Page 271
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Intercharacter Delay Purpose:
Defines the amount of time the JANUS 2050 waits before sending each character to the host. It modifies outgoing data only by slowing the speed of transmission. A character delay can be useful when communicating with a controller through modems using full-duplex operation. Note: You must select the communications port and protocol before setting the parameters that define the protocol. Refer to the configuration command “Communications Protocol, Configure” earlier in this chapter for more information on defining protocols.
Default:
0 sec
Syntax:
IDdata Acceptable values for data are: 0 1 2 3 4 5 6 7
Scan:
0 ms 1 ms 2 ms 5 ms 10 ms 20 ms 50 ms 100 ms
One of the following labels: 0 ms Intercharacter Delay
1 ms Intercharacter Delay
*$+ID0*
*$+ID1*
*$+ID0*
*$+ID1*
2 ms Intercharacter Delay
5 ms Intercharacter Delay
*$+ID2* *$+ID2*
10-52
*$+ID3*
*$+ID3*
Page 272
39 nugget A Configuration Commands
10
Intercharacter Delay (continued 10 ms Intercharacter Delay
20 ms Intercharacter Delay
*$+ID4*
*$+ID5*
50 ms Intercharacter Delay
100 ms Intercharacter Delay
*$+ID4*
*$+ID6* *$+ID6*
*$+ID5*
*$+ID7*
*$+ID7*
10-53
Page 273
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Interleaved 2 of 5 Purpose:
Enables/disables decoding of Interleaved 2 of 5 symbology. Interleaved 2 of 5 is a high-density, self-checking, continuous numeric symbology. It is mainly used in inventory distribution. Enabling Interleaved 2 of 5 automatically disables 2 of 5.
Default:
Variable length with a check digit
Syntax:
CAdata Acceptable values for data are: 0 2-32 97 98 99
CAUTION
Disabled Fixed length (even number only) Variable length without a check digit Case code (6 or 14) with a check digit Variable length with a check digit
Caution Using the variable length without a check digit configuration option can cause substitution errors. Conseil Des erreurs de substitution peuvent survenir si vous utilisez la longuer variable sans option de vérification de configuration de chiffres.
Scan:
One of the following labels: Disable Interleaved 2 of 5
Variable Length With a Check Digit
*$+CA0*
*$+CA99*
Variable Length Without a Check Digit
Interleaved 2 of 5, Case Code
*$+CA97*
*$+CA98*
*$+CA0*
*$+CA97*
10-54
*$+CA99*
*$+CA98*
Page 274
39 nugget A Configuration Commands
10
Interleaved 2 of 5 (continued) Or:
To set Interleaved 2 of 5 to fixed length: 1. Scan the following bar code: Enter Accumulate / Fixed Length
*+/$+CA* *+/$+CA*
2. Scan a numeric value for data from the following bar codes (even numbers 2 through 32 only):
*0* *0*
*2*
*1* *1*
*3*
*2*
*3*
*4*
*6*
*4*
*6*
*8* *8*
3. Scan the following bar code: Exit Accumulate
*-/* *-/*
10-55
Page 275
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
IRL BAK (Bad Program Acknowledge) Purpose:
A BAK is sent from the JANUS 2050 to indicate that an IRL program cannot be successfully downloaded. Note: You must select the communications port and protocol before setting the parameters to define that protocol. Refer to the configuration command “Communications Protocol, Configure” earlier in this chapter for more information on defining protocols.
Default:
BEL
Syntax:
ZBdata data can be any ASCII character.
Scan:
To disable BAK, scan the following bar code: Disable BAK
*$+ZB* *$+ZB*
Or:
To set BAK to an ASCII character: 1. Scan the following bar code: Enter Accumulate / BAK
*+/$+ZB* *+/$+ZB*
2. Scan a bar code for data from the full ASCII chart in Appendix A. 3. Scan the following bar code: Exit Accumulate
*-/* *-/*
10-56
Page 276
39 nugget A Configuration Commands
10
IRL END Program Block Purpose:
Indicates the last block of an IRL program when downloading a program to the JANUS 2050. Note: You must select the communications port and protocol before setting the parameters to define that protocol. Refer to the configuration command “Communications Protocol, Configure” earlier in this chapter for more information on defining protocols.
Default:
SO (shift out)
Syntax:
XDdata data can be any ASCII characters.
Scan:
To disable END, scan the following bar code: Disable END
*$+XD* *$+XD*
Or:
To set END to an ASCII character: 1. Scan the following bar code: Enter Accumulate / End of IRL Program Block
*+/$+XD* *+/$+XD*
2. Scan a bar code for data from the full ASCII chart in Appendix A. 3. Scan the following bar code: Exit Accumulate
*-/* *-/*
10-57
Page 277
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
IRL EOP (End of Program) Purpose:
An EOP indicates the end of an IRL program block when downloading a program to the JANUS 2050. Note: You must select the communications port and protocol before setting the parameters to define that protocol. Refer to the configuration command “Communications Protocol, Configure” earlier in this chapter for more information on defining protocols.
Default:
SYN (synchronous idle)
Syntax:
XBdata data can be any ASCII character.
Scan:
To disable EOP, scan the following bar code: Disable EOP
*$+XB* *$+XB*
Or:
To set EOP to an ASCII character: 1. Scan the following bar code: Enter Accumulate / EOP
*+/$+XB* *+/$+XB*
2. Scan a bar code for data from the full ASCII chart in Appendix A. 3. Scan the following bar code: Exit Accumulate
*-/* *-/*
10-58
Page 278
39 nugget A Configuration Commands
10
IRL PAK (Program Acknowledge) Purpose:
This character is sent by the JANUS 2050 to the host computer to acknowledge a received IRL program. Note: You must select the communications port and protocol before setting the parameters that define the protocol. Refer to the configuration command “Communications Protocol, Configure” earlier in this chapter for more information on defining protocols.
Default:
RS (record separator)
Syntax:
ZAdata data can be any ASCII character.
Scan:
To disable PAK, scan the following bar code: Disable PAK
*$+ZA* *$+ZA*
Or:
To set the PAK to an ASCII character: 1. Scan the following bar code: Enter Accumulate / PAK
*+/$+ZA* *+/$+ZA*
2. Scan a bar code for data from the full ASCII chart in Appendix A. 3. Scan the following bar code: Exit Accumulate
*-/* *-/*
10-59
Page 279
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
IRL PSS (Program Statement Separator) Purpose:
Separates individual IRL program statements from each other. Note: You must select the communications port and protocol before setting the parameters that define the protocol. Refer to the configuration command “Communications Protocol, Configure” earlier in this chapter for more information on defining protocols. Do not define PSS as the same character used for EOM.
Default:
CR (carriage return)
Syntax:
XEdata data can be any ASCII character.
Scan:
To disable PSS, scan the following bar code: Disable PSS
*$+XE* *$+XE*
Or:
To set the PSS to an ASCII character: 1. Scan the following bar code: Enter Accumulate / PSS
*+/$+XE* *+/$+XE*
2. Scan a bar code for data from the full ASCII chart in Appendix A. 3. Scan the following bar code: Exit Accumulate
*-/* *-/*
10-60
Page 280
39 nugget A Configuration Commands
10
IRL RUN Purpose:
Designates the end of an IRL program download and causes the JANUS 2050 to execute the program. RUN takes the place of the last EOP character in the downloaded program. Note: You must select the communications port and protocol before setting the parameters that define the protocol. Refer to the configuration command “Communications Protocol, Configure” earlier in this chapter for more information on defining protocols.
Default:
DC2
Syntax:
XCdata data can be any ASCII character.
Scan:
To disable RUN, scan the following bar code: Disable RUN
*$+XC* *$+XC*
Or:
To set RUN to an ASCII character: 1. Scan the following bar code: Enter Accumulate / RUN
*+/$+XC* *+/$+XC*
2. Scan a bar code for data from the full ASCII chart in Appendix A. 3. Scan the following bar code: Exit Accumulate
*-/* *-/*
10-61