Page 461

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

Configuration Commands by Syntax (continued) Syntax

Command

For Help, See Page

DSdata

Display Setup

12-48

DVdata

Viewport Movement Keys

12-100

DYdata

Viewport Movement Steps

12-101

DZdata

Viewport Movement Mode

12-100

EZdata

Automatic Shutoff

12-9

FAdata

EOF (End of File)

12-52

FBdata

EOR (End of Record)

12-55

FCdata

Records Per Block

12-80

HAdata

SEL (Select)

12-89

HBdata

POL

12-77

HCdata

Address, Multi-Drop

12-7

IAdata

Baud Rate

12-10

IBdata

Parity

12-75

ICdata

Stop Bits

12-91

IDdata

Intercharacter Delay

12-57

IEdata

Timeout Delay

12-92

IFdata

LRC (Longitudinal Redundancy Check)

12-72

IGdata

Turnaround Delay

12-96

IHdata

Transmit Abort Timeout

12-94

IIdata

Data Bits

12-43

ILdata

Flow Control

12-56

IPdata

Communications Dock Port

12-35

ISdata

Communications Port, Select COM Port

12-36

IVdata

Communications Port, UART Restore

12-37

KAdata

Keypad Caps Lock

12-68

KBdata

Keypad Ctrl Key Functions

12-70

KCdata

Keypad Clicker

12-69

KDdata

Keypad, Numeric

12-71

NM02data

RF Loopback

See RF guide

NM03data

RF Broadcast Receipt

See RF guide

A-12

Page 462

NF

BC Reader Specifications

A

Configuration Commands by Syntax (continued) Syntax

Command

For Help, See Page

PAdata

Communications Protocol, Activate

12-41

PCdata

RES (Reset)

12-83

PDdata

REQ (Request for Acknowledge)

12-82

PEdata

SOM (Start of Message)

12-90

PFdata

EOM (End of Message)

12-53

PGdata

AFF (Affirmative Acknowledge)

12-8

PHdata

NEG (Negative Acknowledge)

12-74

PIdata

Transmit EOM (End of Message) Only

12-53

PJdata

Receive EOM (End of Message) Only

12-53

PMdata

Communications Protocol, User-Defined Multi-Drop

12-42

PSdata

Communications Protocol, Configure

12-38

Rchannel data

RF Channel Allow

See RF guide

RFdata

RF Protocol

See RF guide

RHdata

RF Device Address

See RF guide

RLdata

RF Retry Limit

See RF guide

RMdata

RF Acknowledgment Delay

See RF guide

RTdata

RFNC (RF Network Controller) Address

See RF guide

RUdata

RF Repeat Count

See RF guide

RVdata

RF Channel Select

See RF guide

RWdata

RF Network ID

See RF guide

RXdata

RF Duty Cycle Period

See RF guide

RYdata

RF Duty Cycle Percent

See RF guide

SAdata

Scanner Timeout

12-87

SBdata

Scanner Mode

12-85

SCdata

Scanner Trigger

12-88

SDdata

Scan Ahead

12-84

SRdata

Scanner Redundancy

12-86

WMdata

Key Code Look-Up Table

12-67

XAdata

IRL SOP (Start of Program)

12-66

XBdata

IRL EOP (End of Program)

12-62

A-13

Page 463

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

Configuration Commands by Syntax (continued) Syntax

Command

For Help, See Page

XCdata

IRL Run

12-65

XDdata

IRL End Program Block

12-61

XEdata

IRL PSS (Program Statement Separator)

12-64

ZAdata

IRL PAK (Program Acknowledge)

12-63

ZBdata

IRL BAK (Bad Program Acknowledge)

12-60

A-14

Page 464

NF

BC Reader Specifications

A

Types of Memory Used in the Reader The JANUS reader uses the types of memory described in this section. Memory in the reader is similar to that of a PC in some ways, and very different in other ways. One major difference is that the reader uses memory to simulate disk drives. This memory map shows how the reader uses memory.

Memory Map Address

Contents

Description

FFFFFF E00000

No Physical Memory

End of 386SX Address Space

APPLICATION DISK Drive D

2MB Flash

C00000

Unused Address Space No Physical Memory

(3.5MB)

880000

USER FLASH Drive C

512K Flash

800000

No Physical Memory

(4MB) HIMEM is included in this 3MB

110000

3MB DRAM Extended Memory Contains 256K Drive E: HIMEM, 64K MS-DOS 6.2 Loaded

1MB Real Mode Boundary

100000 FFFFF FFFF0

RESET VECTOR (10H Bytes)

Bootstrap Vector 10H ASIC BANKED

BIOS & PM (56K)

BIOS Flash, Shadowed

F2000 F0000

INT13/19 (4K, 8K allowed) BIOS Extensions (64K)

BIOS Extensions, Shadowed

E0000

Scanner/Decodes (64K)

Upper memory block

D0000

PC Card Window (64K)

Can be used for optional upper memory

C0000

400000

A-15

Page 465

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

Memory Map (continued) Address

Contents

Description

VIDEO Memory (32K)

Video SRAM, DRAM

B8000

Masked Out Reader Services and Configuration Manager Code and Data (95k)

A0000 9A800

32K BANKED Bootstrap ROM

BIOS Extension Data (22K)

End of 640K DRAM

Conventional Memory (527K)

User Memory

Note: This area also contains any additional needed drivers.

16AA0 MS-DOS and PC card Data and Drivers (89K)

Includes MS-DOS data and IO.SYS, POWER, HIMEM, SRAMDISK, CS, CSALLOC, MTSRAM, MTDDRV, CARD_SR, and COMMAND.COM stub.

BIOS GDT MS-DOS Data Area BIOS Data Area Vector Table

Reserved for BIOS/MS-DOS (1.8K)

700

0

Conventional Memory (0 Through 640K) Your 4MB JANUS device has 4MB of battery-backed dynamic RAM. The first 640K is conventional memory and is virtually the same as that of a PC. You can use this memory to run applications. The MS-DOS 6.2 operating system loads at 0 (zero) and works up, followed by the statements and drivers in the CONFIG.SYS file, then COMMAND.COM, TSR (terminate and stay resident) programs, and commands in the AUTOEXEC.BAT file, just like a PC.

Upper Memory Area The area between the 640K and 1024K is known as the upper memory area. The upper memory area is physically composed of a 256K flash ROM chip (system flash) and the video memory chip under the DRAM memory. Like a PC, this area contains the BIOS and video buffers. The upper memory area also contains PC card memory and Intermec JANUS driver software. The 384K upper memory area maps just above 640K conventional memory.

A-16

Page 466

NF

BC Reader Specifications

A

RAM Drive Part of extended memory is configured as a RAM drive (drive E) on the 4MB JANUS device. The default CONFIG.SYS file loads HIMEM.SYS and uses the SRAMDISK.SYS device driver to create the RAM drive. You can use the RAM drive to store files just like a disk drive on your PC. File access is usually faster on a RAM drive than a physical disk drive. Unlike a PC, the JANUS device saves any files on the RAM drive during a warm boot. However, the JANUS device clears any files on the RAM drive on a cold boot. The RAM drive uses 256K of extended memory. If you are not using a PC card, Intermec recommends that you use the RAM drive for data files that you save or update frequently. The RAM drive is not as secure as a PC card since the drive is erased when you cold boot the JANUS device (unless you press during memory test).

?

Extended Memory The JANUS device is initially configured with 2.75MB of extended memory available, which is allocated for use by Intermec applications (IC.EXE and IRL). To remove the RAM drive and use the available extended memory, you need to change or delete the SRAMDISK statement in the CONFIG.SYS file. You can also use extended memory for overlay memory. The JANUS device provides extended memory for control and access to RAM above 1MB. The extended memory conforms to XMS specification 2.0. The HIMEM.SYS driver initializes and manages extended memory. HIMEM.SYS looks at all the memory in the system and takes control of everything above 1024K. You must load all drivers in extended memory through the HIMEM.SYS interface. If a driver is not compatible with HIMEM.SYS, you cannot load it in high memory. Some applications may require you to exclude memory from HIMEM.SYS management, leaving some extended memory available. If this is necessary, you should reconfigure the RAM drive (E) to use the available extended memory. DOS drivers must check in with HIMEM.SYS for their memory assignments within the XMS managed by HIMEM.SYS. Currently, the RAM drive uses the XMS interface through HIMEM.SYS.

Expanded Memory When you install more than 1MB of memory on a PC, it can be used as expanded memory and is a way for the system to access memory beyond the 1MB barrier. To use expanded memory on a PC, you need an expanded memory board and an expanded memory manager. Expanded memory is not available on 4MB JANUS devices.

A-17

Page 467

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

High Memory Area (HMA) The high memory area (HMA) is a 64K block of memory, starting 16 bytes below the 1024K mark, and is the first 64K of extended memory. Since HMA can only hold one item, the first program that requests HMA uses it, regardless of the size of the program. The DOS=HIGH statement in CONFIG.SYS loads MS-DOS into high memory.

User Flash Memory User flash memory contains the 512K ROM drive C. It is mapped to 800000H. Drive C is similar to the hard drive C on your PC and contains the MS-DOS startup files, CONFIG.SYS, and AUTOEXEC.BAT. Since drive C is a ROM drive that resides in flash memory, you cannot write files to this drive as you would on your PC. You must use the Auto-Loader or MakeDisk and PutDisk to modify the startup files or change other files on drive C.

Application Flash Memory Application flash memory is the 2MB ROM drive D. It is mapped to C00000H. DOS files and utilities are stored on drive D.

A-18

Page 468

B Reader Keypad Charts

Page 469

This page is a scan with no text; see it in the PDF.

Page 470

Reader Keypad Charts

B

This appendix provides a keypad chart that shows how to enter all characters on an alphanumeric and large numeric keypad.

Using the Reader Keypad Charts These charts list the keystroke sequences for entering all 102 PC characters or keys on the JANUS 2020’s alphanumeric (English version) and large numeric keypad.

English (U.S.) Alphanumeric Keypad Use this keypad chart to enter any character or function on the alphanumeric keypad (English version). For help, see “Using the Alphanumeric Keypad” in Chapter 2.

F6

F7 F1

~ A

F8

F2

F9

F3 {, B

+

–

– –

C

F5

I

O

}

D [

E

F

K

L

]

G

H

I

M

N

O

J P

Q

T

U

V

W

<

>

Control key Alt key

?

R /

\

S

Suspend/Resume key

F10

F4

X

Compound Function key

Caps

Y

Z home

+ pg up

&

* 8 *

(

9

^

6

7

– $

4 end

!

%

5

@

2 ins space

)

Esc

Shift key

/ pg dn enter

1 f

Alt

Ctrl

#

Viewport key

3 num lock

..

enter del

0

>

2020U.177

B-3