Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 36 of 57

JANUS 2020 Hand-Held Computer User's Manual, pages 351 to 360

Pages 351 to 360 of 570

The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec J2020 and Intermec JR2020

Page 351

NF

BC

12 Configuration Command Reference

Page 352

NF

BC

Page 353

NF

BC Configuration Command Reference

12

This chapter is an alphabetical list of all the configuration commands supported on the reader.

Using Configuration Commands A configuration command changes the way the reader operates. For example, you can change the Beep Volume and make the reader beep very loud in a noisy environment. You can execute configuration commands by: • scanning a command from a Code 39 or Code 93 bar code label.

• choosing a command from a menu by pressing keys on the keypad.

• sending a command from a host computer.

• executing a command in an IRL program or applications using Reader Services.

Note: You can send configuration commands from a host computer only when the application is programmed to accept the command syntax. You can find the following information about each configuration command in this chapter: •

Command description and purpose

•

Default setting

•

Command syntax and options

•

Bar code labels you can scan to set or change each command

The configuration commands are listed alphabetically by command name. For a list of bar code symbology, communications, or operations commands, use the next table, “Configuration Commands Listed by Category.” If you want to look up a command by its syntax, see the “Configuration Commands by Syntax” list in Appendix A. Note: For help about the radio frequency (RF) configuration commands, see the JANUS 900 MHz Radio Frequency Quick Reference Guide.

12-3

Page 354

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Configuration Commands Listed by Category This chapter lists the configuration commands in alphabetical order. Use this next list to find the configuration commands you may need to set for bar code symbologies, communications, and operations. Bar Code Symbologies

Communications (continued)

Codabar, 12-16

EOF (End of File), 12-52

Code 11, 12-17

EOM (End of Message), 12-53

Code 16K, 12-18

EOR (End of Record), 12-55

Code 2 of 5, 12-19

Flow Control, 12-56

Code 39, 12-21

Intercharacter Delay, 12-57

Code 49, 12-25

IRL BAK (Bad Program Acknowledge), 12-60

Code 93, 12-27

IRL End Program Block, 12-61

Code 128, 12-28

IRL EOP (End of Program), 12-62

Interleaved 2 of 5, 12-58

IRL PAK (Program Acknowledge), 12-63

MSI, 12-72

IRL PSS (Program Statement Separator), 12-64

Plessey, 12-76

IRL Run, 12-65

UPC/EAN, 12-97

IRL SOP (Start of Program), 12-66 LRC (Longitudinal Redundancy Check), 12-72

Communications

NEG (Negative Acknowledge), 12-74

Address, Multi-Drop, 12-7

Parity, 12-75

AFF (Affirmative Acknowledge), 12-8

POL (Polling), 12-77

Baud Rate, 12-10

Records Per Block, 12-80

Communications Dock Port, 12-35

REQ (Request for Acknowledge), 12-82

Communications Port, Select COM Port, 12-36

RES (Reset), 12-83

Communications Port, UART Restore, 12-37

SEL (Select), 12-89

Communications Protocol, Configure, 12-38

SOM (Start of Message), 12-90

Communications Protocol, Activate, 12-41

Stop Bits, 12-91

Communications Protocol, Multi-Drop, User-Defined, 12-42

Timeout Delay, 12-92

Data Bits, 12-43

Turnaround Delay, 12-96

12-4

Transmit Abort Timeout, 12-94

Page 355

NF

BC Configuration Command Reference

12

Configuration Commands Listed by Category (continued) Operations Automatic Shutoff, 12-9 Beep Duration, 12-12 Beep Frequency, 12-13 Beep Volume, 12-15 Command Processing, 12-29 Decode Security, 12-44 Display Backlight Timeout, 12-44 Display Contrast, 12-46 Display Mode, IRL, 12-47 Display Setup, 12-48 Key Code Look-Up Table, 12-67 Keypad Caps Lock, 12-68 Keypad Clicker, 12-69 Keypad Ctrl Key Functions, 12-70 Keypad, Numeric, 12-71 Postamble, 12-78 Preamble, 12-79 Scan Ahead, 12-84 Scanner Mode, 12-85 Scanner Redundancy, 12-86 Scanner Timeout, 12-87 Scanner Trigger, 12-88 Viewport Movement Keys, 12-100 Viewport Movement Mode, 12-100 Viewport Movement Steps, 12-101

12-5

Page 356

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Entering Variable Data in a Configuration Command You can enter variable data for many of the configuration commands. For example, you can set the End of File (EOF) character to any ASCII character. You need to follow these general instructions to enter variable data. To enter variable data in a configuration command 1. Scan a bar code label with this syntax: +/$+command where: +/ is the syntax for the Enter Accumulate Mode command.

$+ is the syntax for the Change Configuration command.

command is the syntax for the command you want to change.

For example, the command syntax for EOF is FAdata. To change the EOF configuration, scan this bar code: Enter Accumulate Mode / Change Configuration / Set EOF

*+/$+FA*

*+/$+FA*

2. Scan a bar code label from the “Full ASCII Bar Code Chart” in Appendix C. To set EOF to SOH (Start of Heading), scan this label: SOH

*$A* *<SOH>*

3. Scan the Exit Accumulate Mode bar code label to update the reader’s configuration: Exit Accumulate Mode

*-/* *-/*

12-6

Page 357

NF

BC Configuration Command Reference

12

Address, Multi-Drop Purpose:

Defines the address of the communications port when you are using the Multi-Drop communications protocol. Each multi-drop address has unique POL and SEL characters that are automatically set when you configure the address. For help, see “POL and SEL Combinations for Multi-Drop Protocol” in Appendix C. Note: You must select the communications port and protocol before you can set the parameters to define that protocol. For help, see ”Communications Protocol, Configure” later in this chapter.

Default:

A

Syntax:

HCdata where data can be A through Z or 0 through 5.

Scan:

1. Scan this bar code: Enter Accumulate Mode / Change Address

*+/$+HC* *+/$+HC*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-7

Page 358

JANUS 2020 Hand-Held Computer User’s Manual NF BC

AFF (Affirmative Acknowledge) Purpose:

Enables or disables the handshake event that is an affirmative acknowledge to a message. You must enable both AFF and NEG to have a valid configuration. Note: You must select the communications port and protocol before you set the parameters to define that protocol. For help, see “Communications Protocol, Configure” later in this chapter.

Default:

Disabled

Syntax:

PGdata where data can be any ASCII character.

Scan:

To disable AFF, scan this bar code: Disable AFF

*$+PG* *$+PG*

Or:

To set AFF to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set AFF

*+/$+PG* *+/$+PG*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-8

Page 359

NF

BC Configuration Command Reference

12

Automatic Shutoff Purpose:

Defines the maximum length of time the reader remains on when there is no activity. When you do not use the reader for the length of time set for this command, the reader automatically shuts off and goes into Suspend mode. The reader also goes into a suspend state when you press to turn the reader off. When you press to turn the reader on again, the reader resumes exactly where it left off and all reader memory is saved.

q q

Power Management Tip: You should use the Automatic Shutoff feature to preserve the NiCad battery pack’s power. Note: If the reader is in a communications dock or a power supply is connected to the reader through an optical link adapter, automatic shutoff is disabled. Default:

1 minute

Syntax:

EZdata Acceptable values for data are: 0M 1M-60M 15S

Scan:

Disabled (always on) Shutoff time in minutes 15 seconds

To set the timeout to 15 seconds, scan this bar code: Set Automatic Shutoff to 15 Seconds

*$+EZ15S* *$+EZ15S*

Or:

To set the timeout in minutes: 1. Scan this bar code: Enter Accumulate Mode / Set Automatic Shutoff

*+/$+EZ* *+/$+EZ*

2. Scan a numeric value for data from these bar codes:

*0* *0*

*1* *1*

12-9

Page 360

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Automatic Shutoff (continued)

*2*

*3*

*2*

*3*

*4*

*5*

*4*

*6*

*5*

*7*

*6*

*7*

*8*

*9*

*8*

*9*

3. Scan this bar code: Timeout in Minutes

*M* *M*

4. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Baud Rate Purpose:

Sets the baud rate for the selected communications port on the reader. The baud rate must match the baud rate of the device (for example, the host computer) that the reader is communicating with. For Polling Mode D protocol, you must set the baud rate to 1200 or higher. For Multi-Drop protocol, you must set the baud rate to 2400 or higher. Note: You must select the communications port and protocol before you set the parameters to define that protocol. For help, see “Communications Protocol, Configure” later in this chapter.

Default:

12-10

9600 baud