For the Intermec J2020, Intermec JG2020 and Intermec JR2020

Page 431

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

Scan Ahead Purpose:

Enables or disables scan ahead. If you enable this parameter, you can scan a number of labels that are held in a stack until the reader can process the data. If you disable this parameter, the reader processes each label you scan before you can scan the next label.

Default:

Disabled

Syntax:

SDdata Acceptable values for data are: 0 1

Scan:

Disabled (scan one label at a time) Enabled (scan many labels at a time)

One of these bar codes: Disable Scan Ahead

*$+SD0* *$+SD0*

Enable Scan Ahead

*$+SD1* *$+SD1*

12-84

Page 432

NF

BC Configuration Command Reference

12

Scanner Mode Purpose:

Defines how the scanner operates when the trigger is pulled. There are two types of modes: •

One-Shot mode requires you to pull the trigger each time you want to scan a bar code. Once you scan a bar code, the scanner turns off.

•

Automatic mode allows you to pull the trigger once and scan a series of bar codes. When you release the trigger, the scanner turns off. To scan the same bar code more than once, you must release the trigger or scan a different bar code before attempting a second scan.

Default:

One-Shot mode

Syntax:

SBdata Acceptable values for data are: 0 1

Scan:

One-Shot mode Automatic mode

One of these bar codes: Enable One-Shot Mode

*$+SB0* *$+SB0*

Enable Automatic Mode

*$+SB1* *$+SB1*

12-85

Page 433

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

Scanner Redundancy Purpose:

Defines the number of scans (voting) the scanner takes of the same label that must decode correctly for a good read of the label. Voting allows the reader to decode the same bar code multiple times during a single-trigger event, and to compare the decoded information a specific number of times before signaling a good read. There are three options: Low Allows the reader to accept the first good read, which speeds up reader performance. This setting is recommended when scanning good quality bar codes. Normal The reader decodes the bar code a minimum number of times in each trigger event. High The reader scans and decodes the bar code a maximum number of times in each trigger event. The specific number of comparisons depends on each bar code symbology. The high setting is recommended when scanning poor quality labels that may cause substitution errors. For example, when you scan Code 39 labels and the scanner redundancy is set to normal, two successive matching decodes in a single-trigger event are required. When scanner redundancy is set to high, three successive matching decodes in a single-trigger event are required.

Default:

Normal

Syntax:

SRdata Acceptable values for data are: 0 1 2

Scan:

None Normal High

One of these bar codes: None

*$+SR0* *$+SR0* High

*$+SR2* *$+SR2*

12-86

Normal

*$+SR1*

*$+SR1*

Page 434

NF

BC Configuration Command Reference

12

Scanner Timeout Purpose:

Defines the maximum length of time the scanner stays on following each trigger pull.

Default:

Disabled (no timeout)

Syntax:

SAdata Acceptable values for data are: 0 1-60

Scan:

Disabled Shutoff time in seconds

1. Scan this bar code: Enter Accumulate Mode / Change Scanner Timeout

*+/$+SA* *+/$+SA*

2. Scan a numeric value for data from these bar codes:

*0*

*1*

*2*

*3*

*0*

*1*

*2*

*3*

*4*

*5*

*6*

*7*

*8*

*9*

*4*

*6*

*8*

*5*

*7*

*9*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-87

Page 435

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

Scanner Trigger Purpose:

Scanner trigger allows you to set level triggering or edge triggering. •

With level triggering, you pull the trigger and the laser turns on and stays on until you release the trigger.

•

In edge triggering, you pull the trigger and the laser turns on and stays on. When you pull the trigger a second time, the laser turns off. Simply releasing the trigger does not turn the laser off. If the laser is left on, the scanner timeout turns the laser off.

Default:

Level triggering

Syntax:

SCdata Acceptable values for data are: 0 1

Scan:

Level triggering Edge triggering

One of these bar codes: Enable Level Triggering

*$+SC0* *$+SC0*

Enable Edge Triggering

*$+SC1* *$+SC1*

12-88

Page 436

NF

BC Configuration Command Reference

12

SEL (Select) Purpose:

Defines the character that requests permission for the controller to send data to the polled device. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.

Default:

Disabled

Syntax:

HAdata where data can be any ASCII character.

Scan:

To disable SEL, scan this bar code: Disable SEL

*$+HA* *$+HA*

Or:

To set SEL to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set SEL

*+/$+HA* *+/$+HA*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-89

Page 437

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

SOM (Start of Message) Purpose:

SOM is the first character in a message sent to or received from the host computer. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.

Default:

Disabled

Syntax:

PEdata where data can be any ASCII character.

Scan:

To disable SOM, scan this bar code: Disable SOM

*$+PE* *$+PE*

Or:

To set SOM to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set SOM

*+/$+PE* *+/$+PE*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-90

Page 438

NF

BC Configuration Command Reference

12

Stop Bits Purpose:

Sets the number of stop bits on the communications port. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.

Default:

1 stop bit

Syntax:

ICdata Acceptable values for data are: 1 2

Scan:

1 stop bit 2 stop bits

One of these bar codes: 1 Stop Bit

*$+IC1* *$+IC1*

2 Stop Bits

*$+IC2* *$+IC2*

12-91

Page 439

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

Timeout Delay Purpose:

Defines the length of time the reader waits between characters when receiving a message. When the timeout expires, an I/O error occurs. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter. If you are using User-Defined or Point-to-Point protocol, you should only set the Timeout Delay command if the baud rate is 9600 or lower. You should disable Timeout Delay if the baud rate for either of these protocols is set to 19200 or higher.

Default:

10 sec

Syntax:

IEdata Acceptable values for data are: 0 1 2 3 4 5 6 7 8

Scan:

5 ms 100 ms 500 ms 2 sec 10 sec 20 sec 40 sec 60 sec No timeout

One of these bar codes: No Timeout Delay

*$+IE8*

*$+IE0*

*$+IE8*

*$+IE0*

Timeout Delay, 100 ms

Timeout Delay, 500 ms

*$+IE1*

*$+IE2*

*$+IE1*

12-92

Timeout Delay, 5 ms

*$+IE2*

Page 440

NF

BC Configuration Command Reference

12

Timeout Delay (continued) Timeout Delay, 2 sec

Timeout Delay, 10 sec

*$+IE3*

*$+IE4*

Timeout Delay, 20 sec

Timeout Delay, 40 sec

*$+IE3*

*$+IE5* *$+IE5*

*$+IE4*

*$+IE6*

*$+IE6*

Timeout Delay, 60 sec

*$+IE7* *$+IE7*

Transmit Abort Timeout Purpose:

Defines the length of time the reader waits to receive a message if one of these conditions is true: •

CTS is continuously false for the timeout period.

•

XOFF condition does not change within the timeout period.

•

POL not received (polling protocol) within the timeout period.

Transmit Abort Timeout is similar to the Timeout Delay configuration, but it only applies to the three conditions listed above. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter. Default:

Disabled

Syntax:

IHdata Acceptable values for data are: 0 1-65000

Scan:

Disabled Timeout in ms

To disable Transmit Abort Timeout, scan this bar code: Disable Transmit Abort Timeout

*$+IH0* *$+IH0*

12-93