Page 401
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB)
Reader Services A collection of programs on the device that decode bar codes, process data input and output, configure the device, and handle power management. records per block The maximum number of data records transmitted per block of data. A block of data is transmitted during a single transmission event. regular label A bar code label that takes the form of <start code data stop code>. A regular bar code label is executed as soon as you scan it. Contrast with multiple-read label. remark out When you add a REM statement (short for REMark) at the beginning of a command line in a batch file, DOS treats the line as a remark instead of as a command. Any statement beginning with the characters REM will be ignored by the command processor. Typically, users will remark out device drivers in AUTOEXEC.BAT and CONFIG.SYS startup files. REQ Request for Acknowledgment character. Sent by the device to the host to request a retransmission of an acknowledgment to a message. RES Reset character. Sent by the device to end communications with the host. The RES character enables or disables the reset event, or resets the data transmission event to the solicitation event. resume When you press q to turn the device back on, the device resumes exactly where it was when you turned it off. If a program was running when you turned off the device, the program continues running from the same point when you turn the device back on. RF data collection system Radio frequency data collection system in which the individual components communicate with each other by radio signals. RFPH The RF protocol handler, which enables a JANUS device to communicate as an end device in an RF network. RFPH lets the device transmit and receive data as specified by the RF communications protocol.
G-20
Page 402
Glossary
G
ROM Read only memory. Usually a small memory that contains often-used instructions, such as microprograms or system software. ROM is programmed during memory fabrication and cannot be reprogrammed. ROM drive A read-only memory drive. Drives C and D are ROM drives implemented in flash memory on the device. scanner timeout Maximum time the laser is on. The laser will automatically turn off if timeout occurs before the trigger is released. SEL Select character. The character that requests permission for the controller to send data to the polled device. serial communications With serial communications, data is transmitted one bit at a time over a single line from one computer to another. Often serial communications link host computers to terminals and PCs to printers. serial communications parameters Parameters that control serial communications from one computer to another, such as baud rate and parity. server The computer that contains the drives, directories, files, and programs you want to access. See also client. SOM Start of Message character. The first character in messages sent to or received from the host. SOP Start of Program Block character. Sent by the host at the beginning of a block of IRL program statements. spotting beam An aiming feature of a laser scanner. A small beam of light briefly shines on the object being scanned, allowing the operator to position the scanner correctly for a good read.
G-21
Page 403
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB)
SRAM drive Static RAM. See RAM drive. SRAM PC card A type of memory PC card that provides additional disk storage space, not more executable conventional memory, on the device. An SRAM card has a lithium battery to back up data for the life of the battery. stop bits A bit that signals the end of a character. One of the serial communications parameters. Suspend mode The mode the JANUS device enters when you press q to turn off the device. In Suspend mode, the device saves all memory and turns off the power to most hardware, including the CPU. symbology See bar code symbology. timeout A defined time allowed for an event after which an alternative action is taken. timeout delay The time the device waits between received characters before an I/O (input/output) error occurs. TSR program Terminate and stay resident program. A DOS program that remains loaded in conventional memory after you have terminated it. You must explicitly unload the TSR if you want to free the conventional memory it is using. UART buffer Universal Asynchronous Receiver/Transmitter buffer. The UART buffer contains bytes of data being sent or received by the device. The FIFO control register controls how the UART buffer operates.
G-22
Page 404
Glossary
G
UPC/EAN Code A fixed length, numeric, continuous bar code symbology that uses four element widths. A device that is configured to decode EAN bar codes can decode UPC, but the reverse is not true. UPC code is a subset of EAN code. It is a numeric, 12-digit bar code symbology used extensively in retail, particularly the grocery industry. The character set is 0 to 9. Its maximum character density is 13.8 numeric characters per inch. upline A device that is at the computer end of a connection between a computer and a device is referred to as being upline. When devices are connected to a computer, they are connected in a “line.” Upline is a direction relative to the device, in contrast to downline. upper memory area The area between the 640K and 1024K. The upper memory area is physically composed of a 256K flash ROM chip (system flash) and the video memory chip. Like a PC, this area contains the BIOS and video buffers. The upper memory area also contains PC card memory and ROM DOS. The 384K upper memory area maps just above 640K conventional memory. User-Defined protocol A custom communications protocol that can be modified to meet specific host requirements. For example, you can configure User-Defined to act like a Pointto-Point protocol, except that it requires an LRC and an acknowledgment from the receiver. You can also define the communications characters such as SOM, POL, or SEL, or disable these characters by setting them to null. vertical reading angle The vertical angle of a laser scanner to a bar code label. The optimum vertical reading angle is near 20 degrees. Virtual Wedge A Reader Services feature that lets the device decode bar codes, making the device functionally equivalent to a wedge device connected to a PC. volatile Refers to memory that is not saved when power is lost or turned off.
G-23
Page 405
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB)
warm boot One of two ways to boot the device; compare to cold boot. A warm boot performs the power-on self test (POST) to ensure that the hardware and peripherals are operational, runs CONFIG.SYS and AUTOEXEC.BAT, and displays the DOS prompt. The contents of both conventional memory and the physical RAM drive (drive E) remain intact. You may warm boot the device to execute startup files, such as AUTOEXEC.BAT, that have changed. You may also warm boot to start Interlnk. XON/XOFF A type of software flow control for communications between digital devices. It stops the host from sending data when the device buffer fills up (XOFF) and starts it again when the buffer empties (XON).
G-24
Page 406
I Index
Page 407
Page 408
Index
Numbers 9154 Multi-Drop Line Controller for BFT, 6-26 9180 Network Controller for BFT, 6-26
A Adding files to drive C, 3-16 Address, Multi-Drop, 10-5, A-6 advanced power management, using, C-9 AFF, 10-6 Alt key, 2-6 APM_4M.EXE defined, 3-7 loading, 3-7, 5-16 troubleshooting, 8-11 Application storage, 2-24 applications downloading with BFT, 6-22–6-32 ASCII bar code chart, A-19 Code 39 full, 10-20 mixed-full, 10-20 non-full, 10-20 control characters, 9-7 configuring preamble/postamble, 4-9, A-4 configuring protocol characters, 4-9, A-3 Data Link Exception (DLE), 9-7 entering characters (0 to 255), 2-8 equivalents, A-16 ASCII GS character, 10-27 ATA card defined, 5-4 initializing and formatting, 5-10 ATADRV.EXE, 5-10 ATAINIT.EXE, 5-10 Audio signals, 2-20 Audio signals, when inserting a PC card, 2-20 AUTOEXEC.BAT defined, 3-6 editing on drive C, 3-10, 3-13 I/O cards, configuring, 5-15 loading a configuration file with IC.EXE, 4-11 Auto-Loader batch files reference information, C-10–C-15 drive C using Auto-Loader to change, 3-11, C-10 Auto-Loader utility, 3-4, 3-14 creating and loading a new drive C, 3-16 creating image files, 3-18 installing, 3-14 loading image files, 3-20 overview, 3-13
I reader locks up, 8-13
B Backspace, destructive, 9-5 Backup battery, 2-21 charging, 2-21 time for full charge, 2-21 Bad BIOS Checksum error message, 8-3 Bad command or filename, 8-10 Bad Saved State, 8-4 BAK, IRL, 10-56 Bar code ASCII chart, A-19 configuration overview, 4-3 configuring with, 4-6 creating configuration labels, 4-14 decode security, 10-43 Enable override, 8-7 Exit IRL program, 8-9 moving the cursor with bar codes, A-22 symbologies Codabar, 10-14 Code 11, 10-16 Code 128, 10-27 Code 16K, 10-17 Code 39, 10-20 Code 49, 10-24 Code 93, 10-26 function code 1, 10-24 function code 2, 10-24 Interleaved Two of Five, 10-54 MSI, 10-68 Plessey, 10-72 Two of Five, 10-18 UPC/EAN, 10-94 Bar code symbologies default settings, A-23 bar code wedge configuring, 3-30 default configuration, 3-31 Bar codes problems scanning, 8-22 batch file for Auto-Loader, C-10–C-15 to install Auto-Loader, 3-4 battery pack power status, displaying, C-9 baud rate, 10-7 38400 bps, 8-26 57600 bps, 8-26 for BFT, 6-26 for Loader, 8-26 Beep duration, 10-9 frequency, 10-11
I-3
Page 409
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB)
status indication, 2-20 volume, 10-13 BFT application, starting automatically, 6-29 baud rate restrictions, 6-26 Cancel the Prepare for Reboot command, 9-8 Cancel the Reboot command, 9-9 client, using the device as, 6-27 defining a typical session, 6-25 downloading applications, 6-22–6-32 drive C, using to change, 3-11 example, illustrated, 6-23, 6-24 FTA commands, using, 6-29 FTA initialization file, editing, 6-32 Prepare for Reboot command, using, 9-8 preparing the device and host computer, 6-26 Reboot command, using, 9-9 server, using the device as, 6-28 Binary File Transfer defined, 3-4 Boot Loader menu, 11-4 dump, 11-5 load, 11-5 off (exiting), 11-5 password, 11-5 setting, 11-6 reboot, 11-4 resume, 11-5 storage mode, 11-5 entering, 11-6 exiting, 11-7 system flash corrupt, 8-3 troubleshooting, 8-3 Boot utilities, 3-3 Booting the JANUS 2050, 2-16, 11-4 booting the reader, 4-11 Buffered display, 10-44
C Cancel the Prepare for Reboot command, 9-8 Cancel the Reboot command, 9-9 Card. See PC card CARDINFO.EXE, 5-17 Cards overview, PC cards, 5-9 Cfg menu in Communications Manager, 6-20 changing drive C learning how to, Error! Not a valid bookmark in entry on page 3-10, C-10 changing drive C or D, using MakeDisk and PutDisk, 321 CHECKHOST, FTA command, 6-30 Clear command, 9-6 Clicker, keypad, 10-65 Client, making Interlnk the, 6-13
I-4 client/server BFT, illustrated, 6-27 Interlnk, using, C-3–C-6, C-7 CLOSE, FTA command, 6-30 Codabar, 10-14 Code 11, 10-16 Code 128, 10-27 Code 16K, 10-17 Code 39, 10-20 Code 49, 10-24 Code 93, 10-26 Code pages, switching in DOS, 2-9 Cold boot, 2-16, 11-4 Com menu in configuration application, 4-7 COM port connector, B-4 COM port pin assignments, B-5 Command concatenated, 9-3 configuration command syntax listing, A-27 override command, 9-7 Command processing, 10-28 Command, comfiguration multiple-read labels, 10-28 Command, configuration, 4-14, 9-6 address, Multi-Drop, 10-5 AFF, 10-6 BAK, IRL, 10-56 baud rate, 10-7 beep duration, 10-9 frequency, 10-11 volume, 10-13 Codabar, 10-14 Code 11, 10-16 Code 128, 10-27 Code 16K, 10-17 Code 39, 10-20 Code 49, 10-24 Code 93, 10-26 COM1 Port UART - Restore, 10-35 COM2 Port UART - Restore, 10-34 command processing, 10-28 communication port UART, 6-11 communications port, 10-33 communications protocol, 10-37 activate, 10-40 User-Defined Multi-Drop, 10-41 data bits, 10-42 decode security, 10-43 display mode, IRL, 10-44 setup, 10-45
Page 410
Index
END, IRL, 10-57 EOF, 10-47 EOM, 10-48 EOP, IRL, 10-58 EOR, 10-50 flow control, 10-51 function code 1, 10-24 function code 2, 10-24 intercharacter delay, 10-52 Interleaved Two of Five, 10-54 key code lookup table, 10-63, A-7 keypad clicker, 10-65 Ctrl key functions, 10-66 Keypad Caps Lock, 10-64 LRC, 10-67 MSI, 10-68 NEG, 10-70 overview, 10-3 PAK, IRL, 10-59 parity, 10-71 Plessey, 10-72 POL, 10-73 postamble, 10-74 preamble, 10-75 PSS, IRL, 10-60 records per block, 10-76 REQ, 10-78 RES, 10-79 RUN, IRL, 10-61 scan ahead, 10-80 scanner devices, 10-81 mode, 10-82 redundancy, 10-83 timeout, 10-84 trigger, 10-85 SEL, 10-86 SOM, 10-87 SOP, IRL, 10-62 stop bits, 10-88 syntax cross-reference, A-27 timeout delay, 10-89 transmit abort timeout, 10-91 turnaround delay, 10-93 Two of Five, 10-18 UPC/EAN, 10-94 variable data, working with, 10-4 Command, JANUS 2050 backspace, destructive, 9-5 change configuration, 9-6 clear, 9-6 command override, 9-7 enter, 9-8 Enter/Exit Accumulate, 9-4
I
Prepare for Reboot, 9-8 Command, reader, 9-3 disabling commands, 10-28 COMMAND.COM, 8-12 Commands, JANUS 2050 Reboot, 9-9 Communication parameters address, Multi-Drop, 10-5 AFF, 10-6 baud rate, 10-7 data bits, 10-42 EOF, 10-47 EOM, 10-48 EOR, 10-50 flow control, 10-51 intercharacter delay, 10-52 IRL BAK, 10-56 IRL END, 10-57 IRL EOP, 10-58 IRL PAK, 10-59 IRL PSS, 10-60 IRL RUN, 10-61 IRL SOP, 10-62 LRC, 10-67 NEG, 10-70 parity, 10-71 POL, 10-73 records per block, 10-76 REQ, 10-78 RES, 10-79 SEL, 10-86 SOM, 10-87 stop bits, 10-88 timeout delay, 10-89 transmit abort timeout, 10-91 turnaround delay, 10-93 Communication port UART, 6-11 Communication protocol disabling protocol characters, 4-9 User-defined, 6-4 Communications configuration overview, 4-4 configuring for, 6-7 configuring protocol characters, 4-9 CrossBar, Multi-Drop protocol, 6-5, 6-7 Exiting Interlnk/Intersvr, 6-18 Interlnk, 6-4, 6-13 executing on the host computer, 6-16 executing on the JANUS 2050, 6-17 Interlnk, using to transfer files, C-3–C-6 Interlnk/Intersvr status, 6-18 Intersvr, defined, C-7 IRL Desktop, 6-4, 6-13
I-5