Page 31
QuickBasic Library
2
5. Copy RCVINPUT.EXE to your JANUS reader and run the program. This sample program will prompt for input from either the keypad, the scanner, or COM1.
Handling a Linker Error Message You may get a linker error message when you link the QuickBasic program. If you receive the following error message, your program has more segments than the default (128): fatal error L1049:
too many segments
You need to increase the number of segments and link again. To set the number of segments • Enter the following command from the DOS prompt: LINK /SEG:nnn /NOE @progname.RSP where:
nnn is a number between 1 and 16,375.
2-5
Page 32
JANUS PSK for Basic Reference Manual
Building Your Own QuickBasic Program In the following procedure, progname is the name of your program file without an extension. Your source file (*.BAS), object file (*.OBJ), and executable file (*.EXE) all have the same filename. To build a program using QuickBasic 1. Change to the directory containing your program file, progname.BAS. 2. Create a response file, progname.RSP, for linking. The response file consists of the following four lines: progname.OBJ progname (a blank line) C:\INTERMEC\QUICKB\LIB\IM20_BAS.LIB
C:\QB45\BCOM45.LIB where: the first line lists the program file and its path. the second line lists only the executable filename with no extension. the third line is left blank. the fourth line lists the library files, including their path. 3. Compile the program from DOS: BC /T /O progname.BAS, progname, NUL.LST where: /T /O builds a standalone object file to use with BCOM45.LIB.
progname is your program name and the name for the object file, *.OBJ.
4. Link the program from the DOS prompt using the response file: LINK /NOE @progname.rsp where: /NOE searches the object files for public symbols that may be redefined in your program.
5. Copy your program, progname.EXE, to your JANUS reader and run the program.
2-6
Page 33
QuickBasic Library
2
Handling a Linker Error Message You may get a linker error message when you link the QuickBasic program. If you receive the following error message, your program has more segments than the default (128): fatal error L1049:
too many segments
You need to increase the number of segments and link again. To set the number of segments • Enter the following command from the DOS prompt: LINK /SEG:nnn /NOE @progname.RSP where:
nnn is a number between 1 and 16,375.
Debugging With JANUS Application Simulator The JANUS Application Simulator is a terminate-and-stay resident (TSR) program that you use to run JANUS applications on a PC. Without the Simulator, you cannot run JANUS applications on your PC. Whenever you start a program that uses PSK library functions, the program checks for a JANUS reader and for the JANUS Simulator. If you attempt to run a JANUS program on a PC without the Simulator, you get an error message. The Simulator captures the JANUS functions and interrupts to make the PC mimic a JANUS reader. For more information on the Simulator, refer to the JANUS Application Simulator User’s Manual, Part No. 062778. To debug a JANUS application with the Simulator 1. Start the Simulator from the DOS prompt by entering this command: janussim 2. Start QuickBasic. 3. Follow the debugging instructions provided with QuickBasic.
2-7
Page 34
JANUS PSK for Basic Reference Manual
Runtime Requirements For some library functions to work properly, you must install and run specific software components at program execution time. For example, if the reader is using a communications port and you want to use Intermec protocols, you must load a protocol handler. Because protocol handlers use a lot of memory, they are not automatically loaded for you. Other functions require the Reader Wedge.
Protocol Handlers You use the Intermec protocol handler (PHIMEC.EXE) when the reader is connected with other Intermec devices. PHIMEC.EXE works with UserDefined, Point-to-Point, Polling Mode D, and Multi-Drop protocols. You use the PC standard protocol handler (PHPCSTD.EXE) when the reader is connected to devices that use PC standard protocol. PHPCSTD.EXE provides low-level communication abilities and protocol services at the DOS level for non-communication software. It also provides byte-by-byte transfer. If your reader is a radio frequency (RF) unit, RFPH.EXE is automatically loaded. For more information on protocol handlers, refer to your JANUS user’s manual. To install a protocol handler on the reader • From the DOS prompt, enter the following command:
handler n where: handler is either PHIMEC or PHPCSTD. n is the number of the communications port. When your application is finished, the protocol handler TSR continues to run and can prevent other applications from running due to lack of memory. You can unload the protocol handler TSR by adding the unload command as the last line of the batch file that launches your application.
2-8
Page 35
QuickBasic Library
2
To unload a protocol handler on the reader • From the DOS prompt, enter the following command: unload handler n where: handler is the installed handler (PHIMEC or PHPCSTD). n is the number of the communications port.
Reader Wedge Some functions, such as imReceiveInput, allow the reader to receive input from multiple sources and process the input depending on the source. You must load the Reader Wedge (RWTSR.EXE) TSR to use these functions. When your application is finished, the Reader Wedge TSR continues to run and can prevent other applications from running due to lack of memory. You can unload the Reader Wedge TSR by adding the unload command as the last line of the batch file that launches your application. To load the Reader Wedge TSR on the reader • From the DOS prompt, enter the following command: RWTSR To unload the Reader Wedge TSR on the reader • From the DOS prompt, enter the following command: RWTSR -D
2-9
Page 36
JANUS PSK for Basic Reference Manual
Specific Functions With Runtime Requirements The following table lists the PSK functions that have runtime requirements.
Specific Runtime Requirements
2-10
This Function
Requires imCancelRxBuffer
Protocol Handler imCancelTxBuffer
Protocol Handler imCommand
Reader Wedge imGetInputMode
Reader Wedge imGetLabelSymbology
Reader Wedge imGetLength
Reader Wedge imInputStatus
Reader Wedge imIrlA
Reader Wedge imIrlK
Reader Wedge imIrlN
Reader Wedge imIrlV
Reader Wedge If data is from a communications port, use a Protocol Handler and imLinkComm.
imIrlY
Reader Wedge Protocol Handler Use imLinkComm.
imLinkComm
Reader Wedge Protocol Handler imReceiveBuffer
Protocol Handler Will not work if linked.
imReceiveBufferNoprot
Protocol Handler Will not work if linked.
imReceiveBufferNoWait
Protocol Handler Will not work if linked.
imReceiveByte
Protocol Handler You must install PHPCSTD. Will not work if linked.
imReceiveInput
Reader Wedge If data is from a communications port, use a Protocol Handler and imLinkComm.
Page 37
QuickBasic Library
2
Specific Runtime Requirements (continued) This Function
Requires imRxCheckStatus
Protocol Handler imSerialProtocolControl imLinkComm imSetDisplayMode
Reader Wedge imSetInputMode
Reader Wedge imStandbyWait
Reader Wedge imTransmitBuffer
Protocol Handler imTransmitBufferNoprot
Protocol Handler imTransmitBufferNoWait
Protocol Handler imTransmitByte
Protocol Handler You must install PHPCSTD.
imUnlinkComm
Reader Wedge Protocol Handler
Unsupported QuickBasic Functions Your JANUS reader does not support these QuickBasic light pen and joystick functions: ON PEN GOSUB ON STRIG GOSUB PEN PEN ON/OFF/STOP STICK STICKSTRIG STRIG ON/OFF/STOP Your JANUS reader does not support these QuickBasic file functions: LOCK
UNLOCK
2-11
Page 38
JANUS PSK for Basic Reference Manual
Certified QuickBasic Language Functions Because of the large number of functions in the QuickBasic language, not all functions are known to work correctly when used with the Intermec family of PC-compatible readers. Many of these have been tested, however, and are known to operate on the reader the same way as on a PC. These tested functions are listed below. Note: For a list of QuickBasic functions that are compatible with Visual Basic, see your Visual Basic manual.
Tested QuickBasic Functions $DYNAMIC Metacommand
COLOR Statement
DEFLNG Statement
$STATIC Metacommand
COM Statement
DEFSNG Statement
ABS Function
COMMON Statement
DEFSTR Statement
ABSOLUTE Keyword
CONST Statement
DIM Statement
AND Operator
COS Function
DO...LOOP Statement
ANY Keyword
CSNG Function
DOUBLE Keyword
APPEND Keyword
CSRLIN Function
DRAW Statement
AS Keyword
CVD Function
ELSE Keyword
ASC Function
CVSMBF Function
ELSEIF Keyword
ATN Function
CVDMBF Function
END Statement
BASE Keyword
CVI Function
ENVIRON Statement
Basic Character Set
CVL Function
ENVIRON$ Function
BEEP Statement
CVS Function
EOF Function
BINARY Keyword
DATA Statement
EQV Operator
BLOAD Statement
Data Type Keywords
ERASE Statement
Boolean Operators
DATE$ Function
ERDEV Function
BSAVE Statement
DATE$ Statement
ERDEV$ Function
CALL ABSOLUTE Statement
DECLARE Statement
ERL Function
CALL Statement
DEF FN Statement
ERR Function
CASE Keyword
DEF SEG Statement
ERROR Statement
CDBL Function
DEFDBL Statement
EXIT Statement
CHAIN Statement
DEFINT Statement
EXP Function
2-12
Page 39
QuickBasic Library
2
Tested QuickBasic Functions (continued) FIELD Statement
LINE (Graphics) Statement
ON Keyword
FILEATTR Function
LINE INPUT Statement
ON PLAY Statement
FILES Statement
LIST Keyword
ON TIMER Statement
FIX Function
LOC Function
ON...GOSUB Statement
FOR...NEXT Statement
LOCATE Statement
ON...GOTO Statement
FRE Function
LOF Function
OPEN Statement
FREEFILE Function
LOG Function
OPTION BASE Statement
FUNCTION Statement
LONG Keyword
OR Operator
GET (File I/O) Statement
LOOP Keyword
OUT Statement
GET (Graphics) Statement
LPOS Function
OUTPUT Keyword
GOSUB Statement
LPRINT Statement
PAINT Statement
GOTO Statement
LPRINT USING Statement
PEEK Function
HEX$ Function
LSET Statement
PLAY (Event Trapping) Statements
IF...THEN...ELSE Statement
LTRIM$ Function
PLAY (Music) Statement
IMP Operator
MID$ Function
PLAY Function
INKEY$ Function
MKD$ Function
PMAP Function
INP Function
MKDIR Statement
POINT Function
INPUT Statement
MKDMBF$ Function
POKE Statement
INPUT$ Function
MKI$ Function
POS Function
INSTR Function
MKL$ Function
PRINT Statement
INT Function
MKS$ Function
PRINT USING Statement
INTEGER Keyword
MKSMBF$ Function
PSET Statement
IS Keyword
MOD Operator
PUT (File I/O) Statement
KEY (Assignment) Statement
NAME Statement
PUT (Graphics) Statement
KEY (Event Trapping) Statement
NEXT Keyword
RANDOM Keyword
KILL Statement
NOT Operator
RANDOMIZE Statement
LBOUND Function
OCT$ Function
READ Statement
LCASE$ Function
OFF Keyword
REDIM Statement
LEFT$ Function
ON COM Statement
REM Statement
LEN Function
ON ERROR Statement
RESET Statement
LET Statement
ON KEY Statement
RESTORE Statement
2-13
Page 40
JANUS PSK for Basic Reference Manual
Tested QuickBasic Functions (continued) RESUME Statement
SYSTEM Statement
RETURN Statement
TAB Function
RIGHT$ Function
TAN Function
RMDIR Statement
THEN Keyword
RND Function
TIME$ Function
RSET Statement
TIME$ Statement
RTRIM$ Function
TIMER Function
RUN Statement
TIMER Statements
SCREEN Function
TO Keyword
SCREEN Statement
TROFF Statement
SEEK Function
TRON Statement
SEEK Statement
TYPE Statement
SELECT CASE Statement
UBOUND Function
SGN Function
UCASE$ Function
SHARED Statement
UNTIL Keyword
SHELL Statement
USING Keyword
SIN Function
VAL Function
SINGLE Keyword
VARPTR Function
SLEEP Statement
VARPTR$ Function
SOUND Statement
VARSEG Function
SPACE$ Function
VIEW PRINT Statement
SPC Function
VIEW Statement
SQR Function
WAIT Statement
STATIC Statement
WHILE...WEND Statement
STEP Keyword
WINDOW Statement
STOP Statement
WRITE Statement
STR$ Function
XOR Operator
STRING Keyword STRING$ Function SUB Statement SWAP Statement
2-14