The text of a manual · part 41 of 57
JANUS 2020 Hand-Held Computer (4MB) User's Manual, pages 401 to 410
Pages 401 to 410 of 565
The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec J2020, Intermec JG2020 and Intermec JR2020
Page 401
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
EOM (continued) 2. Scan one or two bar codes for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Or:
To set EOM Transmit and Receive to different ASCII characters: Note: You can enable an EOM Transmit character and disable the EOM Receive character, or vice versa. 1. Scan this bar code to set the EOM Transmit character: Enter Accumulate Mode / Enable EOM Transmit Only
*+/$+PI* *+/$+PI*
2. Scan one or two bar codes for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
4. Scan this bar code to set the EOM Receive character: Enter Accumulate Mode / Enable EOM Receive Only
*+/$+PJ* *+/$+PJ*
5. Scan one or two bar codes for data from the “Full ASCII Bar Code Chart” in Appendix C. 6. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-54
Page 402
NF
BC Configuration Command Reference
12
EOR (End of Record) Purpose:
Attaches an EOR to the end of every record of a file transmit. Note: You must select the communications port and protocol before you set the parameters to define that protocol. For help, see “Communications Protocol, Configure” earlier in this chapter. The configured option may be overridden when you use certain communications protocols. EOR will not be overridden when you use User-Defined protocol.
Default:
Disabled
Syntax:
FBdata where data can be one or two ASCII characters.
Scan:
To disable EOR, scan this bar code: Disable EOR
*$+FB* *$+FB*
Or:
To set the EOR character to an ASCII character(s): 1. Scan this bar code: Enter Accumulate Mode / Set EOR
*+/$+FB* *+/$+FB*
2. Scan one or two bar codes for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-55
Page 403
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
Flow Control Purpose:
Regulates the data transmission through the communications port. The reader is a DTE device. Clear To Send/Request To Send (CTS/RTS) is a hardware signal flow control. The reader sets RTS high when it is ready to transmit. The reader checks CTS when it tries to transmit data. XON/XOFF response causes the reader to respond to XON/XOFF characters received while transmitting. XON/XOFF control specifies that the reader transmits XON/XOFF characters to control the incoming data flow. XON/XOFF response and control specify that the reader responds to and transmits XON/XOFF characters. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.
Default:
None
Syntax:
ILdata Acceptable values for data are: 0 1 2 3 4
Scan:
None CTS checking/RTS control XON/XOFF response XON/XOFF control XON/XOFF response and control
One of these bar codes: No Flow Control
CTS Checking/RTS Control
*$+IL0*
*$+IL1*
XON/XOFF Response
XON/XOFF Control
*$+IL0*
*$+IL2* *$+IL2*
XON/XOFF Response and Control
*$+IL4* *$+IL4*
12-56
*$+IL1*
*$+IL3*
*$+IL3*
Page 404
NF
BC Configuration Command Reference
12
Intercharacter Delay Purpose:
Defines the amount of time the reader waits before sending each character to the host. It modifies outgoing data only by slowing the speed of transmission. A character delay can be useful when the reader is communicating with a controller through a modem using full-duplex operation. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.
Default:
0 sec
Syntax:
IDdata Acceptable values for data are: 0 1 2 3 4 5 6 7
Scan:
0 ms 1 ms 2 ms 5 ms 10 ms 20 ms 50 ms 100 ms
One of these bar codes: Intercharacter Delay, 0 ms
*$+ID0*
Intercharacter Delay, 1 ms
*$+ID1*
*$+ID0*
*$+ID1*
Intercharacter Delay, 2 ms
Intercharacter Delay, 5 ms
*$+ID2*
*$+ID3*
*$+ID2*
*$+ID3*
Intercharacter Delay, 10 ms
Intercharacter Delay, 20 ms
*$+ID4*
*$+ID5*
Intercharacter Delay, 50 ms
Intercharacter Delay, 100 ms
*$+ID4*
*$+ID6* *$+ID6*
*$+ID5*
*$+ID7*
*$+ID7*
12-57
Page 405
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
Interleaved 2 of 5 Purpose:
Enables or disables decoding of Interleaved 2 of 5 (I 2 of 5) symbology. I 2 of 5 is a high-density, self-checking, continuous numeric symbology. It is mainly used in inventory distribution and the automobile industry. Enabling I 2 of 5 automatically disables Code 2 of 5.
Default:
Variable length with a check digit
Syntax:
CAdata Acceptable values for data are: 0 2-32 97 98 99
Disabled Fixed length (even number only) Variable length without a check digit Case code (6 or 14) with a check digit Variable length with a check digit
Caution Using the variable length without a check digit configuration option can cause substitution errors. Conseil Des erreurs de substitution peuvent survenir si vous utilisez la longueur variable sans option de vérification de configuration de chiffres. Scan:
One of these bar codes: Disable Interleaved 2 of 5
*$+CA0* *$+CA0*
Enable Variable Length Without a Check Digit
*$+CA97* *$+CA97*
Enable Variable Length With a Check Digit
*$+CA99* *$+CA99*
12-58
Page 406
NF
BC Configuration Command Reference
12
Interleaved 2 of 5 (continued) Enable Interleaved 2 of 5, Case Code
*$+CA98* *$+CA98*
Or:
To set Interleaved 2 of 5 to a fixed length: 1. Scan this bar code: Enter Accumulate Mode / Set Fixed Length
*+/$+CA* *+/$+CA*
2. Scan a numeric value for data from these bar codes. (Use even numbers 2-32 only)
*0*
*1*
*2*
*3*
*0*
*1*
*2*
*3*
*4*
*6*
*4*
*6*
*8* *8*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-59
Page 407
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
IRL BAK (Bad Program Acknowledge) Purpose:
The reader sends a BAK to indicate that it cannot successfully download an IRL program. Note: You must select the communications port and protocol before you set the parameters to define that protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.
Default:
BEL
Syntax:
ZBdata where data can be any ASCII character.
Scan:
To disable BAK, scan this bar code: Disable BAK
*$+ZB* *$+ZB*
Or:
To set BAK to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set BAK
*+/$+ZB* *+/$+ZB*
2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-60
Page 408
NF
BC Configuration Command Reference
12
IRL End Program Block Purpose:
Indicates the last block of an IRL program when you download a program to the reader. Note: You must select the communications port and protocol before you set the parameters to define that protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.
Default:
SO (shift out)
Syntax:
XDdata where data can be any ASCII character.
Scan:
To disable IRL End Program Block, scan this bar code: Disable IRL End Program Block
*$+XD* *$+XD*
Or:
To set IRL End Program Block to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / IRL End Program Block
*+/$+XD* *+/$+XD*
2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-61
Page 409
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
IRL EOP (End of Program) Purpose:
An EOP indicates the end of an IRL program block when you download a program to the reader. Note: You must select the communications port and protocol before you set the parameters to define that protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.
Default:
SYN (synchronous idle)
Syntax:
XBdata where data can be any ASCII character.
Scan:
To disable EOP, scan this bar code: Disable EOP
*$+XB* *$+XB*
Or:
To set EOP to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set EOP
*+/$+XB* *+/$+XB*
2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-62
Page 410
NF
BC Configuration Command Reference
12
IRL PAK (Program Acknowledge) Purpose:
The reader sends this character to the host computer to acknowledge an IRL program that it has received. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.
Default:
RS (record separator)
Syntax:
ZAdata where data can be any ASCII character.
Scan:
To disable PAK, scan this bar code: Disable PAK
*$+ZA* *$+ZA*
Or:
To set the PAK to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set PAK
*+/$+ZA* *+/$+ZA*
2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-63