Page 221

INT 7CH, Function 64H

3

INT 7CH, Function 64H Generate Sound Purpose:

This function generates a sound of specified pitch and duration.

Call With:

AX =

64H

CX =

00H

DX =

00H

Generate sound

ES:BX =Pointer to the IM_BEEP_PARAMS structure The definition for this structure is as follows: Byte

Description

0

Requested volume 0 = Off 1 = Quiet 2 = Normal 3 = Loud 4 = Very loud 5 = Default volume

1 to 2

Pitch (20 to 20,000 Hz)

3 to 4

Duration (1 to 65,000 ms)

5 to 6

Off time (1 to 65,000 ms)

nnnn

One of the standard status codes defined in Appendix A, “Status Codes.”

Return Value:

AX =

See Also:

JBEEP.CPP in Appendix B, “Sample Interrupt Programs.”

3-29

Page 222

INT 7DH, Function 08H

INT 7DH, Function 08H Reader Wedge Control Purpose:

This function provides Reader Wedge control.

Call With:

AH =

08H

Reader Wedge control

AL =

00H 01H

Clear abort callback address Modify reader configuration ES:BX Far pointer to a reader command string CX Length of the reader string Get input mode Get label symbology ES:BX Far pointer to a variable receiving the symbology

03H 06H

3-30

07H

Get length of received string CX 0010H Label selected 0020H Keyboard selected 0001H COM1 selected 0002H COM2, scanner selected (2010 and 2050) 0008H COM4 selected

08H

Get input status

0AH

Get input from keyboard or scanned label (see IRL command A) ES:BX Far pointer to IRL_PARAMS_S

0BH

Receive input from keyboard (see IRL command K) ES:BX Far pointer to IRL_PARAMS_S

0CH

Receive numeric input from keyboard or scanned label (see IRL command N) ES:BX Far pointer to IRL_PARAMS_S

Page 223

INT 7DH, Function 08H

Call With:

AL =

3

0DH

Receive input from any source in any format (see IRL command V) ES:BX Far pointer to IRL_PARAMS_S CL 00H Edit disable 01H Edit enable CH Beep mode: 00H Application beep 01H Wedge beep 02H No beep DL Display flag: 00H Flag disable 01H Flag enable DS:SI Far pointer to allowable input sources: 0000H No input source 0010H Label selected 0020H Keyboard selected 0001H COM1 selected 0002H COM2, scanner selected (2010 and 2050) 0008H COM4 selected 007FH All selected

0EH

Receive input from a selected communications port (see IRL command Y) ES:BX Far pointer to IRL_PARAMS_S CL 00H COM1 selected 01H COM2, scanner selected (2010 and 2050) 03H COM4 selected DL Protocol mode: 00H No change 01H Protocol on 02H Protocol off 03H New end-of-message character DS:SI Far pointer to the end-of-message character

10H

Link to a selected communications port ES:BX Far pointer to memory area used by Reader Wedge CX 0000H COM1 selected 0001H COM2, scanner selected (2010 and 2050) 0003H COM4 selected DX Number of bytes to allocate for the buffer array

3-31

Page 224

INT 7DH, Function 08H

Call With:

3-32

AL =

1BH

Receive input from selected source and place into buffer CX Allowed input source: 0010H Label selected 0020H Keyboard selected 0001H COM1 selected 0002H COM2, scanner port (scanner) selected (2010 and 2050) 0008H COM4 selected DX Timeout value ES:BX Far pointer to the returned source: 0000H No selection made 0010H Label selected 0020H Keyboard selected 0001H COM1 selected 0002H COM2, scanner port (scanner) selected (2010 and 2050) 0008H COM4 selected DS:SI Far pointer to the input string

1EH

Set serial protocol mode CL 00H COM1 01H COM2, scanner port (2010 and 2050) 03H COM4 CH Protocol mode: 00H No change 01H Protocol on 02H Protocol off 03H New end-of-message character DL End-of-message character

1FH

Set abort callback address CX Input source: 0010H Label selected 0020H Keyboard selected 0001H COM1 selected 0002H COM2, scanner selected (2010 and 2050) 0008H COM4 selected 007FH All selected ES:BX Far pointer to the callback routine

Page 225

INT 7DH, Function 08H

Call With:

Return Value:

AL =

20H

Set input mode CX 0000H Programmer mode 0001H Wedge mode 0002H Desktop mode

22H

Set standby wait mode CX Timeout value

23H

Unlink a communications port CX = 0000H COM1 0001H COM2, scanner port (2010 and 2050) 0003H COM4

3

When AL is one of the following values, the return value in register AX is one of the standard status codes defined in Appendix A, “Status Codes.” AL =

00H 01H 06H 0AH

0BH 0CH 0DH 0EH

10H 1BH 1EH 1FH

22H 23H

When AL = 03H, the return values are: AX =

00H 01H 02H

Programmer mode Wedge mode Desktop mode

When AL = 07H, the return value is: AX = The length of the string. When AL = 08H, the return values are: AX =

00H 10H 20H 01H 02H 08H 7FH

No selection made Label selected Keyboard selected COM1 selected COM2, scanner port selected (2010 and 2050) COM4 selected All selected

3-33

Page 226

INT 7DH, Function 08H

Return Value:

When AL = 20H, there is no return value.

Notes:

Because the number of parameters passed to the IRL functions exceed the registers available, you must pass a structure variable of type struct IRL_PARAMS_S as shown in the following C code: typedef struct { IM_USHORT timeout; IM_LENGTH_SPEC test_table[]; IM_UCHAR mask_string[]; IM_UCHAR *string; IM_USHORT *cmd_count; IM_DECTYPE *symbology; } IRL_PARAMS_S;

3-34

Page 227

INT 7DH, Function 0AH

3

INT 7DH, Function 0AH Get 2D Decoder Firmware Version Purpose:

This function returns all pertinent information about the revision level of the 2D Decoder and its firmware.

Call With:

AH = ES:BX =

0AH

Get 2D Decoder version Far pointer to the client’s Decoder response buffer (response buffer must be large enough to hold the response string)

Return Value:

The return value in register AX is one of the standard status codes defined in Appendix A, “Status Codes.”

Notes:

The JANUS 2D upon boot queries the decoder for the firmware revision level. This function returns the string “UNKNOWN” until the decoder replies with the decoder revision level.

See Also:

PL220VER.CPP in Appendix B, “Sample Interrupt Programs.”

3-35

Page 228

INT 7DH, Function 0CH

INT 7DH, Function 0CH Open COM2 Purpose:

This function opens COM2 for use by the 2D Decoder.

Call With:

AH =

Return Value:

The return value in register AX is one of the standard status codes defined in Appendix A, “Status Codes.”

Notes:

The JANUS 2D upon boot opens COM2 for use by the 2D Decoder. When COM2 is being shared with other RS-232C devices (i.e., SAVI Interrogator), it is necessary to close COM2 prior to the other device using the port and open it backup prior to the 2D Decoder using COM2.

See Also:

OPEN.CPP in Appendix B, “Sample Interrupt Programs.”

3-36

0CH

Open COM2

Page 229

INT 7DH, Function 0DH

3

INT 7DH, Function 0DH Close COM2 Purpose:

This function closes COM2 so other devices (i.e. SAVI Interrogator) can use COM2.

Call With:

AH =

Return Value:

The return value in register AX is one of the standard status codes defined in Appendix A, “Status Codes.”

Notes:

The JANUS 2D upon boot opens COM2 for use by the 2D Decoder. When COM2 is being shared with other RS-232C devices (i.e., SAVI Interrogator), it is necessary to close COM2 prior to the other device using the port and open it backup prior to the 2D Decoder using COM2.

See Also:

CLOSE.CPP in Appendix B, “Sample Interrupt Programs.”

0DH

Close COM2

3-37

Page 230

INT 7EH, Function 01H

INT 7EH, Function 01H Get Application Break Status Purpose:

This function determines if the application break sequence was entered on the keypad.

Call With:

AH = ES:BX =

Return Value:

Notes:

3-38

01H

Get application break status Far pointer to the client’s response buffer structure (two bytes, R0 and R1)

AH =

General status: 00H Valid service call 01H Invalid function number

R0 =

Keyboard scanner CPU (KSCPU) communication status 00H Successful 01H Timeout occurred during the execution of the transaction 02H No KSCPU response (timeout on first attempted transmit) 03H KSCPU is busy 04H Forced the transaction to abort 05H KSCPU failed to process an acknowledged command within the timeout period

R1 =

Application break status 00H Application break request has not been made FFH Application break request has been made

Applications that support the application break feature must either poll the unlock status using this service or implement a Ctrl-C handler (INT 23H) that queries using this service. In the latter case, the operator is required to enter Ctrl-C on the keypad after entering the application break sequence and resume the unit by pressing the 1/0 key.