Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 35 of 37

JANUS PSK for Basic, Version 2.1 Reference Manual, pages 341 to 350

Pages 341 to 350 of 362

The original document is the PDF (601 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec J2020, Intermec J2010 and Intermec J2050

Page 341

Appendix A: Status Codes

A

Subsystem 0400 DC (Decodes) (continued) Hex Code

Message

841C

Invalid row number

841D

Unable to scale counts

841E

Invalid 2 of 5 label

841F

Invalid 2 of 5 length

8420

2 of 5 label length exceeds maximum

8423

No valid label region found

8424

Ink spread exceeded threshold

8425

Denominator of an expression is zero

8426

Conversion to ASCII of full label failed

A-29

Page 342

JANUS PSK for Basic Reference Manual

Subsystem 0500 RW (Reader Wedge) Hex Code

Message

0500

Reader Wedge successful

0505

No reader commands parsed

0506

Valid reader commands parsed

0509

Accumulating reader command

050A

Reader command override

050B

Reader command enter accumulation

050C

Reader command exit accumulation

050D

Accumulating multiple-read labels

0510

An Enter reader command was parsed

0513

Protected field has been parsed

0517

Keycode label has been parsed

0518

An isolated Enter command was parsed

0519

A successful reader command parse on exit from accumulation

051A

A reader command has been successfully parsed when Enter is parsed

051C

An Enter Accumulate has been parsed when accumulating

051D

A label terminating a multiple-read sequence has been scanned

051E

A label beginning a multiple-read sequence has been scanned

0521

No communications status to report

0525

Reader commands forwarded to the application have been parsed

4502

Input timeout

4503

No input data

450E

The application should be notified

4529

Input from the source is other than the ones requested

452A

RWTSR is already loaded

452B

Prepare for reboot command received

452C

Cancel reboot command received

8501

Input request error

8504

Illegal reader commands parsed

8507

Reader commands parsing error

8508

Invalid configuration error

A-30

Page 343

Appendix A: Status Codes

A

Subsystem 0500 RW (Reader Wedge) (continued) Hex Code

Message

850F

Error in reader command edit

8511

Unable to allocate memory for input

8512

Protocol handler is not linked

8514

Reader command parse error on exit accumulation

8515

Application break detected

8516

Invalid Reader Wedge request

851B

A reader command has been erroneously parsed when Enter is parsed

851F

Label not accepted because the scan-ahead is not enabled and application is not at an input statement

8520

Reader Wedge link failed

8522

Invalid port specified in input request

8523

Communications error

8524

Communications error from an exit accumulation command

8526

Library coding error

8527

No symbology code available

8528

Bad parameter

A-31

Page 344

JANUS PSK for Basic Reference Manual

Subsystem 0600 CU (Communications) Hex Code

Message

0600

Communication operation success

0601

Communication buffer done

4600

Buffer canceled

4601

Communication timeout

4602

Communication had no client to cancel

4603

No protocol handler to configure

4604

Protocol handler is not yet loaded

4605

Protocol handler already receiving

4606

Protocol handler not active for link request

8600

Invalid configuration

8601

Buffer length zero error

8602

Communications port is in use

8603

Protocol error

8604

Communications port error

8605

Communications port is busy

8606

Communication request is not supported

8607

Protocol handler already loaded

8608

Protocol buffer error

8609

Unknown service request

860A

No data available

860B

Communication utility is not loaded

860C

Resume/suspend failure

860D

Communication utility INT 14 is already in use

860E

Incompatible revision between the protocol handler and the communication utility

860F

Invalid end of file character

8610

Buffer must be 256 bytes or greater

8611

Protocol handler not active

8612

Buffer size is too big

A-32

Page 345

Appendix A: Status Codes

A

Subsystem 0600 CU (Communications) (continued) Hex Code

Message

8613

Reentrant request for service

8614

Hardware I/O error

86F0

Nonsupported communication service

A-33

Page 346

JANUS PSK for Basic Reference Manual

Subsystem 0800 PM (Power Management) Hex Code

Message

0800

Power management success

8821

Cannot change state

8822

Invalid state manager command

8842

Invalid IPM interface command

8843

Parameter out of range

8844

Semaphore maximum exceeded

A-34

Page 347

Appendix A: Status Codes

A

Subsystem 0A00 TM (Timer) Hex Code

Message

0A00

Timer operation success

4A00

Timer not currently active

8A00

Invalid timer function code

8A01

No free timers available

8A02

Illegal timer mode specified

8A03

Timer not allocated

8A04

Timer is currently active

8A05

Invalid timer delay specified

8A06

Invalid timer ID specified

8A07

Timer resume/suspend failure

8A08

Timer utility cannot safely process user request

A-35

Page 348

JANUS PSK for Basic Reference Manual

Subsystem 0B00 BP (Beep) Hex Code

Message

0B00

Beeper call success

8B00

Pitch out of range

8B01

Duration out of range

8B02

Volume out of range

8B03

Not a sequential or a preemptive beep

8B04

Invalid battery flag

8B05

No preemptive timer available

8B06

No sequential timer available

8B07

Sequence empty

8B08

Beep sequence not started

8B09

Error initializing beep list

8B0A

Beep available list empty

8B0B

Bad beep manager request

8B0C

Beep sequence full

8B0D

Beeper in suspend state

8B0E

Beeper resume/suspend failure

A-36

Page 349

Appendix A: Status Codes

A

Subsystem 0E00 IM (Intermec Library) Hex Code

Message

0E00

String extract complete

0E01

String append complete

0E02

String search found

0E03

String copy complete

0E04

Successful operation

8E00

Substring not found

8E01

String extract empty

8E02

String extract too long

8E03

String append overflow

8E04

String search not found

8E05

String search empty

8E06

String search too long

8E07

String copy too long

8E08

Invalid parameter

8E09

Hex conversion length error

8E0A

Hex conversion overflow

8E0B

Invalid binary to ASCII radix

8E0C

Binary to ASCII field too small

A-37

Page 350

JANUS PSK for Basic Reference Manual

Subsystem 0F00 LG (Event Logger) Hex Code

Message

0F00

Successful logger operation

8F00

Event queue empty

8F01

Prohibited area disable

8F02

Reader service disable

8F03

Configuration management disable

8F04

Scanner disable

8F05

Decodes disable

8F06

Reader Wedge disable

8F07

Communications utility disable

8F08

Protocol handler disable

8F09

Power management disable

8F0A

BIOS disable

8F0B

Timer disable

8F0C

Beeper disable

8F0D

IRL desktop disable

8F0E

Prompting configuration disable

8F0F

Intermec library disabled

8F10

Event logger disable

8F11

Keyboard disable

8F12

System configuration disable

8F13

Keypad disable

8F14

Display disable

8F15

Communications manager disable

8F16

Workbench disable

8F17

Severity success disable

8F18

Severity warning disable

8F19

Severity error disable

8F1A

Severity fatal disable

8F1B

Wrong subsystem ID entered

8F1C

Wrong severity ID entered

A-38