The text of a manual · part 19 of 42
JANUS 2050 Vehicle-Mount Computer (4MB) User's Manual, pages 181 to 190
Pages 181 to 190 of 419
The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec J2050
Page 181
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
IRL Program, Download Purpose:
Downloads an IRL program from the host computer. The <SOP> character can be set in the JANUS 2050’s configuration. The default is <SI>. The default IRL program filename is {IRL-1}.IRL. If there is an {IRL-1}.IRL program already on the JANUS 2050, it is overwritten.
From host:
<SOP>
Keypad:
Not supported
IRL command:
Not supported
Scan:
Not supported
IRL Program, Exit Purpose:
Exits an executing IRL program.
From host:
/$
Keypad:
Not supported (Refer to application break sequence information earlier in this chapter.)
IRL command:
Not supported
Scan:
Exit Program
*/$* */$*
7-18
Page 182
39 nugget A Working With IRL
7
IRL Program, Resume Purpose:
Resumes execution of a suspended IRL program.
From host:
$.
Keypad:
Use the Resume option on the File menu.
IRL command:
Not supported
Scan:
IRL Resume
*$.* *$.*
IRL Program, Run Purpose:
Executes the default IRL program named {IRL-1}.IRL.
From host:
//
Keypad:
Use the Run option on the File menu.
IRL command:
Not supported
Scan:
Run IRL Program
*//* *//*
7-19
Page 183
Page 184
code nugget 39 helcond
8 Troubleshooting
Page 185
Page 186
39 nugget ATroubleshooting code nugget 39 helcond
8
This chapter lists problems that may occur when you operate the JANUS 2050 and provides possible solutions to those problems. It also provides different options for resetting the JANUS 2050, and describes how to save data and update flash memory.
Troubleshooting the JANUS 2050 If you have problems operating the JANUS 2050, review the following tables listing problems and their possible solutions. Problems are grouped into common areas for easier reference. For example, problems you might see while running an IRL program are grouped in one table.
Powering Up or Booting the JANUS 2050 This table lists problems that may occur when turning the JANUS 2050 on or off, or when booting the JANUS 2050. Problem
Solution
When you turn on or cold boot the reader, the Boot Loader menu appears. The menu may not list all the Boot Loader commands, and the screen may include a status message. For example, the partial Boot Loader menu may look like this:
The bootstrap checks the system flash when doing a resume or cold boot. If the system flash is corrupt or there are bad checksum error messages, it brings up the Boot Loader menu. Read the status messages at the bottom of the menu.
Boot
If you see “Bad BIOS Checksum” or a message that indicates the system flash is corrupt, you could save the contents of conventional memory using the Dump menu selection, but you must reload the system flash. If the system flash memory is corrupt, you can dump memory and reload the system flash. For more information about reloading flash memory, see “Saving Data and Loading Flash Memory” later in this chapter.
Loader
Dump Load Storage Off
Bad BIOS Checksum Please Load BIOS
20X0A.003
8-3
Page 187
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Powering Up or Booting the JANUS 2050 (continued) Problem
Solution
Other Boot Loader menu messages may look like this:
If you see “Bad Saved State,” the device may have been in Storage mode. Press to reboot. If you are prompted to exit Storage mode, press again.
Boot
@ @
@
Reboot Password Dump Load Resume Storage Off
Other self-explanatory messages may display on bottom of the Boot Loader menu.
Power-On Override Okay To Resume
20X0A.001
@
For messages in the following group, choose Reboot on the Boot Loader menu and press . •
“System Has Reset Please Reboot”
•
“Bad CMOS Checksum, Errors Please Reboot”
•
“DRAM Check Failed Please Reboot”
@
For the messages in the following group, choose Resume or Reboot on the Boot Loader menu and press .
8-4
L
You may also see the “Bad Saved State” message if you press to suspend the device while it is booting. Press to reboot the device. You may be able to save the contents of the physical RAM drive.
Loader
•
“Keypad Fault Found Okay to Resume”
•
“Power-On Override Okay to Resume”
•
“Power-Off Timeout, Errors Okay to Resume”
•
“Power-Off Forced Okay to Resume”
Page 188
39 nugget ATroubleshooting code nugget 39 helcond
8
Powering Up or Booting the JANUS 2050 (continued) Problem
Solution
During a warm boot, the JANUS 2050 cannot finish booting and displays an error message.
If you press a key (especially the Ctrl, Alt, Shift, Caps Lock, or Compound function keys) before the JANUS 2050 has finished booting, you may see the message, “FA Keyboard Error, Press F1 or F2.” Press m to exit the error screen and the JANUS 2050 will continue booting. If the JANUS 2050 appears to be locked up, press q to suspend the JANUS 2050. When you turn the JANUS 2050 back on, the Boot Loader menu displays the message, ”Bad Saved State.” Press e to reboot the JANUS 2050.
Caution Do not press any keys while the JANUS 2050 is performing a warm boot or you may lose data. Conseil N’appuyez pas sur des touches pendant que le lecteur se réamorce, sinon vous pouvez perdre des données. When the JANUS 2050 is turned on, it goes to the Boot Loader menu.
If the JANUS 2050 was in storage mode, it will display a “Bad Saved State” message. Press e to reboot the JANUS 2050. When the next screen is displayed, press e again to exit storage mode. You can also see the “Bad Saved State” message if you press the q key to suspend the JANUS 2050 while it is booting. Press e to reboot the JANUS 2050.
Caution When the JANUS 2050 performs a cold boot, all data on the RAM disk is destroyed. Conseil Lorsque le lecteur s’amorçe à froid, les données se trouvant sur le disque RAM sont détruites.
8-5
Page 189
JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A
Powering Up or Booting the JANUS 2050 (continued) Problem
Solution
The JANUS 2050 does not turn off when you press the q button.
The JANUS 2050 is locked up. Press q - 5 -j to turn off the JANUS 2050. When you turn the JANUS 2050 on, the JANUS 2050 displays the Boot Loader menu. From the menu, you can try dumping memory to a host computer or you can do a cold boot.
Caution When the JANUS 2050 performs a cold boot, all data on the RAM disk is destroyed. Conseil Lorsque le lecteur s’amorçe à froid, les données se trouvant sur le disque RAM sont détruites.
8-6
Page 190
39 nugget ATroubleshooting code nugget 39 helcond
8
Operating the JANUS 2050 The next table lists problems that may occur when operating the JANUS 2050. For example, if you have problems entering or scanning data, some possible solutions are listed in the following table. Problem
Solution
You cannot tell if the numeric keypad is enabled or disabled.
You can check if the numeric keypad is enabled or disabled by entering the shift character on a numeric key. For example, if you press u 5 and the JANUS 2050 displays:
JANUS 2050 commands are not working properly.
%
The numeric keypad is disabled.
5
The numeric keypad is enabled and the Num Lock is turned on.
nothing
The numeric keypad is enabled and the Num Lock is turned off.
The JANUS 2050 commands are disabled. Scan the Enable Override command shown below to temporarily enable all of the JANUS 2050 commands. You can also enable or disable JANUS 2050 commands in the configuration application (IC.EXE) program. Enable Override
*$+DC3* *$+DC3* Bar code labels will not scan.
Refer to “Scanning Bar Code Labels” later in this chapter.
The JANUS 2050 beeps every 10 seconds and cannot be turned off when you press the q button.
The JANUS 2050 is locked up. Press q - 5 - j simultaneously to turn off the JANUS 2050. When you turn the JANUS 2050 on, it displays the Boot Loader menu. Reboot the JANUS 2050.
The JANUS 2050 decodes a bar code label in a symbology other than the label’s actual symbology.
Try scanning the bar code label again. Make sure you scan the entire label. When multiple symbologies are enabled, the JANUS 2050 may decode bar code labels in a symbology other than the label’s actual symbology. Only enable the JANUS 2050 to decode the bar code symbologies that you are using.
8-7