Page 211

NF

BC Networking the Reader

6

Running Interlnk to Transfer Files With Interlnk, you can easily transfer files between your reader and a host computer or another reader. You can also make all the drives on one computer appear as if they are physically located on the other, so that you have unrestricted access to the contents of all the drives. You can run programs over the Interlnk connections. Note: You cannot execute IRL programs over an Interlnk connection. Also, you cannot run Interlnk in an RF network.

Differentiating Between Client and Server The Interlnk utility consists of two programs: Interlnk and Intersvr. These two programs are designed to be run on separate computers: •

The computer running Interlnk is called the client.

•

The computer running Intersvr is called the server.

The difference between client and server is a simple one: the client is the device from which you enter all commands. In this example, the host computer is the client:

Client

Server

2020U.187

6-25

Page 212

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Client The client is the computer from which you will access drives, directories, files, and programs that are stored on the server. You will type commands on the client’s keyboard or keypad to access those drives. Server The server is the computer that contains the drives, directories, files, and programs you want to access. The server’s drives and printers look as if they are on the client. Intersvr displays the status of the connection between Interlnk and Intersvr on the server’s screen. Sometimes your reader will be the client, and sometimes it will be the server, depending upon the task you are trying to accomplish. Intermec suggests that you always make the host computer the client because Interlnk requires more conventional memory than Intersvr and your host computer probably has more conventional memory available than your JANUS reader. Your reader should be the client when: • you want the drives on the host computer to show up on the reader as if they were physically part of the reader.

• there is an application on the host computer that you want to run on the reader.

Your reader should be the server when: • you want the drives on the reader to show up on the host computer as if they were physically part of the host computer.

• there is an application on the reader that you want to run on the host computer.

Note: The client cannot access a server’s drive that was redirected before Interlnk was started, such as a network drive.

6-26

Page 213

NF

BC Networking the Reader

6

Example of Using Interlnk Suppose the host computer has two disk drives (A and B) and two hard drives (C and D). The JANUS 2020 has four drives: three simulated drives (C, D, and E) and one Type II PC card drive (G). You want access to the drives on the reader while working at the host. Therefore, the host computer must be the client and the reader must be the server. Run Interlnk on the host computer and run Intersvr on the reader. Instructions for these tasks are included later in this chapter. Client Host computer running Interlnk e riv D A B C D Server Reader running Intersvr e riv D C D e riv D G E

H I G

Drives redirected from the reader

K 2020U.005

Note: Interlnk reserves drives E and F for the server’s drives A and B, even though the reader does not have drives A and B. Interlnk also reserves drive J for the server’s drive F, which is a placeholder on the JANUS 2020 reader.

6-27

Page 214

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Now the reader’s drives appear on the host computer, as if they were physically located on the host computer. The host computer has its original drives A, B, C, and D, plus drives G, H, I, and K. Drive I on the host computer is really the physical RAM drive E on the reader. Anything you do to the host computer’s drive I affects the reader’s drive E. You can type standard DOS commands on the host computer’s keyboard to access the directories and files in the reader’s drives. For example, to display a list of files located in the root directory of the reader’s drive E, type this command on the host computer: dir i:\

To copy a file from a directory on the host computer’s drive C to the reader’s drive E, type this command on the host computer: copy c:\shared\data\accounts.txt i:\accounts.txt

Interlnk System Requirements Your host computer and reader must meet these requirements to run Interlnk and Intersvr:

6-28

•

A serial port is available on the host computer and reader.

•

The host computer is running DOS 3.0 or higher.

•

The client has 16K of free memory.

•

The server has 130K of free memory.

•

The reader is connected to the host computer through a communications dock or optical link adapter. If you use the communications dock, you must connect the dock to the host computer with a 3-wire (2, 3, and 7) cable for Interlnk to operate properly.

Page 215

NF

BC Networking the Reader

6

Installing Interlnk on the Host Computer You need two files to run Interlnk: INTERLNK.EXE

The device driver that you load into the client’s memory.

INTERSVR.EXE

The program that you run on the server.

You must install those files on the host computer before you can run Interlnk or Intersvr on the host. You can install the files from either the MS-DOS companion disk 2 or the reader’s drive D. To install Interlnk on the host computer from companion disk 2 1. On the host computer, make sure that the current working directory is the directory where you want to install the Interlnk files. 2. Insert companion disk 2 into a disk drive on the host computer. 3. Copy INTERLNK.EXE and INTERSVR.EXE from companion disk 2 to the host computer. To install Interlnk on the host computer from the reader’s drive D 1. Connect the reader to the host computer using a 7-wire, null-modem serial cable and either the communications dock or optical link adapter. 2. Make sure that the MODE command is available on the host computer. 3. On the host computer, make sure that the current working directory is the directory where you want to install the Interlnk files. 4. At the reader’s DOS prompt, type this command to copy the Interlnk files from the reader’s drive D to the host computer: intersvr /rcopy

Or scan this bar code:

*INTERSVR /ORCOPY* *INTERSVR /RCOPY*

Follow any instructions displayed on the reader. If the host computer locks up after you copy the files, reboot the host.

6-29

Page 216

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Making the Host Computer the Client Follow these instructions to run Interlnk with the host computer as the client. When the host computer is the client, you can access all the reader’s drives by typing commands on the host computer’s keyboard. Client

Server

2020U.188

To run Interlnk with the host computer as the client 1. Connect the reader to the host computer through a communications dock or optical link adapter. If you use the communications dock, you must connect the dock to the host computer with a 3-wire (2, 3, and 7) cable for Interlnk to operate properly. 2. Edit the host computer’s AUTOEXEC.BAT and CONFIG.SYS files: •

Add a device command to CONFIG.SYS that specifies the location of INTERLNK.EXE and the number of drives to redirect from the server to the client. (If you do not include the /drives: option, Interlnk redirects three drives and you cannot access all the reader’s drives.) For example: device=c:\janus\network\interlnk.exe /drives:7

6-30

•

If you execute the Windows SMARTDRV.EXE on the host computer, remark it out of the AUTOEXEC.BAT or CONFIG.SYS file.

•

If you are not using the host computer’s COM1 and you execute the DOS command SHARE.EXE on the host computer, remark out the SHARE command in the AUTOEXEC.BAT or CONFIG.SYS file.

Page 217

NF

BC Networking the Reader

6

3. At the reader’s DOS prompt, type this command to start Intersvr: intersvr

Or scan this bar code:

*INTERSVR* *INTERSVR*

The Interlnk Server Status screen appears, but no information is displayed because the connection has not been made yet. 4. On the host computer, press Ctrl-Alt-Del to reboot and load Interlnk from the CONFIG.SYS file. Note: After you modify CONFIG.SYS and reboot your host computer once, you no longer need to reboot to establish a connection. Instead, you can type interlnk at the host computer’s DOS prompt. 5. On the reader, the Interlnk Server Status screen is updated with information about the redirected drives. Use the viewport to view the screen. For help, see “Interpreting the Server’s Status Screen” later in this chapter. You are ready to start using your Interlnk connection. For example, if the client’s drive E is redirected to the server’s drive C, type this command at the client’s DOS prompt: e:

Any command you type at the client’s drive E prompt will affect the server’s (reader’s) drive C.

6-31

Page 218

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Making the Reader the Client Follow these instructions to run Interlnk with the reader as the client. When the reader is the client, you can access all the host computer’s drives by typing commands on the reader’s keypad.

Server Client

2020U.189

To run Interlnk with the reader as the client 1. Connect the reader to the host computer through a communications dock or optical link adapter. If you use the communications dock, you must connect the dock to the host computer with a 3-wire (2, 3, and 7) cable for Interlnk to operate properly. 2. Start Intersvr by typing this command at the host computer’s command prompt: intersvr

If you are not using the host computer’s COM1 to connect to the reader, specify the correct COM port in the command line. For example: intersvr /com3

The Interlnk Server Status screen appears, but no information is displayed because the connection has not been made yet.

6-32

Page 219

NF

BC Networking the Reader

6 caf.

3. Press to warm boot the reader. A command in the reader’s CONFIG.SYS file automatically loads Interlnk into the reader’s memory. Caution Do not press any keys while the reader is performing a warm boot or you may lose data. Conseil N'appuyez pas sur des touches pendant que le lecteur se réamorce, sinon vous pouvez perdre des données. On the host computer, the Interlnk Server Status screen is updated with information about the redirected drives. For help, see “Interpreting the Server’s Status Screen” later in this chapter. You are ready to start using your Interlnk connection. For example, if the client’s drive H is redirected to the server’s floppy disk drive A, type this command at the client’s DOS prompt and press :

e h:

Or scan this bar code:

*H/Z* *H:*

All commands you type at the client’s drive H prompt affect the server’s drive A.

6-33

Page 220

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Interpreting the Server’s Status Screen When you start Intersvr, the server displays a status screen that contains two columns of information:

Microsoft Interlnk Server version 1.00

This Computer (Server) _____________ A: B: C: D: E: LPT3:

Transfer:

Other Computer (Client) ______________ equals equals equals equals equals equals

D: E: F: G: H: LPT1

Port = Com 1

Speed:

Alt + F4 = Exit

2020U.190

This Computer (Server) This column lists all drives and printer ports on the server. The screen also displays the size of hard disk drives on the server. Other Computer (Client) This column lists the drive designation on the client for each drive redirected from the server. While the client reads from or writes to the server, the word Transfer flashes at the bottom of the screen and an asterisk (*) appears next to the server drive being accessed. The status bar also indicates which server port is connected to the client and the baud rate.