Page 391
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
Decode Security Purpose:
Defines the security level to use when decoding bar codes. When you select a lower decode security level, the reader can decode bar codes with poorer print quality. Note: Only use the low parameter as a temporary solution until you can improve the bar code label print quality.
Default:
Moderate
Syntax:
CSdata Acceptable values for data are: 0 1 2
Scan:
Low Moderate High
One of these bar codes: Low Decode Security
*$+CS0* *$+CS0*
Moderate Decode Security
*$+CS1* *$+CS1*
High Decode Security
*$+CS2* *$+CS2*
Display Backlight Timeout Purpose:
Defines the amount of time the backlight remains on. The backlight timeout setting significantly affects the reader’s battery life. If you set a longer backlight timeout value, you will use the power in the NiCad battery pack at a faster rate.
Default:
10 seconds
12-44
Page 392
NF
BC Configuration Command Reference
12
Display Backlight Timeout (continued) Syntax:
DFdata Acceptable values for data are: 00 01- 60
Scan:
Disabled Timeout in seconds
To disable the backlight timeout, scan this bar code: Disable Backlight Timeout
*$+DF00* *$+DF00*
Or:
To set the backlight timeout: 1. Scan this bar code: Enter Accumulate Mode / Set Backlight Timeout
*+/$+DF* *+/$+DF*
2. Scan a two-digit numeric value for data from these bar codes.
*0* *0*
*2*
*1* *1*
*3*
*2*
*3*
*4*
*5*
*6*
*7*
*8*
*9*
*4*
*6*
*8*
*5*
*7*
*9*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-45
Page 393
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
Display Contrast Purpose:
Defines the contrast (light or dark) of the characters against the reader display.
Default:
3 (maximum contrast)
Syntax:
DJdata Acceptable values for data are 0 (light) to 7 (dark).
Scan:
One of these bar codes: 0 - Light
*$+DJ0*
*$+DJ1*
*$+DJ0*
*$+DJ1*
2
3 - Maximum Contrast
*$+DJ2*
*$+DJ3*
*$+DJ2*
*$+DJ3*
4
5
*$+DJ4*
*$+DJ5*
6
7 - Dark
*$+DJ6*
*$+DJ7*
Lighter
Darker
*$+DJ8*
*$+DJ9*
*$+DJ4*
*$+DJ6*
*$+DJ8*
12-46
1
*$+DJ5*
*$+DJ7*
*$+DJ9*
Page 394
NF
BC Configuration Command Reference
12
Display Mode, IRL Purpose:
Determines how IRL displays and handles data. The reader has two IRL display modes: buffered and transparent. Buffered display A buffered display formats the display text with a full block character and a Carriage Return Line Feed (CR LF) after each data record. When you run an IRL program, the CR LF is actually executed before the next IRL prompt. Transparent display A transparent display does not add a CR LF after each data record. Scanned data records are concatenated together. Autowrap and autoscroll features are disabled. When the cursor gets to the end of a line, it does not wraparound. When the cursor reaches the bottom of the display, it does not scroll up. You must include control codes in the IRL program to format the display and move the cursor around. For example, you can use a CR LF sequence to move down one display line or to scroll the display after the last line. Error messages are not displayed.
Default:
Buffered
Syntax:
DMdata Acceptable values for data are: 0 1
Scan:
Buffered Transparent
One of these bar codes: Buffered Display Mode
*$+DM0* *$+DM0*
Transparent Display Mode
*$+DM1* *$+DM1*
12-47
Page 395
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
Display Setup Purpose:
Defines the number of lines and columns in the display image, the Video mode, at what line the display scrolls, and the character height. The reader’s video modes are used in the same way as on a PC. The reader’s display size is 16 lines or rows by 20 characters. You can use the display as a viewport to the reader’s virtual display of 25 lines by 80 characters. If you select the 25 x 80 display size, you can set the Video mode, character height, and scroll line; otherwise, those parameters are preset to match the display size. For help, see “How to Use the Reader’s Display” in Chapter 2. Note: If you are working at the DOS prompt, Intermec recommends that you set the display size to 25 x 80 or you may see inconsistent display results. While you run an application, the reader reverts to Automatic Viewport Movement mode and scrolls at line 25 unless your application sets these values. When you exit the application, the reader restores your previous configuration values.
Default:
First digit: Second digit: Third digit: Fourth digit:
Syntax:
DSdata
Display size 25 lines by 80 characters (25 x 80) Video mode 3 (normal character width, Color mode) Scrolls at line 16 Normal character height
Acceptable values for data are four digits corresponding to: First digit:
0 1 2 3 4
25 x 80 (lines by characters) 16 x 20 8 x 20 16 x 10 8 x 10
Second digit:
0 1 2 3
Video mode 0 (double character width, monochrome) Video mode 1 (double character width, color) Video mode 2 (normal character width, monochrome) Video mode 3 (normal character width, color)
Third digit:
0 1 2
Scroll at line 25 Scroll at line 16 Scroll at line 8
Fourth digit:
0 1
Normal character height Double character height
Note: The JANUS reader display is a monochrome display. In Color Video mode, the display supports gray scales. Existing applications may have a more readable display by using either Monochrome or Color mode.
12-48
Page 396
NF
BC Configuration Command Reference
12
Display Setup (continued) Scan:
One of these bar codes to set the display options:
@
Note: When you scan a label that changes the Video mode, the screen goes blank. To if you are at the DOS prompt. activate the screen, begin entering data or press 25 x 80, Video Mode 2, Scroll at Line 25, Normal Character Height
*$+DS0200* *$+DS0200*
25 x 80, Video Mode 2, Scroll at Line 25, Double Character Height
*$+DS0201* *$+DS0201*
25 x 80, Video Mode 2, Scroll at Line 16, Normal Character Height
*$+DS0210* *$+DS0210*
25 x 80, Video Mode 2, Scroll at Line 8, Double Character Height
*$+DS0221* *$+DS0221*
25 x 80, Video Mode 3, Scroll at Line 25, Normal Character Height
*$+DS0300* *$+DS0300*
25 x 80, Video Mode 3, Scroll at Line 25, Double Character Height
*$+DS0301* *$+DS0301*
25 x 80, Video Mode 3, Scroll at Line 16, Normal Character Height
*$+DS0310* *$+DS0310*
25 x 80, Video Mode 3, Scroll at Line 8, Double Character Height
*$+DS0321* *$+DS0321*
12-49
Page 397
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
Display Setup (continued) 25 x 40, Video Mode 0, Scroll at Line 25, Normal Character Height
*$+DS0000* *$+DS0000*
25 x 40, Video Mode 0, Scroll at Line 25, Double Character Height
*$+DS0001* *$+DS0001*
25 x 40, Video Mode 0, Scroll at Line 16, Normal Character Height
*$+DS0010* *$+DS0010*
25 x 40, Video Mode 0, Scroll at Line 8, Double Character Height
*$+DS0021* *$+DS0021*
25 x 40, Video Mode 1, Scroll at Line 25, Normal Character Height
*$+DS0100* *$+DS0100*
25 x 40, Video Mode 1, Scroll at Line 25, Double Character Height
*$+DS0101* *$+DS0101*
25 x 40, Video Mode 1, Scroll at Line 16, Normal Character Height
*$+DS0110* *$+DS0110*
25 x 40, Video Mode 1, Scroll at Line 8, Double Character Height
*$+DS0121* *$+DS0121*
16 x 20 (lines by characters)
*$+DS1* *$+DS1*
12-50
Page 398
NF
BC Configuration Command Reference
12
Display Setup (continued) 8 x 20 (lines by characters)
*$+DS2* *$+DS2*
16 x 10 (lines by characters)
*$+DS3* *$+DS3*
8 x 10 (lines by characters)
*$+DS4* *$+DS4*
12-51
Page 399
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
EOF (End of File) Purpose:
Defines the end of file character for the communications port when transmitting a file from the reader. Note: You must select the communications port and protocol before you set the parameters to define that protocol. For help, see “Communications Protocol, Configure” earlier in this chapter. The configured option may be overridden when you use certain communications protocols. The EOF will not be overridden when you use User-Defined protocol.
Default:
Disabled
Syntax:
FAdata where data can be any ASCII character.
Scan:
To disable EOF, scan this bar code: Disable EOF
*$+FA* *$+FA*
Or:
To set EOF to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set EOF
*+/$+FA* *+/$+FA*
2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-52
Page 400
NF
BC Configuration Command Reference
12
EOM (End of Message) Purpose:
Attaches an EOM to the end of a data block to indicate the end of data transmission to and from a reader. You can disable the EOM transmit and receive characters, define EOM transmit and receive to the same characters, or define EOM transmit and receive to different characters. Note: You must select the communications port and protocol before you set the parameters to define that protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.
Default:
EOM Transmit and Receive are set to CR (0DH) and LF (0AH) (carriage return line feed)
Syntax:
PF PFdata
Disable EOM transmit and receive Enable EOM transmit and receive
PI PIdata
Disable EOM transmit only Enable EOM transmit only
PJ PJdata
Disable EOM receive only Enable EOM receive only where data can be one or two ASCII characters. Scan:
To disable EOM, scan one of these bar codes: Disable EOM Transmit and Receive
*$+PF* *$+PF*
Disable EOM Transmit Only
*$+PI*
*$+PI*
Disable EOM Receive Only
*$+PJ* *$+PJ*
Or:
To set EOM Transmit and Receive to the same ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Enable EOM Transmit and Receive
*+/$+PF* *+/$+PF*
12-53