The text of a manual · part 49 of 57

JANUS 2020 Hand-Held Computer User's Manual, pages 481 to 490

Pages 481 to 490 of 570

The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec J2020 and Intermec JR2020

Page 481

Reader Keypad Charts

B

Large Numeric Keypad (continued)

fffC fffD fffE

To Enter

Press the Key(s)

+ { } fffF fffG

To Enter

Press the Key(s)

- (dash) / u0 u9

Note: You can use the to key combinations shown above only when the number pad is disabled. For help, see “Using the Number Pad” in Chapter 2. To Use the Number Pad Enable the number pad Turn Num Lock on and off Disable the number pad With Num Lock Turned On To Enter 0 to 9 space . (period) end cursor down page down cursor left cursor right home cursor up page up insert delete ffe fe ffe

Press the Key(s)

0 9 s us . u1 u2 u3 u4 u6 u7 u8 u9 u0 u.

Press the Key(s)

With Num Lock Turned Off To Enter to end or cursor down page down cursor left cursor right home cursor up page up insert delete space 0 to 9 . (period)

1 2 3 4 6 7 8 9 0 . s us u0 u9 u.

Press the Key(s)

or to

B-11

Page 482

JANUS 2020 Hand-Held Computer User’s Manual

Large Numeric Keypad (continued) To Use Control Mode 1. Enter Control mode 2. Adjust the display 3. Exit Control mode To Adjust the Display Make the display contrast darker Make the display contrast lighter Turn the display backlight on or off Change the scroll line to line 8 Change the scroll line to line 16 Change the scroll line to line 25 Change the characters to normal height Change the characters to double height Use automatic viewport movement Use manual viewport movement Make the beep volume quieter Make the beep volume louder fa d

Press the Key(s) - see the next table h j e 8 6 5 3 9 2 1 g i

Press the Key(s)

Note: You can use Control mode to adjust the display at the DOS prompt or when you run an application. For help, see “Adjusting the Display From the DOS Prompt” in Chapter 2.

B-12

Page 483

NF

BC

C Configuration and Full ASCII Charts

Page 484

NF

BC

Page 485

NF

BC Configuration and Full ASCII Charts

C

This appendix includes reference tables you can use when configuring communications protocols and the key code look-up table on the reader. It also contains a full ASCII chart and charts of Code 39 bar code labels that you can scan with the JANUS 2020 reader.

Entering ASCII Control Characters You may need to enter ASCII control characters to configure these parameters in IC.EXE or the Communications Manager screens: •

Preambles and postambles. You can include ASCII control characters in postambles and preambles.

•

Protocol characters, such as EOR and EOM. For some communications protocols, you must set the protocol character to an ASCII control character.

To enter ASCII control characters for preambles and postambles 1. Decide which ASCII control character you want to set for the preamble or postamble. Use the next table to find the character and the escape sequence. ASCII Control Character

Escape Sequence

\

Backslash

\\

BEL

Bell

\a

BS

Backspace

\b

CR

Carriage Return

\r

FF

Form Feed

\f

HT

Horizontal Tab

\t

LF

Line Feed

\n

Other ASCII control characters

\xhh where hh is the two-digit hexadecimal number for the ASCII control character.

If the table does not include the ASCII control character, you must use the Full ASCII Table later in this appendix to identify the two-digit hexadecimal number for the control character. 2. Use IC.EXE to configure a preamble or postamble. Move the cursor to the field for the preamble or postamble. For help using IC.EXE, see Chapter 5, “Configuring the Reader.”

C-3

Page 486

JANUS 2020 Hand-Held Computer User’s Manual NF BC

3. Type the characters you identified in Step 1. Here are two examples: •

You find Carriage Return (CR) Line Feed (LF) in the Entering ASCII Control Characters for Preambles and Postambles table. The CR is \r and the LF is \n. You type this value: \r\n

•

You find ETX in the Full ASCII Table and learn that 03 is the two-digit hex number for ETX. You type \x followed by the hex number: \x03

Note: If you type the hex number for an ASCII character above 7F hex (128 decimal), the reader displays the extended ASCII character instead of its numeric value in the dialog box. To enter ASCII control characters for protocol characters 1. Decide which ASCII control character you want to set for the protocol character. Use the next table to find the character and the key sequence. 2. Use IC.EXE or Communications Manager to configure a communications protocol. Move the cursor to the field for the protocol character. For help using IC.EXE, see Chapter 5, “Configuring the Reader.” For help using Communications Manager, see Chapter 6, “Networking the Reader.” cB b

3. Press the key sequence you identified in Step 1. For example, to enter the ASCII character STX, press . The word <STX> appears in the field. Note: To disable a protocol character, move the cursor to the space next to the protocol character and press .

C-4

Page 487

NF

BC Configuration and Full ASCII Charts

C

Entering ASCII Control Characters for Protocol Characters ASCII Control Character ACK BEL BS CAN CR DC1 DC2 DC3 DC4 DLE EM cF cG cH cX cM cQ cR cS cT cP cY

Key Sequence

ASCII Control Character ENQ EOT ESC ETB ETX FF FS GS HT LF NAK cE cD aA cW cC cL cl cm cI cJ cU

Key Sequence

ASCII Control Character NUL RS SI SO SOH STX SUB SYN US VT cp cn cO cN cA cB cZ cV co cK

Key Sequence

Note: IRL does not use these key sequences for the ASCII control characters FS, GS, RS, US, and NUL. The Interactive Configuration application (IC.EXE) and Communications Manager do use them.

C-5

Page 488

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Configuration Options for User-Defined Protocol User-Defined protocol supports 24 different configurations. The six key parameters that determine the User-Defined configuration are POL, SEL, RES, REQ, AFF, and NEG. The next table lists all the valid combinations for these six User-Defined protocol parameters. The most common User-Defined configurations have been named and are listed first in the table. User-Defined Configuration

POL

SEL

RES

REQ

AFF

NEG

User-Defined Point-to-Point protocol ACK/NAK protocol ACK/NAK protocol with timeout One-character solicitation with handshake User-Defined Polling Mode D protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol, - - X X, - - - - - - - - X X X X X X X X X X, - - - X, - - X X X X X X, - - - - X X X X X, - - - X X X X, - - X X X, - X X X, - - X X, - X X X, - X, - X, - X, - - - X, - X, - - X X X X, X X, X X, X X, X, X X, X X, X, X X X X, X X, X X, X X, X, X X, X X, X

X, C-6

Means the parameter is set to a character. Means the parameter is disabled.

Page 489

NF

C

BC Configuration and Full ASCII Charts

POL and SEL Combinations for Multi-Drop Protocol To configure User-Defined Multi-Drop protocol, you use POL and SEL character combinations. You must assign the POL and SEL protocol characters in a predetermined combination. The following table lists the device address and the corresponding POL and SEL combinations. When you configure Multi-Drop protocol, you select the device address and then the reader automatically sets the predefined POL and SEL combination listed for that address. Device Address

POL

SEL

A

FS

GS

B

RS

C

Device Address

POL

SEL

Q

<

=

US

R

>

?

SP

!

S

@

A

D

"

#

T

B

C

E

$

%

U

D

E

F

&

‘

V

F

G

G

(

)

W

H

I

H

*

+

X

J

K

I

‘

-

Y

L

M

J

.

/

Z

N

O

K

0

1

0

P

Q

L

2

3

1

R

S

M

4

5

2

T

U

N

6

7

3

V

W

O

8

9

4

X

Y

P

:

;

5

Z

[

C-7

Page 490

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Key Codes Use the key codes to redefine scanned characters to a keystroke equivalent. Find each key’s four-digit hexadecimal value in the Key Code table. You can use the key code in an application or to change the reader’s key code look-up table. For help, see the “Key Code Look-Up Table” in Chapter 12. Key

Lists each key on a standard 102 key PC keyboard.

Normal Shift

Lists the key code value for the Shift key plus the key.

Control Alt

Lists the key code value for each key.

Lists the key code for the Control key plus the key.

Lists the key code for the Alt key plus the key.

aA

For example, the key code for code for is 1E00.

uA

(an uppercase letter A) is 1E41. The key

Key Code Table Key

Normal

Shift

Control

Alt

F1

3B00

5400

5E00

6800

F6

4000

5900

6300

6D00

F11

8500

8700

8900

8B00

F2

3C00

5500

5F00

6900

F7

4100

5A00

6400

6E00

F12

8600

8800

8A00

8C00

F3

3D00

5600

6000

6A00

F8

4200

5B00

6500

6F00, - - - F4

3E00

5700

6100

6B00

F9

4300

5C00

6600

7000

Scroll Lock

C-8