The text of a manual · part 38 of 57
JANUS 2020 Hand-Held Computer User's Manual, pages 371 to 380
Pages 371 to 380 of 570
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec J2020 and Intermec JR2020
Page 371
NF
BC Configuration Command Reference
12
Code 39 Purpose:
Enables or disables decoding of Code 39 symbology. Code 39 is discrete, variable length, and self-checking. The character set is uppercase A to Z, 0 to 9, dollar sign ($), period (.), slash (/), percent (%), space ( ), plus (+), and minus (-). There are three types of ASCII the reader decodes: •
Code 39 non-full ASCII
•
Code 39 full ASCII
•
Code 39 mixed-full ASCII
Code 39 non-full ASCII Non-full ASCII uses a one-character encoding scheme. For example, you encode the data “SAMPLE” as follows:
*SAMPLE* *SAMPLE*
This label decodes as SAMPLE. Code 39 full ASCII Full ASCII uses a two-character encoding scheme to extend the character set to 128 characters. You use the dollar sign ($), slash (/), percent (%), or plus (+) followed by an uppercase letter to represent one of the characters in the extended set. You must encode lowercase letters as a plus sign (+) followed by their uppercase equivalents. For a list of ASCII characters and their Code 39 representations, see the “Full ASCII Table” in Appendix C. Use Code 39 full ASCII to enter ASCII control characters or lowercase characters as data. You should also enable Code 39 full ASCII to use ASCII command characters. For example, you encode the data “sample” in Code 39 full ASCII as follows:
*+S+A+M+P+L+E* *+S+A+M+P+L+E*
In Code 39 non-full ASCII, this label decodes as +S+A+M+P+L+E. In Code 39 full ASCII, this label decodes as sample. Code 39 mixed-full ASCII Use mixed-full ASCII when printers encode the same label two different ways. For example, if you have a bar code with the data $%a, some printers encode the data as follows:
*/D/E+A* */D/E+A*
12-21
Page 372
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Code 39 (continued) In the Full ASCII Table in Appendix C, /D represents $ and /E represents %. If you configure the reader for Code 39 full ASCII, the reader decodes the data as $%a because there are three valid full ASCII character pairs to represent the data. Other printers encode the data $%a as:
*$%+A* *$%+A*
The $ and % are valid Code 39 characters in the non-full ASCII character set. However, the reader will not decode this label if it is configured for full ASCII, because the data is not represented by valid full ASCII character pairs. To decode the label correctly, you need to configure the reader for mixed-full ASCII. When you configure the reader for Code 39 mixed-full ASCII, the reader will decode both of the labels above as $%a. Mixed-full ASCII interprets any valid full ASCII character pairs that appear in the label, but does not require that all data be encoded with a valid full ASCII character pair. If you are uncertain how your labels are encoded, configure the reader for mixed-full ASCII, which decodes all valid Code 39 labels. If you configure the reader for Code 39 full ASCII, you should check for Code 39 mixed-full ASCII. Mixed-full ASCII does not apply when you configure the reader for non-full ASCII. Note: The interpretive text shown under bar code labels does not always accurately reflect the data that is encoded in the label. The interpretive text represents how the label should be decoded. Use this table to help configure your reader.
Default:
12-22
Code 39 Option
Bar Code Label
Decodes
Non-full ASCII
$%+A /D/E+A
$%+A /D/E+A
Full ASCII
$%+A /D/E+A
No decode $%a
Mixed-full ASCII
$%+A /D/E+A
$%a $%a
Enable Code 39 Full ASCII with no check digit (111)
Page 373
NF
Syntax:
BC Configuration Command Reference
12
CBdata Acceptable values for data must be three digits, corresponding to: First digit:
0 1 2 3 4
Disabled Enabled with no check digit Enabled with check digit HIBC (Health Industry Bar Code) With AIAG check digit
Second digit:
0 1
Discard check digit Transmit check digit
Third digit:
0 1 2
Code 39 non-full ASCII Code 39 full ASCII Code 39 mixed-full ASCII
Note: Selecting HIBC Code 39 automatically sets the configuration to non-full ASCII with the check digit transmitted. Scan:
To disable Code 39: Disable Code 39
*$+CB0* *$+CB0*
Or:
To enable Code 39: 1. Scan this bar code: Enter Accumulate Mode / Enable Code 39
*+/$+CB* *+/$+CB*
2. Scan one of these bar codes to set the first digit: Without a Check Digit
*1*
With a Check Digit
*2*
*1*
*2*
HIBC Code 39
With AIAG Check Digit
*3*
*4*
*3*
*4*
12-23
Page 374
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Code 39 (continued) 3. Scan one of these bar codes to set the second digit: Discard Check Digit
Transmit Check Digit
*0*
*1*
*0*
*1*
4. Scan one of these bar codes to set the third digit: Code 39 Non-Full ASCII
Code 39 Full ASCII
*0*
*1*
*0*
Code 39 Mixed-Full ASCII
*2* *2*
5. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-24
*1*
Page 375
NF
BC Configuration Command Reference
12
Code 49 Purpose:
Enables or disables decoding of Code 49 symbology. Code 49 is a multirow symbology for high data density. The last character in each row is used for row checking and the last two characters of the symbol are used for overall checking. Function codes designate where to place the predefined data string in a Code 49 label. Whenever a reader encounters a function code, it replaces the function code with the defined string before transmitting the data to the workstation. A single Code 49 symbol may contain several different variable length data fields. Function Code 1 (F1) identifies a data system. Function Code 2 (F2) indicates the end of a data field.
Default:
Code 49 Enabled, Function Code 1 disabled, Function Code 2 set to CR LF, and Function Code 3 disabled.
Syntax:
CJdata CKdata CLdata CMdata
Code 49 Function Code 1 Function Code 2 Function Code 3
Acceptable values for data are:
Scan:
Code 49:
0 1
Function Code 1:
Any two ASCII characters.
Function Code 2:
Any four ASCII characters
Function Code 3:
Any two ASCII characters
One of these bar codes: Disable Code 49
*$+CJ0* *$+CJ0*
Scan:
Disabled Enabled
Enable Code 49
*$+CJ1*
*$+CJ1*
To disable any of the function codes, scan one of these bar codes: Disable Function Code 1
Disable Function Code 2
*$+CK*
*$+CL*
*$+CK*
*$+CL*
12-25
Page 376
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Code 49 (continued) Disable Function Code 3
*$+CM* *$+CM*
Or:
To set one of the function codes to a character string: 1. Scan one of these bar codes: Enter Accumulate Mode / Set Function Code 1
*+/$+CK* *+/$+CK*
Enter Accumulate Mode / Set Function Code 2
*+/$+CL* *+/$+CL*
Enter Accumulate Mode / Set Function Code 3
*+/$+CM* *+/$+CM*
2. Scan any character from the “Full ASCII Bar Code Chart” in Appendix C. You can define two characters each for Function Codes 1 and 3, and four characters for Function Code 2. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-26
Page 377
NF
BC Configuration Command Reference
12
Code 93 Purpose:
Enables or disables decoding of Code 93 symbology. Code 93 is a variable length, continuous symbology that uses four element widths. It complements Code 39.
Default:
Enabled
Syntax:
CFdata Acceptable values for data are: 0 1
Scan:
Disabled Enabled
One of these bar codes: Disable Code 93
*$+CF0* *$+CF0*
Enable Code 93
*$+CF1* *$+CF1*
12-27
Page 378
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Code 128 Purpose:
Enables or disables decoding of Code 128 symbology. Code 128 is a very high density alphanumeric symbology that supports the extended ASCII character set. It is a variable length, continuous code that uses multiple element widths.
Default:
Standard
Syntax:
CHdata Acceptable values for data are: 0 1 2
Scan:
Disabled Standard Code 128 UCC/EAN Code 128
One of these bar codes: Disable Code 128
*$+CH0* *$+CH0*
Enable Standard Code 128
*$+CH1* *$+CH1*
Enable UCC/EAN Code 128
*$+CH2* *$+CH2*
Notes:
If you configure Standard Code 128, the reader will not decode Function Code 1 characters in the first position of a bar code label. Any subsequent Function Code 1 characters are translated to the ASCII GS character as a separator for variable length fields. If you configure UCC/EAN Code 128, the reader will decode a bar code label as Standard Code 128 unless one of the first two characters are a start character and a Function Code 1. In this case, the bar code label is processed as described next: 1. The Function Code 1 character is not transmitted. 2. The three symbology ID characters, ]C1, are transmitted. 3. The remaining Code 128 characters are decoded as Standard Code 128.
12-28
Page 379
NF
BC Configuration Command Reference
12
Command Processing Purpose:
Command processing allows you to disable or enable reader commands. For example, you can disable the Backlight command. There are two ways to enable or disable reader commands: •
Use the Command Processing configuration command described here.
•
Use the Reader Commands option on the Op menu in the Interactive Configuration application (IC.EXE) program.
If you want to disable or enable several commands, it is easier to use IC.EXE. For help, see Chapter 5, “Configuring the Reader.” Default:
All reader commands enabled
Syntax:
DCdata Acceptable values for data are: 0 1 2 3 command0 command1
Disable all reader commands Enable all reader commands Disable override Enable override Disable reader command Enable reader command
The override option is a temporary setting that allows you to enable all the reader commands for as long as you need them. When you want to return to the previous setting, you disable the override. Note: If you disable all the reader commands ($+DC0), you cannot change the reader’s configuration or exit from an IRL program. To enable the reader commands again, use IC.EXE, or edit the configuration “*.ini” file. Scan:
To enable all the reader commands or override the current settings, scan one of these bar codes: Disable All Reader Commands
*$+DC0*
Enable All Reader Commands
*$+DC1*
*$+DC0*
*$+DC1*
Disable Override
Enable Override
*$+DC2* *$+DC2*
*$+DC3*
*$+DC3*
12-29
Page 380
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Command Processing (continued) Or:
To disable or enable specific reader commands, perform these steps: 1. Scan this bar code: Enter Accumulate Mode / Command Processing
*+/$+DC* *+/$+DC*
2. Scan the bar code to disable or enable one reader command. Note: If there are two bar codes for a reader command, you must scan them in order, left to right. Backspace
*-*
*+*
*-*
*+*
Backlight
Change Configuration
*%.*
*$+*
*%.*
*$+*
Clear
(continued)
*-*
*-*
*-*
*-*
Enter Accumulate Mode
(continued)
*+*
*/*
*+*
*/*
Exit Accumulate Mode
(continued)
*-*
*/*
*-*
*/*
IRL File, Clear
IRL File, Receive
*.$*
*.%*
*.$*
12-30
(continued)
*.%*