The text of a manual · part 37 of 57
JANUS 2020 Hand-Held Computer (4MB) User's Manual, pages 361 to 370
Pages 361 to 370 of 565
The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec J2020, Intermec JG2020 and Intermec JR2020
Page 361
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
Beep Frequency (continued) Scan:
1. Scan this bar code: Enter Accumulate Mode / Change Beep Frequency
*+/$+BF* *+/$+BF*
2. Scan a numeric value for data in Hz from these bar codes:
*0*
*1*
*2*
*3*
*0*
*1*
*2*
*3*
*4*
*5*
*6*
*7*
*8*
*9*
*4*
*6*
*8*
*5*
*7*
*9*
3. Scan one of these bar codes to set the frequency for the low or high beep: Low Beep
*L* *L*
4. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-14
High Beep
*H*
*H*
Page 362
NF
BC Configuration Command Reference
12
Beep Volume Purpose:
Adjusts the volume of the reader’s audio signals. For a list of all the beep sounds and audio signals, see “Understanding the Reader’s Audio Signals” in Chapter 2. Set the beep volume according to operator preference and work environment.
Default:
Normal
Syntax:
BVdata Acceptable values for data are: 0 1 2 3 4 8 9
Scan:
Off Quiet Normal Loud Very loud Lower volume Raise volume
One of these bar codes: Off
Quiet
*$+BV0*
*$+BV1*
Normal
Loud
*$+BV0*
*$+BV2* *$+BV2*
*$+BV1*
*$+BV3*
*$+BV3*
Very Loud
*$+BV4* *$+BV4*
Or:
Scan one of these bar codes repeatedly to achieve the desired volume: Raise Beep Volume
*$+BV9* *$+BV9*
Lower Beep Volume
*$+BV8*
*$+BV8*
12-15
Page 363
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
Codabar Purpose:
Enables or disables decoding of Codabar symbology. Codabar is a self-checking, discrete symbology that has these 16 characters in its set: 0 to 9, dollar sign ($), colon (:), slash (/), period (.), plus (+), and minus (-). Codabar is commonly used in libraries, blood banks, and air-parcel express applications. The American Blood Commission (ABC) Codabar requires that you retain the start/stop code digits when processing a Codabar symbol. As a result, configuration CD10 is an illegal configuration.
Default:
Standard Codabar, ABCD Start/Stop Transmitted
Syntax:
CDdata Acceptable values for data must be two digits, corresponding to:
Scan:
Digit
Value
Description
First
0 1 2 3
Disabled ABC Standard Concatenated
Second
0 1 2
Discard Start/Stop ABCD Enabled, Start/Stop Transmitted DC1-DC4 Enabled, Start/Stop Transmitted
One of these bar codes: Disabled, Discard Start/Stop
ABC, ABCD Start/Stop
*$+CD00*
*$+CD11*
ABC, DC1-DC4 Start/Stop
Standard, Discard Start/Stop
*$+CD00*
*$+CD12*
*$+CD20*
*$+CD12*
*$+CD20*
Standard, ABCD Start/Stop
Standard, DC1-DC4 Start/Stop
*$+CD21* *$+CD21*
12-16
*$+CD11*
*$+CD22*
*$+CD22*
Page 364
NF
BC Configuration Command Reference
12
Codabar (continued) Concatenated, Discard Start/Stop
Concatenated, ABCD Start/Stop
*$+CD30*
*$+CD31*
*$+CD30*
*$+CD31*
Concatenated, DC1-DC4 Start/Stop
*$+CD32* *$+CD32*
Code 11 Purpose:
Enables or disables decoding of Code 11 symbology. Code 11 is a very high density, discrete numeric bar code. It is most extensively used in labeling telecommunications components and equipment.
Default:
Enabled with two check digits
Syntax:
CGdata Acceptable values for data are: 0 1 2
Scan:
Disabled Code 11 enabled with one check digit Code 11 enabled with two check digits
One of these bar codes: Disable Code 11
*$+CG0* *$+CG0*
Code 11 Enabled With One Check Digit
*$+CG1* *$+CG1*
Code 11 Enabled With Two Check Digits
*$+CG2* *$+CG2*
12-17
Page 365
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
Code 16K Purpose:
Enables or disables decoding of Code 16K symbology. Code 16K is a two-dimensional (stacked rows), ultra-high density bar code. It is based on Code 128 and is used widely to label unit-dose packaging for the health care industry.
Default:
Standard
Syntax:
CPdata Acceptable values for data are: 0 1 2
Disabled Standard Code 16K enabled Code 16K enabled with Function Code 1
When you enable Code 16K with Function Code 1, the reader decodes the bar code label and checks for a Function Code 1 in the first data character position. If a Function Code 1 is the first character, the reader substitutes this Code 16K symbology identifier string for the Function Code 1 character. Scan:
One of these bar codes: Disable Code 16K
*$+CP0* *$+CP0*
Standard Code 16K Enabled
*$+CP1* *$+CP1*
Code 16K Enabled With Function Code 1
*$+CP2* *$+CP2*
12-18
Page 366
NF
BC Configuration Command Reference
12
Code 2 of 5 Purpose:
Enables or disables decoding of Code 2 of 5 symbology. Code 2 of 5 uses the bars to encode information and the spaces to separate the individual bars. This code is discrete and self-checking. You can only enable Code 2 of 5 if the Interleaved 2 of 5 (I 2 of 5) code is disabled. If you enable I 2 of 5, Code 2 of 5 is automatically disabled.
Default:
Disabled
Syntax:
CCdata where data consists of three digits as follows:
Scan:
First digit:
0 1
Code 2 of 5, 3 Bar Start/Stop Code 2 of 5, 2 Bar Start/Stop
Second and third digits:
00 01-32
Disable Code 2 of 5 Label Length
To disable Code 2 of 5, scan this bar code: Disable Code 2 of 5
*$+CC000* *$+CC000*
Or:
To enable Code 2 of 5: 1. Scan one of these bar codes: Code 2 of 5, 3 Bar Start/Stop
*+/$+CC0* *+/$+CC0*
Code 2 of 5, 2 Bar Start/Stop
*+/$+CC1* *+/$+CC1*
12-19
Page 367
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
Code 2 of 5 (continued) 2. Scan a two-digit numeric value to set the label length (01-32) from these bar codes.
*0* *0*
*2*
*1*
*3*
*2*
*3*
*4*
*5*
*6*
*7*
*8*
*9*
*4*
*6*
*8*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-20
*1*
*5*
*7*
*9*
Page 368
NF
BC Configuration Command Reference
12
Code 39 Purpose:
Enables or disables decoding of Code 39 symbology. Code 39 is discrete, variable length, and self-checking. The character set is uppercase A to Z, 0 to 9, dollar sign ($), period (.), slash (/), percent (%), space ( ), plus (+), and minus (-). There are three types of ASCII the reader decodes: •
Code 39 non-full ASCII
•
Code 39 full ASCII
•
Code 39 mixed-full ASCII
Code 39 non-full ASCII Non-full ASCII uses a one-character encoding scheme. For example, you encode the data “SAMPLE” as follows:
*SAMPLE* *SAMPLE*
This label decodes as SAMPLE. Code 39 full ASCII Full ASCII uses a two-character encoding scheme to extend the character set to 128 characters. You use the dollar sign ($), slash (/), percent (%), or plus (+) followed by an uppercase letter to represent one of the characters in the extended set. You must encode lowercase letters as a plus sign (+) followed by their uppercase equivalents. For a list of ASCII characters and their Code 39 representations, see the “Full ASCII Table” in Appendix C. Use Code 39 full ASCII to enter ASCII control characters or lowercase characters as data. You should also enable Code 39 full ASCII to use ASCII command characters. For example, you encode the data “sample” in Code 39 full ASCII as follows:
*+S+A+M+P+L+E* *+S+A+M+P+L+E*
In Code 39 non-full ASCII, this label decodes as +S+A+M+P+L+E. In Code 39 full ASCII, this label decodes as sample. Code 39 mixed-full ASCII Use mixed-full ASCII when printers encode the same label two different ways. For example, if you have a bar code with the data $%a, some printers encode the data as follows:
*/D/E+A* */D/E+A*
12-21
Page 369
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
Code 39 (continued) In the Full ASCII Table in Appendix C, /D represents $ and /E represents %. If you configure the reader for Code 39 full ASCII, the reader decodes the data as $%a because there are three valid full ASCII character pairs to represent the data. Other printers encode the data $%a as:
*$%+A* *$%+A*
The $ and % are valid Code 39 characters in the non-full ASCII character set. However, the reader will not decode this label if it is configured for full ASCII, because the data is not represented by valid full ASCII character pairs. To decode the label correctly, you need to configure the reader for mixed-full ASCII. When you configure the reader for Code 39 mixed-full ASCII, the reader will decode both of the labels above as $%a. Mixed-full ASCII interprets any valid full ASCII character pairs that appear in the label, but does not require that all data be encoded with a valid full ASCII character pair. If you are uncertain how your labels are encoded, configure the reader for mixed-full ASCII, which decodes all valid Code 39 labels. If you configure the reader for Code 39 full ASCII, you should check for Code 39 mixed-full ASCII. Mixed-full ASCII does not apply when you configure the reader for non-full ASCII. Note: The interpretive text shown under bar code labels does not always accurately reflect the data that is encoded in the label. The interpretive text represents how the label should be decoded. Use this table to help configure your reader.
Default:
12-22
Code 39 Option
Bar Code Label
Decodes
Non-full ASCII
$%+A /D/E+A
$%+A /D/E+A
Full ASCII
$%+A /D/E+A
No decode $%a
Mixed-full ASCII
$%+A /D/E+A
$%a $%a
Enable Code 39 Full ASCII with no check digit (111)
Page 370
NF
BC Configuration Command Reference
12
Code 39 (continued) Syntax:
CBdata Acceptable values for data must be three digits, corresponding to: First digit:
0 1 2 3 4
Disabled Enabled with no check digit Enabled with check digit HIBC (Health Industry Bar Code) With AIAG check digit
Second digit:
0 1
Discard check digit Transmit check digit
Third digit:
0 1 2
Code 39 non-full ASCII Code 39 full ASCII Code 39 mixed-full ASCII
Note: Selecting HIBC Code 39 automatically sets the configuration to non-full ASCII with the check digit transmitted. Scan:
To disable Code 39: Disable Code 39
*$+CB0* *$+CB0*
Or:
To enable Code 39: 1. Scan this bar code: Enter Accumulate Mode / Enable Code 39
*+/$+CB* *+/$+CB*
2. Scan one of these bar codes to set the first digit: Without a Check Digit
With a Check Digit
*1*
*2*
HIBC Code 39
With AIAG Check Digit
*3*
*4*
*1*
*3*
*2*
*4*
12-23