. Note: When entering a key combination on the JANUS 2050, you do not need to press and hold the c , a , u , or f keys. Once you press a key, the JANUS 2050 stores the keystroke in memory and uses it with the next keystroke as a key combination.
Shift Key The u key accesses uppercase letters. For example, for the letter “A” you press u A . This key also accesses the mathematical symbols printed on the number keys.
Ctrl and Alt Keys The c and a keys let you access characters or commands on the keypad that are printed above the letter keys and function keys. The c key has the color green above it and activates the commands printed in green. Similarly, the a key activates commands printed in blue. To use the c and a keys, simply press and release the key, and then press the corresponding key that has the desired command or character printed above it. For example, to create an equal sign (=), press c and then press I . Note: When you exit TE and return to the DOS prompt, the c key will no longer be accessing the characters printed above the letter keys. Use the f key instead.
Compound Function Key On a regular JANUS 2050 keypad, the f key can be pressed multiple times to access even more sets of commands. You can press the f key up to three times to access different sets of commands. These commands are not available when you are using terminal emulation software.
2-15
Page 55
JANUS 2050 Vehicle Mount Computer User’s Manual (4MB)39 nugget A
Booting the JANUS 2050 You can perform a cold boot or warm boot on the JANUS 2050.
Performing a Cold Boot A cold boot invokes the BIOS boot sequence, the bootstrap verifies that the 256K system flash is not corrupt, clears all memory, and does a complete power-on-self-test (POST) to ensure that the hardware and peripherals are operational. It also initializes the system hardware for subsequent use by the system software, loads the configuration file JANUS.INI if present (otherwise, it loads the default configuration), runs AUTOEXEC.BAT and CONFIG.SYS, and brings up DOS. Drive E is initialized on a cold boot and all files on the drive are lost. To performs a cold boot, select Reboot from the Boot Loader menu. The Boot Loader menu is described later in this chapter.
Performing a Warm Boot A warm boot goes through POST, and runs CONFIG.SYS and AUTOEXEC.BAT, and then goes to the DOS prompt. Memory remains intact on a warm boot. You initiate a warm boot when you press c a f . .
CAUTION
Caution Do not press any keys while the JANUS 2050 is performing a warm boot or you may lose data. Conseil N’appuyez pas sur des touches pendant que le lecteur se réamorce, sinon vous pouvez perdre des données.
2-16
Page 56
39 nugget A Operating the JANUS 2050
2
Understanding the Status LEDs The four LEDs located to the left of the screen display the status of the following JANUS 2050 functions.
I/O
Conn
Data
Ctrl
Alt
Shift
Caps
Status LEDs f
2050U.004
Status LEDs
Color
Description
Conn
Data
Yellow
Indicates communication with the network controller is established.
Conn
Data
Red/Orange
Data is buffered in the JANUS 2050 RF interface.
Note: Do not turn off the JANUS 2050 when the Conn/Data light is on. When you power up, the JANUS 2050 attempts to send any data in the radio buffer. Depending on the time between power down and power up, this data could be meaningless and/or disrupt the host application. The operator who turns on the unit could also be confused by a display screen containing instructions or data unrelated to his or her work. Conn
Data
Green
A connection is established with the network controller and data transfer is taking place.
Ctrl
Alt
Yellow
Ctrl c function is enabled.
Ctrl
Alt
Red/Orange
Alt a function is enabled.
Ctrl
Alt
Green
Both Ctrl c and Alt a functions are enabled.
2-17
Page 57
JANUS 2050 Vehicle Mount Computer User’s Manual (4MB)39 nugget A Status Lights (continued) Status LEDs
Color
Description
Shift
Caps
Yellow
Shift function is enabled.
Shift
Caps
Red/Orange
Caps u function is enabled.
Shift
Caps
Green
Both Shift and Caps u functions are enabled.
f
Yellow
Compound function f 1 is enabled.
f
Red/Orange
Compound function f 2 is enabled.
f
Green
Compound function f 3 is enabled.
Caution Always wait for the Conn/Data light to go off before changing protocols, turning off the unit, or inserting a cable. The data light will go off when all data is transferred from the JANUS 2050. Conseil Attendez toujours que le voyant des données s'éteigne avant de changer de protocole, d'éteindre l'unité ou d'insérer un câble. Le voyant des données s'éteindra lorsque toutes les données seront transférées de la JANUS 2050.
2-18
Page 58
39 nugget A Operating the JANUS 2050
2
Display Modes The JANUS 2050 display is CGA compatible with enhanced features for DOS code page support. The default configuration for the JANUS 2050 display is 25 rows by 80 characters. You can use the JANUS 2050 in Text or Graphics mode. When the JANUS 2050 is in Text mode, you can set the display size to 25 x 80, 13 x 80, 25 x 40, or 13 x 40. You also have the option of doubling the character height or width without reducing the display area. You can change the display setup in the JANUS 2050’s configuration. The JANUS 2050 also supports two character attributes: blinking and reverse video. To use Graphics mode, your application needs to set Graphics mode when you start the application on the JANUS 2050. As you exit the application, set Text mode again before returning to the DOS prompt. When you use the JANUS 2050 in graphics mode, it has a 640 x 200 pixel display. For help on programming the JANUS 2050 or setting Graphics mode, see the JANUS PSK reference manual set.
2-19
Page 59
JANUS 2050 Vehicle Mount Computer User’s Manual (4MB)39 nugget A
Understanding Audio Signals and Beep Sequences The JANUS 2050 has a beeper to indicate status. The following table indicates the purpose of each beep sequence or audio signal. You can change the beep volume in the JANUS 2050’s configuration. Signal/Beep Sequence
Meaning
L
Valid command or data accumulated.
H
Valid data entered, label decoded, last row of a two dimensional symbology decoded, or the power-on-self-test (POST) passed on a cold boot.
LH
Valid PC card inserted.
HL
Valid PC card removed.
LLL
Invalid command or data, or an IRL syntax error was found while compiling.
LHL
IRL runtime error (a nonfatal error).
HLH
Input/output (I/O) error.
HHH
Configuration error or a fatal IRL error.
LLHH
Updating JANUS 2050 configuration.
C
Key pressed.
C
One row of a two-dimensional symbology decoded (Code 16K and Code 49).
Chirp (continual)
Battery is low. Chirp sounds every 15 seconds.
Shadow or double beep/click
Battery is low. The second beep or click is a lower tone that shadows the first.
C=click, L=low beep, H=high beep
2-20
Page 60
39 nugget A Operating the JANUS 2050
2
Estimating Power Usage You can use the following information as a guideline for estimating typical power usage. Internal combustion vehicles A typical battery has a capacity of 60 Amphours (Ah). The JANUS 2050 typically draws 1.8A at 12V. To find the length of time the JANUS 2050 can operate before recharging the vehicle battery, divide the capacity of your battery by the amount of power drawn hourly. Your calculation should be similar to the following: 60Ah/1.8A = 33.3 hours or 1.4 days If you start with a fully charged battery, the JANUS 2050 can operate for 33.3 hours or approximately 1.4 days before draining the vehicle battery. Electric vehicles Electric vehicles have higher capacity batteries than internal combustion vehicles. The standard electric vehicle battery is so large that leaving the JANUS 2050 powered on for long periods of time has no noticeable effect on the vehicle battery.
Recharging the Backup Battery The JANUS 2050 is normally powered by the batteries of the vehicle to which it is attached. The internal NiCad battery supplies power to the real-time clock and processor RAM when you remove or discharge the vehicle. The NiCad battery must be replaced by an Intermec service technician. If you turn on the JANUS 2050 when the battery charge is low, the JANUS 2050 beeps and displays a “Backup Battery Low” message. You should recharge the battery immediately. To recharge the backup battery 1. Press the q button to suspend the JANUS 2050 while input power is connected and the rear power switch is in the ON position. 2. The backup battery will charge enough to operate the unit normally on an external power supply within 20 minutes. To be fully functional, the backup battery should charge for approximately 10 hours. Note: If you continue to operate the JANUS 2050 without charging the backup battery, the JANUS 2050 beeps every 15 seconds for 1 minute and then turns off.
2-21