Page 421

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

NEG (Negative Acknowledge) Purpose:

Indicates a negative acknowledgment to a transmitted message. You must enable both NEG and AFF to have a valid configuration. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.

Default:

Disabled

Syntax:

PHdata where data can be any ASCII character.

Scan:

To disable NEG, scan this bar code: Disable NEG

*$+PH* *$+PH*

Or:

To set NEG to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set NEG

*+/$+PH* *+/$+PH*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-74

Page 422

NF

BC Configuration Command Reference

12

Parity Purpose:

Sets the parity of the selected communications port. The reader uses parity for error checking in data transmissions. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.

Default:

Even

Syntax:

IBdata Acceptable values for data are: 0 1 2 3 4

Scan:

No parity Even parity Odd parity Mark parity Space parity

One of these bar codes: No Parity

Even Parity

*$+IB0*

*$+IB1*

Odd Parity

Mark Parity

*$+IB0*

*$+IB2* *$+IB2*

*$+IB1*

*$+IB3*

*$+IB3*

Space Parity

*$+IB4* *$+IB4*

12-75

Page 423

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

Plessey Purpose:

Enables or disables decoding of Plessey symbology. Plessey code is pulse-width modulated. It includes a start character, data characters, an eight-bit cyclic check digit, a termination bar, and usually a reverse start character. The code is continuous and not self-checking. You need to configure two parameters for Plessey code: Start Code and Check Digit.

Default:

Disabled

Syntax:

CIdata Acceptable values for data are: 00 10 30 31

Scan:

Disabled Plessey with reverse start code Transmit check digit Discard check digit

To disable Plessey: Disable Plessey

*$+CI00* *$+CI00*

Or:

To set Plessey, complete these steps: 1. Scan this bar code: Plessey With Reverse Start Code

*$+CI10* *$+CI10*

2. Scan one of these bar codes to transmit or retain the check digit: Transmit Check Digit

*$+CI30* *$+CI30*

12-76

Discard Check Digit

*$+CI31*

*$+CI31*

Page 424

NF

BC Configuration Command Reference

12

POL Purpose:

Solicits or requests data from a polled device. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.

Default:

Disabled

Syntax:

HBdata where data can be any ASCII character.

Scan:

To disable POL, scan this bar code: Disable POL

*$+HB* *$+HB*

Or:

To set POL to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set POL

*+/$+HB* *+/$+HB*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-77

Page 425

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

Postamble Purpose:

Sets the postamble that is appended to any data you scan with the reader. Common postambles include cursor controls such as tabs or carriage return line feeds. Note: A postamble is not added to scanned data when you run IRL programs.

Default:

<CR>

Syntax:

AEdata Acceptable values for data are up to 25 ASCII characters. If you enter the AE command without data, the postamble is disabled. You must enclose the data within quotation marks if the data is a reserved word, such as a reader configuration command (see the example).

Scan:

To disable the postamble, scan this bar code: Disable Postamble

*$+AE* *$+AE*

Or:

To set the postamble to an ASCII character string: 1. Scan this bar code: Enter Accumulate Mode / Set Postamble

*+/$+AE* *+/$+AE*

2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix C. The postamble can be from 1 to 25 characters. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-78

Page 426

NF

BC Configuration Command Reference

12

Postamble (continued) Example:

You want to set the postamble to the letters “BV,” which also represents the Beep Volume configuration command. Enter the postamble by scanning this bar code: Set Postamble to BV

*$+AE/BBV/B* $+AE"BV"

If you omit the quotation marks, the reader interprets the command as two commands: AE to set the postamble to no characters, and BV to change the beep volume.

Preamble Purpose:

Sets the preamble that precedes any data you scan with the reader. Common preambles include a data location number or an operator number. Note: A preamble is not added to scanned data when you run IRL programs.

Default:

Disabled

Syntax:

ADdata Acceptable values for data are up to 25 ASCII characters. When you enter the AD command without data, the preamble is disabled. You must enclose the data within quotation marks if the data is a reserved word, such as a reader configuration command (see the example at the end of this section).

Scan:

To disable the preamble, scan this bar code: Disable Preamble

*$+AD* *$+AD*

Or:

To set the preamble to an ASCII character string: 1. Scan this bar code: Enter Accumulate Mode / Set Preamble

*+/$+AD* *+/$+AD*

12-79

Page 427

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

Preamble (continued) 2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix C. The preamble can be from 1 to 25 characters. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Example:

You want to set the preamble to the letters “BV,” which also represents the Beep Volume configuration command. Enter the preamble by scanning this bar code: Set Preamble to BV

*$+AD/BBV/B* $+AD"BV"

If you omit the quotation marks, the reader interprets the command as two commands: AD to set the preamble to no characters, and BV to change the beep volume.

Records Per Block Purpose:

Defines the maximum number of data records transmitted per block of data. Usually files are transmitted record by record. This configuration allows you to transmit multiple records per data block. A block of data is transmitted during a single transmission, like an individual data record is normally. Note: The configured option may be overridden when you use certain communications protocols. Records Per Block will not be overridden when you use User-Defined protocol. You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.

Default:

12-80

1 record transmitted per block

Page 428

NF

BC Configuration Command Reference

12

Records Per Block (continued) Syntax:

FCdata Acceptable values for data are: 0 01-99

Scan:

All records are transmitted in one block Records transmitted per block

To have all records transmitted in one block, scan this bar code: All Records = 1 Block

*$+FC0* *$+FC0*

Or:

To set the records per block: 1. Scan this bar code: Enter Accumulate Mode / Set Number of Records Per Block

*+/$+FC* *+/$+FC*

2. Scan a two-digit numeric value for data from these bar codes:

*0* *0*

*2*

*1* *1*

*3*

*2*

*3*

*4*

*5*

*6*

*7*

*8*

*9*

*4*

*6*

*8*

*5*

*7*

*9*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-81

Page 429

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

REQ (Request for Acknowledge) Purpose:

Enables or disables a request for a repeat handshake event. If you enable REQ, you must also enable AFF and NEG to have a valid configuration. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.

Default:

Disabled

Syntax:

PDdata where data can be any ASCII character.

Scan:

To disable REQ, scan this bar code: Disable REQ

*$+PD* *$+PD*

Or:

To set REQ to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set REQ

*+/$+PD* *+/$+PD*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-82

Page 430

NF

BC Configuration Command Reference

12

RES (Reset) Purpose:

Enables or disables a reset event. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.

Default:

Disabled

Syntax:

PCdata where data can be any ASCII character.

Scan:

To disable RES, scan this bar code: Disable RES

*$+PC* *$+PC*

Or:

To set RES to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set RES

*+/$+PC* *+/$+PC*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-83