Page 411

NF

BC Configuration Command Reference

12

IRL End Program Block Purpose:

Indicates the last block of an IRL program when you download a program to the reader. Note: You must select the communications port and protocol before you set the parameters to define that protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.

Default:

SO (shift out)

Syntax:

XDdata where data can be any ASCII character.

Scan:

To disable IRL End Program Block, scan this bar code: Disable IRL End Program Block

*$+XD* *$+XD*

Or:

To set IRL End Program Block to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / IRL End Program Block

*+/$+XD* *+/$+XD*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-61

Page 412

JANUS 2020 Hand-Held Computer User’s Manual NF BC

IRL EOP (End of Program) Purpose:

An EOP indicates the end of an IRL program block when you download a program to the reader. Note: You must select the communications port and protocol before you set the parameters to define that protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.

Default:

SYN (synchronous idle)

Syntax:

XBdata where data can be any ASCII character.

Scan:

To disable EOP, scan this bar code: Disable EOP

*$+XB* *$+XB*

Or:

To set EOP to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set EOP

*+/$+XB* *+/$+XB*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-62

Page 413

NF

BC Configuration Command Reference

12

IRL PAK (Program Acknowledge) Purpose:

The reader sends this character to the host computer to acknowledge an IRL program that it has received. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.

Default:

RS (record separator)

Syntax:

ZAdata where data can be any ASCII character.

Scan:

To disable PAK, scan this bar code: Disable PAK

*$+ZA* *$+ZA*

Or:

To set the PAK to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set PAK

*+/$+ZA* *+/$+ZA*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-63

Page 414

JANUS 2020 Hand-Held Computer User’s Manual NF BC

IRL PSS (Program Statement Separator) Purpose:

Separates individual IRL program statements from each other. Note: Do not define PSS as the same character used for EOM. You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.

Default:

CR (carriage return)

Syntax:

XEdata where data can be any ASCII character.

Scan:

To disable PSS, scan this bar code: Disable PSS

*$+XE* *$+XE*

Or:

To set the PSS to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set PSS

*+/$+XE* *+/$+XE*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-64

Page 415

NF

BC Configuration Command Reference

12

IRL Run Purpose:

Designates the end of an IRL program download and causes the reader to execute the program. The Run command takes the place of the last EOP character in the downloaded program. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.

Default:

DC2

Syntax:

XCdata where data can be any ASCII character.

Scan:

To disable IRL Run, scan this bar code: Disable IRL Run

*$+XC* *$+XC*

Or:

To set IRL Run to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set IRL Run

*+/$+XC* *+/$+XC*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-65

Page 416

JANUS 2020 Hand-Held Computer User’s Manual NF BC

IRL SOP (Start of Program) Purpose:

Defines the beginning of an IRL program download from the host computer. Note: You must select the communications port and protocol before you set the parameters that define the protocol. For help, see “Communications Protocol, Configure” earlier in this chapter.

Default:

SI (shift in)

Syntax:

XAdata where data can be any ASCII character.

Scan:

To disable SOP, scan this bar code: Disable SOP

*$+XA* *$+XA*

Or:

To set SOP to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set SOP

*+/$+XA* *+/$+XA*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-66

Page 417

NF

BC Configuration Command Reference

12

Key Code Look-Up Table Purpose:

You can remap up to 20 scanned characters to a keystroke equivalent.

Default:

102-key PC keyboard (no modifications)

Syntax:

WMdata where data can be any ASCII character.

Scan:

To reset the look-up table to the default setting, scan this bar code: Clear Key Code Look-Up Table

*$+WN* *$+WN*

Or:

To modify any scanned character, complete these steps: 1. Scan this bar code: Modify Key Code Look-Up Table

*+/$+WM* *+/$+WM*

2. Scan a bar code for data for the key you want to redefine. Use the “Full ASCII Bar Code Chart” in Appendix C. Note: Enclose the redefined character and ASCII value in quotes to prevent the reader from interpreting the option as a reader or configuration command (see the example). 3. Find the four-digit hexadecimal value for the key you want to assign. For help, see “Key Codes” in Appendix C. 4. Scan a bar code for each digit using the “Full ASCII Bar Code Chart” in Appendix C. 5. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-67

Page 418

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Key Code Look Up Table (continued) Example:

You want to redefine the uppercase letter A to the [ (left square bracket). In the Full ASCII Table, the hex value for [ is 5B. To redefine A, enter this command: $+WM"A1A5B"

You can also change the Key Code Look-Up Table in IC.EXE. To redefine A to [ in IC.EXE 1. From the Op menu in IC.EXE, select Key Codes.

uA j e

2. Select Redefine. 3. Press 4. Press

.

to move to the next field.

5. To enter the hexadecimal value for [, press 6. Press

1A5B

.

.

7. Exit IC.EXE and save your changes.

Keypad Caps Lock Purpose:

Turns the caps lock on and off. With the caps lock turned on, all alphabetic characters you type on the keypad will be uppercase or capital letters. By default, the reader turns the caps lock off when you boot the reader.

Default:

Caps lock off

Syntax:

KAdata Acceptable values for data are: 0 1

Scan:

Caps lock off Caps lock on

One of these bar codes: Caps Lock Off

*$+KA0* *$+KA0*

Caps Lock On

*$+KA1* *$+KA1*

12-68

Page 419

NF

BC Configuration Command Reference

12

Keypad Clicker Purpose:

Enables or disables the keypad clicks. The reader sounds a click each time you press a key or decode a two-dimensional symbology.

Default:

Enabled

Syntax:

KCdata Acceptable values for data are: 0 1

Scan:

Disable keypad clicker Enable keypad clicker

One of these bar codes: Disable Keypad Clicker

*$+KC0* *$+KC0*

Enable Keypad Clicker

*$+KC1* *$+KC1*

12-69

Page 420

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Keypad Ctrl Key Functions Purpose:

Defines the functionality of the Control (

Default:

All Ctrl key functions enabled

Syntax:

KBdata c

) key.

Acceptable values for data are: 0 1 2 Scan:

Enable Ctrl key Prohibit Ctrl-Alt-Del sequence (warm reboot) Prohibit Ctrl key combinations

One of these bar codes: Enable Ctrl Key

*$+KB0* *$+KB0*

Prohibit Ctrl-Alt-Del

*$+KB1* *$+KB1*

Prohibit Ctrl Key Combinations

*$+KB2* *$+KB2*