The text of a manual · part 38 of 57
JANUS 2020 Hand-Held Computer (4MB) User's Manual, pages 371 to 380
Pages 371 to 380 of 565
The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec J2020, Intermec JG2020 and Intermec JR2020
Page 371
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
Code 39 (continued) 3. Scan one of these bar codes to set the second digit: Discard Check Digit
Transmit Check Digit
*0*
*1*
*0*
*1*
4. Scan one of these bar codes to set the third digit: Code 39 Non-Full ASCII
Code 39 Full ASCII
*0*
*1*
*0*
Code 39 Mixed-Full ASCII
*2* *2*
5. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-24
*1*
Page 372
NF
BC Configuration Command Reference
12
Code 49 Purpose:
Enables or disables decoding of Code 49 symbology. Code 49 is a multirow symbology for high data density. The last character in each row is used for row checking and the last two characters of the symbol are used for overall checking. Function codes designate where to place the predefined data string in a Code 49 label. Whenever a reader encounters a function code, it replaces the function code with the defined string before transmitting the data to the workstation. A single Code 49 symbol may contain several different variable length data fields. Function Code 1 (F1) identifies a data system. Function Code 2 (F2) indicates the end of a data field.
Default:
Code 49 Enabled, Function Code 1 disabled, Function Code 2 set to CR LF, and Function Code 3 disabled.
Syntax:
CJdata CKdata CLdata CMdata
Code 49 Function Code 1 Function Code 2 Function Code 3
Acceptable values for data are:
Scan:
Code 49:
0 1
Function Code 1:
Any two ASCII characters.
Function Code 2:
Any four ASCII characters
Function Code 3:
Any two ASCII characters
One of these bar codes: Disable Code 49
Enable Code 49
*$+CJ0*
*$+CJ1*
*$+CJ0*
Scan:
Disabled Enabled
*$+CJ1*
To disable any of the function codes, scan one of these bar codes: Disable Function Code 1
Disable Function Code 2
*$+CK*
*$+CL*
*$+CK*
*$+CL*
12-25
Page 373
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
Code 49 (continued) Disable Function Code 3
*$+CM* *$+CM*
Or:
To set one of the function codes to a character string: 1. Scan one of these bar codes: Enter Accumulate Mode / Set Function Code 1
*+/$+CK* *+/$+CK*
Enter Accumulate Mode / Set Function Code 2
*+/$+CL* *+/$+CL*
Enter Accumulate Mode / Set Function Code 3
*+/$+CM* *+/$+CM*
2. Scan any character from the “Full ASCII Bar Code Chart” in Appendix C. You can define two characters each for Function Codes 1 and 3, and four characters for Function Code 2. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-26
Page 374
NF
BC Configuration Command Reference
12
Code 93 Purpose:
Enables or disables decoding of Code 93 symbology. Code 93 is a variable length, continuous symbology that uses four element widths. It complements Code 39.
Default:
Enabled
Syntax:
CFdata Acceptable values for data are: 0 1
Scan:
Disabled Enabled
One of these bar codes: Disable Code 93
*$+CF0* *$+CF0*
Enable Code 93
*$+CF1* *$+CF1*
12-27
Page 375
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
Code 128 Purpose:
Enables or disables decoding of Code 128 symbology. Code 128 is a very high density alphanumeric symbology that supports the extended ASCII character set. It is a variable length, continuous code that uses multiple element widths.
Default:
Standard
Syntax:
CHdata Acceptable values for data are: 0 1 2
Scan:
Disabled Standard Code 128 UCC/EAN Code 128
One of these bar codes: Disable Code 128
*$+CH0* *$+CH0*
Enable Standard Code 128
*$+CH1* *$+CH1*
Enable UCC/EAN Code 128
*$+CH2* *$+CH2*
Notes:
If you configure Standard Code 128, the reader will not decode Function Code 1 characters in the first position of a bar code label. Any subsequent Function Code 1 characters are translated to the ASCII GS character as a separator for variable length fields. If you configure UCC/EAN Code 128, the reader will decode a bar code label as Standard Code 128 unless the first two characters are a start character and a Function Code 1. If the first two characters are a start character and a Function Code 1: 1. The Function Code 1 character is not transmitted. 2. The three symbology ID characters, ]C1, are transmitted. 3. The remaining Code 128 characters are decoded as Standard Code 128.
12-28
Page 376
NF
BC Configuration Command Reference
12
Command Processing Purpose:
Command processing allows you to disable or enable reader commands. For example, you can disable the Backlight command. There are two ways to enable or disable reader commands: •
Use the Command Processing configuration command described here.
•
Use the Reader Commands option on the Op menu in the Interactive Configuration application (IC.EXE) program.
If you want to disable or enable several commands, it is easier to use IC.EXE. For help, see Chapter 5, “Configuring the Reader.” Default:
All reader commands enabled
Syntax:
DCdata Acceptable values for data are: 0 1 2 3 command0 command1
Disable all reader commands Enable all reader commands Disable override Enable override Disable reader command Enable reader command
The override option is a temporary setting that allows you to enable all the reader commands for as long as you need them. When you want to return to the previous setting, you disable the override. Note: If you disable all the reader commands ($+DC0), you cannot change the reader’s configuration or exit from an IRL program. To enable the reader commands again, use IC.EXE, or edit the configuration “*.ini” file. Scan:
To enable all the reader commands or override the current settings, scan one of these bar codes: Disable All Reader Commands
Enable All Reader Commands
*$+DC0*
*$+DC1*
Disable Override
Enable Override
*$+DC0*
*$+DC2* *$+DC2*
*$+DC1*
*$+DC3*
*$+DC3*
12-29
Page 377
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
Command Processing (continued) Or:
To disable or enable specific reader commands, perform these steps: 1. Scan this bar code: Enter Accumulate Mode / Command Processing
*+/$+DC* *+/$+DC*
2. Scan the bar code to disable or enable one reader command. Note: If there are two bar codes for a reader command, you must scan them in order, left to right. Backspace
*-*
*+*
*-*
*+*
Backlight
Change Configuration
*%.*
*$+*
*%.*
*$+*
Clear
(continued)
*-*
*-*
Enter Accumulate Mode
(continued)
*-*
*+*
*-*
*/*
*+*
*/*
Exit Accumulate Mode
(continued)
*-*
*/*
*-*
*/*
IRL File, Clear
IRL File, Receive
*.$*
*.%*
*.$*
12-30
(continued)
*.%*
Page 378
NF
BC Configuration Command Reference
12
Command Processing (continued) IRL File, Transmit
IRL Program, Download
*%%*
*$O*
*%%*
*<SI>*
IRL Program, Exit
(continued)
*/*
*$*
IRL Program, Resume
IRL Program, Run
*/*
*$.*
*/*
*/*
*$.*
*//*
Laser Off
Laser On
*/%*
*/.*
Viewport Down
Viewport Up
*%+*
*%/*
Viewport Left
Viewport Right
*%-*
*.-*
Viewport End
Viewport Home
*/%*
*%+*
*%-*
*..%.*
*/.*
*%/*
*.-*
*..%/*
*..%.*
*..%/*
Viewport Page Down
Viewport Page Up
*..%-*
*..%+*
*..%-*
*..%+*
Viewport to Cursor
Cursor to Viewport
*/-*
*..%%*
*/-*
*..%%*
12-31
Page 379
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
Command Processing (continued) Alternate Key Code Entry
Multiple-Read Labels
*..*
* *
*..*
* *
Prepare for Reboot
Reboot
*..+%*
*..%$*
*..+%*
*..%$ *
Set Clock
*/+* */+*
Note: To disable or enable Command Override or the Enter key, see the next section, “Disabling or Enabling Command Override and Enter.” 3. Scan one of these bar codes: Disable the Command
Enable the Command
*0*
*1*
*0*
*1*
4. Repeat Steps 2 and 3 to disable or enable another reader command. Note: You can accumulate up to 250 characters in the buffer. If the data accumulated exceeds 250 characters, you will hear an error beep and the reader will reject the last bar code read. 5. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-32
Page 380
NF
BC Configuration Command Reference
12
Disabling or Enabling Command Override and Enter Purpose:
You can use the Command Processing configuration command to disable or enable two additional reader commands: Command Override and Enter. You can also use IC.EXE to disable or enable these two commands. For help, see Chapter 5, “Configuring the Reader.”
Default:
Command Override and Enter enabled
Syntax:
DC<command>data Acceptable values for data are: 0 1
Scan:
Disable command Enable command
To disable or enable Command Override, scan one of these bar codes: Disable Command Override
*/D/KDC$P0* *$+DC<DLE>0*
Enable Command Override
*/D/KDC$P1* *$+DC<DLE>1*
Or:
To disable or enable Enter, scan one of these bar codes: Disable Enter
*/D/KDC$M0* *$+DC<CR>0* Enable Enter
*/D/KDC$M1* *$+DC<CR>1*
12-33