JANUS 2020 Hand-Held Computer (4MB) User's Manual, pages 451 to 460

Pages 451 to 460 of 565

The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec J2020, Intermec JG2020 and Intermec JR2020

Page 451

NF

BC

Page 452

NF

BC Reader Specifications

A

This appendix lists the reader’s physical and environmental specifications, and describes the types of memory available on the reader. It also lists the reader’s default configuration and provides a configuration command reference list in alphabetical order by command syntax.

Physical and Environmental Specifications You can use the tables in this section to find technical information about these features and options: • • • • • • • • • • •

Reader Dimensions Power Specifications Temperature Specifications Humidity Specifications Display Memory Data Communications Cables for Data Communications Keypad Options Symbologies Laser Scanners and Optical Parameters

Reader Dimensions Length

8.0 inches (20.3 cm)

Width

3.3 inches (8.4 cm)

Depth

2.25 inches (5.7 cm) excluding the reader handle

Weight: J2020

22.67 ounces (642.87 g) without the NiCad battery pack

JR2020

26.98 ounces (764.68 g) without the NiCad battery pack

JG2020

26.58 ounces (753.53 g) without the NiCad battery pack

Power Specifications Primary

Sealed 1500 mAh NiCad battery pack

Backup

90 mAh bridge battery

A-3

Page 453

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

Temperature Specifications You need to operate and store the reader within the temperature ranges listed in this table. Type of Operation

Fahrenheit Temperature Range

Celsius Temperature Range

Charging the battery pack

+50°F to +104°F

+10°C to +40°C

Operating the reader

-4°F to +122°F

-20°C to +50°C

-4°F to +95°F -4°F to +140°F

-20°C to +35°C -20°C to +60°C

Storing the reader With the battery pack installed Without the battery pack installed

Humidity Specifications You need to operate and store the reader within the noncondensing humidity percentages listed next. Type of Humidity

Humidity Range

Operating humidity

10% to 90% relative humidity

Storage humidity

10% to 90% relative humidity

Display •

CGA compatible

•

16 lines x 20 columns, backlit LCD display

•

25 lines by 80 columns, virtual display with viewport feature

Memory

A-4

•

512K ROM drive resident in flash memory (drive C)

•

2MB ROM (drive D)

•

4MB battery-backed RAM

•

PC card drive supports Type I and II PC cards for additional storage and I/O expansion

Page 454

NF

BC Reader Specifications

A

Data Communications •

Infrared serial communications port interface

•

RS-232C, RS-422, RS-485

•

Protocols: Multi-Drop, PC Standard, Polling Mode D, User-Defined

Cables for Data Communications Use these cables with the JL2010 Optical Link Adapter to connect the reader to a host computer or other device. Cable

PC Connector

Part Number

3-wire, null modem

DB25 port connector

047569

5-wire, null modem

DB9 port connector

059167

7-wire, null modem

DB25 port connector

048693

Use these cables with the JD2020 Communications Dock to connect the reader to a host computer or other device. Note: When you run Interlnk with the reader connected to a host computer through the communications dock, you must use a 3-wire cable. Cable

PC Connector

Part Number

3-wire, null modem

DB25 port connector

052477

3-wire, null modem

DB9 port connector

047569

7-wire, null modem

DB25 port connector

048668

7-wire, null modem

DB9 port connector

048693

Keypad Options •

Full alphanumeric keypad with 54 keys available in English, French, German, Italian, and Spanish

•

Large numeric keypad with 36 keys available in English

•

Terminal emulation keypads for IBM 3270 and 5250

A-5

Page 455

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

Symbologies • Codabar

• Code 93

• Code 11

• Code 128

• Code 16K

• Interleaved 2 of 5

• Code 2 of 5

• MSI

• Code 39

• Plessey

• Code 49

• UPC/EAN

Laser Scanners and Optical Parameters Visible laser diode (670 nm)

A-6

Bar Code Specification

Depth of Field Standard Laser Scanner

Depth of Field Long-Range Laser Scanner

7.5 mil code

3 to 7 inches

15.0 mil code

1 to 15 inches

5 to 30 inches

20.0 mil code

1 to 17 inches

5 to 40 inches

40.0 mil code

3 to 20 inches

6 to 50 inches

55.0 mil code

5 to 24 inches

12 to 60 inches

Page 456

NF

BC Reader Specifications

A

Default Configuration The next table shows the reader’s default configuration. You can use the Interactive Configuration application (IC.EXE) program to set the reader to the default configuration. For help, see “Restoring the Reader’s Default Configuration” in Chapter 5.

Bar Code Symbologies Parameter

Default

Codabar

Standard, ABCD start/stop transmitted

Code 11

Enabled with two check digits

Code 16K

Standard

Code 2 of 5

Disabled

Code 39

Full ASCII Code 39 enabled with no check digit

Code 49

Enabled, Function Codes 1 and 3 disabled, Function Code 2 set to CR LF

Code 93

Enabled

Code 128

Standard

Interleaved 2 of 5

Variable length with a check digit

MSI

Disabled

Plessey

Disabled

UPC/EAN

UPC-A/EAN-13 enabled, UPC-E and EAN-8 enabled, supplementals allowed, transmit check digit, transmit number system digit, and retain leading zero for UPC-A

Communications Parameter

Default

Address, Multi-Drop

A

AFF (Affirmative Acknowledge)

Disabled

Baud Rate

9600

Communications Dock Port

Network

Communications Port, Select COM Port

COM1

Communications Port, UART Restore

00 Hex

A-7

Page 457

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

Communications (continued)

A-8

Parameter

Default

Communications Protocol Configure Activate User-Defined Multi-Drop

Point-to-Point Point-to-Point Disabled

Data Bits

7

EOF (End of File)

Disabled

EOM (End of Message)

Transmit and receive characters set to CR and LF

EOR (End of Record)

Disabled

Flow Control

None

Intercharacter Delay

0 seconds

IRL BAK (Bad Program Acknowledge)

BEL

IRL End Program Block

SO (shift out)

IRL EOP (End of Program)

SYN (synchronous idle)

IRL PAK (Program Acknowledge)

RS (record separator)

IRL PSS (Program Statement Separator)

CR (carriage return)

IRL Run

DC2 (device control 2)

IRL SOP (Start of Program)

SI (shift in)

LRC (Longitudinal Redundancy Check)

Disabled

NEG (Negative Acknowledge)

Disabled

Parity

Even

POL (Polling)

Disabled

Records Per Block

1 record transmitted per block

REQ (Request for Acknowledge)

Disabled

RES (Reset)

Disabled

SEL (Select)

Disabled

SOM (Start of Message)

Disabled

Stop Bits

1

Timeout Delay

10 seconds

Transmit Abort Timeout

Disabled

Turnaround Delay

0 seconds

Page 458

NF

BC Reader Specifications

A

Operations Parameter

Default

Automatic Shutoff

1 minute

Beep Duration

50 milliseconds for low and high beep

Beep Frequency

1000 Hz for low beep, 2000 Hz for high beep

Beep Volume

Normal

Command Processing

All reader commands enabled

Decode Security

Moderate

Display Backlight Timeout

10 seconds

Display Contrast

3 (maximum contrast)

Display Mode, IRL

Buffered

Display Setup

25 x 80, Video mode 3, scroll at line 16, normal character height

Key Code Look-Up Table

102-key PC keyboard (no modifications)

Keypad Caps Lock

Caps lock off

Keypad Clicker

Enabled

Keypad Ctrl Key Functions

All Ctrl functions enabled

Keypad, Numeric

Permit entering numeric keypad

Postamble

<CR>

Preamble

Disabled

Scan Ahead

Disabled

Scanner Mode

One-Shot mode

Scanner Redundancy

Normal

Scanner Timeout

Disabled (no timeout)

Scanner Trigger

Level triggering

Viewport Movement Keys

Enabled

Viewport Movement Mode

Automatically follow the cursor

Viewport Movement Steps

10 horizontal steps and 9 vertical steps

A-9

Page 459

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

900 MHz RF Communications Parameter

Default

Acknowledgment Delay

100 milliseconds

Broadcast Receipt

Enabled

Channel Allow

All channels are excluded from the search pattern.

Channel Select

924 MHz

Device Address

0 (turned off)

Duty Cycle Percent

30%

Duty Cycle Period

1 second

Loopback

Disabled

Network ID

Channel search disabled

Repeat Count

0 (no repeaters)

Retry Limit

0 (optimized setting)

RF Protocol

Enabled

RFNC Address (RF Network Controller)

RFNC 0

Note: For help on the RF configuration commands, see the JANUS 900 MHz Radio Frequency Quick Reference Guide (Part No. 060207).

A-10

Page 460

NF

BC Reader Specifications

A

Configuration Commands by Syntax The next table lists all of the configuration commands that are available on the J2020 and JR2020 readers. It lists the configuration commands in alphabetic order by syntax. Note: For help on the RF configuration commands, see the JANUS 900 MHz Radio Frequency Quick Reference Guide (Part No. 060207). Syntax

Command

For Help, See Page

ADdata

Preamble

12-79

AEdata

Postamble

12-78

BDdata

Beep Duration

12-12

BFdata

Beep Frequency

12-13

BVdata

Beep Volume

12-15

CAdata

Interleaved 2 of 5 Code (I 2 of 5)

12-58

CBdata

Code 39

12-21

CCdata

Code 2 of 5 (2 of 5)

12-19

CDdata

Codabar

12-16

CEdata

UPC/EAN

12-97

CFdata

Code 93

12-27

CGdata

Code 11

12-17

CHdata

Code 128

12-28

CIdata

Plessey

12-76

CJdata

Code 49

12-25

CKdata

Code 49 Function Code 1

12-25

CLdata

Code 49 Function Code 2

12-25

CMdata

Code 49 Function Code 3

12-25

CNdata

MSI

12-72

CPdata

Code 16K

12-18

CSdata

Decode Security

12-44

DCdata

Command Processing

12-29

DFdata

Display Backlight Timeout

12-44

DJdata

Display Contrast

12-46

DMdata

Display Mode, IRL

12-47

A-11